Getting Started with i50
24
Switch on the receiver and connect it with a computer by USB Cable. After the
successful connection, a removable disk named as the Serial Number (SN) of the
receiver will appear on the computer.
Double click the removable disk and you will see the folder named as “repo”.
Double click this folder, you will see 9 folders. The “push_log” folder is used to
save the log files, and the other 8 folders represent different logging session and
are used for store static data.
Double click the folder that you have configured to store the static data, you will
see the folder(s) created by the i50 system automatically and named by the date
which is decide by GPS time when you start to log data.
Select the destination folder and double click it, and then two folders named as
different data format (hcn and rinex) will be displayed.
Select the data format that you has configured to save the static data, you will find
the static raw data.
Tip – For hcn files, the name of the file is represented as XXXXXXDDDNN, where
XXXXXX is the SN of the receiver, DDD is day of year, and NN is the recording session.
WARNING – The static data will be saved in the first logging session, the
“record_1” folder, by default. Old files will be deleted if the storage space is full. If you
configure not to auto delete old files when the memory is low, the receiver will stop
data logging.