35
long and exceed 15s.
Non Contact Voltage Detection (NCV)
3.10.
The NCV mode detects only AC voltages connected to the network with
respect to ground. Always check for the presence of a voltage with a voltage
measurement. To measure the absence of a voltage, use a VAT
(
Network : 230V only, 50 Hz (sensitivity : 10 mV)
The meter can detect AC live voltage without contact.
The NCV detection zone is displayed on the sheath.
1.
Remove all test leads from the Meter
2.
Turn the rotary switch to
3.
Approach live conductor from LCD (position
of the Meter may affect measurement)
If no AC live voltage is detected the Meter will
display EF and product will be silent.
If AC live voltage is detected product will show 4
different levels:
from - to ----, at
– buzzer will sound discontinuously,
at ---- buzzer will sound continuously, and backlight will
blink red. Basic detection voltage is for 220/230V.
NCV is only for indication purpose and shouldn't be
used for measurement, or to detect the absence of
voltage.
The NCV mode has an indicative meaning only and must not be used either for
measuring nor detect the absence of voltage.
An engraved marking on the sheath indicates the position of the antenna for NCV
indication.
Содержание Metrix MTX204
Страница 2: ...FR 1 GB 22 DE 42 IT 63 ES 83 CZ 104 NL 125 PL 146 RO 167 RU 188 ANNEX 210...
Страница 7: ...5 Description 2 4...
Страница 28: ...26 Device description 2 4...
Страница 48: ...46 Beschreibung 2 4...
Страница 69: ...67 Descrizione 2 4...
Страница 89: ...87 Descripci n 2 4...
Страница 110: ...108 bezkontaktn detekce nap t Popis p stroje 2 4...
Страница 131: ...129 Beschrijving 2 4...
Страница 152: ...150 Opis 2 4...
Страница 173: ...171 Descriere 2 4...
Страница 191: ...189 1 MTX 204 1 1 600 IV 1000 III 61010 2 033 61010 031 61010 2 032 1 1 1 DEEE 2002 96 CE...
Страница 192: ...190 FUSED 1 1 2 IV III II...
Страница 193: ...191 2 2 1 2 AA 1 5 1 5 1 5 2 2 III IV www chauvin arnoux com 2 3 MTX 204...
Страница 194: ...192 2 4...
Страница 195: ...193 1 2 5 2 Range 3 4 HOLD NCV 5 REL 6 Hz 7 Max Min 8 Commutateur 9 10 10 11 12 600...
Страница 196: ...194 2 5 1 8 A 2 9 3 10 4 11 5 12 6 13 7...
Страница 197: ...195 2 6 1 2 Multifix P01102100Z 3 4 2 3 4...
Страница 198: ...196 3 3 1 61010 31...
Страница 199: ...197 3 2 1 2 2 1 5 3 OL V 3 3 2 2 NCV...
Страница 200: ...198 AUTO Range 3 4 1 10 500 2 VlowZ 3 COM 4 500 600 Range 60...
Страница 201: ...199 3 5 1 2 3 A mA A COM 4 5 10A 10A 630 MTX 204 10 A MTX 204 3 6...
Страница 202: ...200 1 2 COM 3 50 600 OL 3 7 600 OL 3 8...
Страница 203: ...201 1 2 3 4 5 3 OL 3 9 1 2 COM 3...
Страница 204: ...202 4 5 100 15 NCV 3 10 NCV www chauvin arnoux com 230 50 10 NCV 1 2 3 EF 4 220 230 50...
Страница 205: ...203 NCV NCV 3 11 VlowZ 500 3 12 REL VLowZ Hz Hz 1 Max Min Max Min Max Min...
Страница 206: ...204 4 23 C 3 C 45 75 1 5 AA Ni MH 45 65 40 1...
Страница 210: ...208 6 6 1 OFF 6 2 10A OFF 1 2 3 A mA A 4 A 000 0 000 2...
Страница 211: ...209 5 OL 6 6 3 LR6 F1 630 1000 10 6 3 32 F2 10 1000 30 10 38 7...
Страница 214: ...212 X04836A00 Ed 02 10 2018...