41
2.
The
key can be pressed to display the frequency of the order of
harmonic concerned ;
3.14 RECORDING OF MEASUREMENT DATA/CAMPAIGNS
The device allows recording of the data/measurements acquired, using the REC
function. The default recording interval is 60 seconds. It can be set to from 1
second to 600 seconds (10 minutes) in set-up (see §3.4.3).
1.
In the function being measured, apply a long press (> 2s) to the
key. The
REC
symbol is displayed. Recording of the measurements
starts. The data recorded are in the format: "MAX value – AVG Value
– MIN Value – Unit – Mode" (AC, DC, or AC+DC)
2.
To stop recording, apply a long press (>2s) to the
key. The
REC
symbol disappears.
Caution :
THD recording minimum time interval is 2 s.
Remarks :
recording is interrupted automatically when the memory of the device is
full (REC symbol is flashing) or Bluetooth wireless communication is activated
(§
Содержание F407
Страница 1: ...F407 Clamp multimeter GB User s manual...
Страница 48: ...48 In the Mat rial folder the port COM number dedicated to the device is displayed COM18 in the example...
Страница 50: ...50 Validate by choosing Close...
Страница 53: ...53 3 5 Graph mode enlarged zoomed...
Страница 74: ...693111A02 Ed 7 09 2016...