![Chauvin Arnoux C.A 6115N Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/chauvin-arnoux/c-a-6115n/c-a-6115n_user-manual_2594579034.webp)
34
Maximum loop impedance authorised for different protective devices, according to table A1 of
the DIN VDE 100 standard, part 610 (example).
U
0
=
Low voltage fuse as per
Circuit-breaker as per
Circuit-breaker
220 V
DIN standard VDE 0636
DIN standard VDE 0641
with characteristics
4)
with characteristic L
1), 2), 3)
In
Ia (5 s)
Zs (5 s)
Ia (0.2 s)
Zs (0.2 s)
5 In
Zs (
≤
0.2 s)
15 In
Zs (
≤
0.2 s)
(A)
(A)
(
Ω
)
(A)
(
Ω
)
(A)
(
Ω
)
(A)
(
Ω
)
2
9.21
23.9
20
11.0
10
22
30
7.3
4
19.2
11.5
40
5.5
20
11
60
3.7
6
28
7.9
60
3.7
30
7.3
90
2.4
10
47
4.7
100
2.2
50
4.4
150
1.5
16
72
3.1
148
1.5
80
2.8
240
0.9
20
88
2.5
191
1.2
100
2.2
300
0.7
25
120
1.8
270
0.8
125
1.8
375
0.6
32
156
1.4
332
0.7
160
1.4
480
0.5
35
173
1.3
367
0.6
175
1.3
525
0.4
40
200
1.1
410
0.5
200
1.1
600
0.37
50
260
0.8
578
0.4
250
0.9
750
0.29
63
351
0.6
750
0.3
315
0.7
945
0.23
80
452
0.5
-
-
400
0.6
1200
0.18
100
573
0.4
-
-
500
0.5
1500
0.15
125
751
0.3
-
-
625
0.4
1875
0.12
160
995
0.2
-
-
800
0.3
2400
0.09
1) Characteristic G as per CEE 19/1 publication
2) Characteristic K as per DIN VDE 0660 part 101
3) Characteristic U as per CEE 19/2 publication
4) Nominal voltage of conductor in relation to earth