background image

 
5. Appendix 

5/7/2010 1:21 PM 

3.

 

S

ETUP

 

 

AC Power 

This fixture runs on 100~240 VAC, 50/60 Hz. Before powering on the unit, make sure the line voltage 
to which you are connecting it is within the range of accepted voltages. 

 

Always connect the fixture to a switched circuit. Never connect the fixture to a rheostat 
(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used only as a 0 
to 100% switch.

 

To determine the power requirements for a particular fixture, see the label affixed to the back plate of 
the fixture or refer to the f

ixture’s specifications chart. A fixture’s listed current rating indicates its 

average current draw under normal conditions.  

Always connect the fixture to a circuit with a suitable electrical ground. 

 

 

 

 

Fuse Replacement 

1. 

With a Philips #2 screwdriver unscrew the fuse holder out of its housing.  

2. 

Remove the damaged fuse from its holder and replace with exact same type fuse.  

3. 

Insert the fuse holder back in its place and reconnect power.  

 
 
 
 
 

See the “Technical Specifications” section for the fuse size. 

 
 

 

Disconnect the power cord before replacing a fuse and always 
replace with the same type fuse. 

The fuse is 

located here 

Содержание Work Light

Страница 1: ... 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com User Manual Snapshot Use on Dimmer Outdoor Use Sound Activated DMX Master Slave Auto ranging Power Supply Replaceable Fuse User Serviceable Duty Cycle ...

Страница 2: ...IN 3 WHAT IS INCLUDED 3 UNPACKING INSTRUCTIONS 3 MANUAL CONVENTIONS 3 ICONS 3 SAFETY INSTRUCTIONS 4 2 INTRODUCTION 5 FEATURES 5 FEATURES FOOTSWITCH 5 PRODUCT OVERVIEW 6 3 SETUP 7 AC POWER 7 FUSE REPLACEMENT 7 Orientation 8 Rigging 8 Tripod Stand 9 4 OPERATING INSTRUCTIONS 10 FOOTSWITCH OPERATION 10 Auto 10 Blackout 10 Sound 10 5 APPENDIX 11 GENERAL MAINTENANCE 11 GENERAL TROUBLESHOOTING 12 CONTACT...

Страница 3: ...entiate certain types of information from the regular text CONVENTION MEANING 10 A DIP switch to be configured Menu A key to be pressed on the fixture s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the operating mode current status MENU Settings A sequence of menu options to be followed ON ...

Страница 4: ...ct from power source before servicing or replacing fuse and be sure to replace with same fuse source Secure fixture to fastening device using a safety chain Maximum ambient temperature Ta is 104 F 40 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by un...

Страница 5: ...hts Safely mounts to truss with clamps Independent positioning of each light Low profile lights are 1 2 in deep Adjustable stand from 54 in to 85 in Built in automated programs Built in sound activated programs Features footswitch Trigger built in static or automated programs includes RGB fades Instantly triggers sound active mode Instantly blackout any program ...

Страница 6: ...ntroduction 6 5 7 2010 1 21 PM Product Overview Lights 4 Mini 4BAR Carrying Case Tripod Stand Foot Switch Tripod Stand Securing Knob Microphone Sensitivity Adjustment Knob Fuseholder Microphone Back Panel ...

Страница 7: ...ee the label affixed to the back plate of the fixture or refer to the fixture s specifications chart A fixture s listed current rating indicates its average current draw under normal conditions Always connect the fixture to a circuit with a suitable electrical ground Fuse Replacement 1 With a Philips 2 screwdriver unscrew the fuse holder out of its housing 2 Remove the damaged fuse from its holder...

Страница 8: ...bs and tilting the fixture After finding the desired position retighten both knobs o When selecting installation location take into consideration access and routine maintenance o Never mount in places where the fixture will be exposed to rain high humidity extreme temperature changes or restricted ventilation o The clamps for hanging are sold separately o When using the clamp hanging bolts BOTH of...

Страница 9: ...nd 6 After confirming that the Safety Pin is removed carefully and slowly loosen the Height Adjustment Knob to allow the height of the stand to be increased The top of the stand may drop quickly so be careful to control this and be aware of personal safety 7 Raise the stand to the desired height and hand tighten the Height Adjustment Knob Then insert the Safety Pin to secure the height of the stan...

Страница 10: ...1 2 simultaneously to activate sound operation PEDAL SUB OPTION FUNCTION 1 PRESET 1 x press Auto program color change 2 x press Auto program color fade 3 x press Red 4 x press Green 5 x press Blue 6 x press Cyan 7 x press Magenta 8 x press Yellow 9 x press White 2 BLACKOUT Blackout The fixture will start up in sound mode when first powered ON The fixture will cycle through the auto programs and st...

Страница 11: ...when the fixture is cold with a mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue Apply solution to the cloth or tissue and drag dirt and grime to the outside of the lens Gently polish optical surfaces until they are free of haze and lint The cleaning of external optical lenses and or mirrors must be carried out periodically to optimize light outp...

Страница 12: ...ntroller Loose DMX cables Check cable connections Faulty DMX interface Replace DMX input Faulty Main PCB Replace Main PCB Loss of signal Bouncing signals Install terminator as suggested Long cable Low level signal Install amplifier right after fixture with strong signal Interference from AC wires Keep DMX cables separated from power cables or black lights If you still have a problem after trying t...

Страница 13: ... UPS packing or double boxing is always a safe method to use CHAUVET reserves the right to use its own discretion to repair or replace product s If you are given an RMA please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 The RMA 5 A brief description of the symptoms Claims Damage incurred in shipping is the responsibility of ...

Страница 14: ... tripod stand 16 9 lbs 7 7 kg POWER Auto ranging power supply 100 240 VAC 50 60 Hz Power consumption 120 VAC 60 Hz 34 W 0 5 A max 0 2 A inrush Power consumption 230 VAC 50 Hz 34 W 0 3 A max 0 2 A inrush Fuse F 1 A 250 V LIGHT SOURCE LED 300 75 per light 100 red 100 green 100 blue 100 000 hrs PHOTO OPTIC Beam Angle 16 Field Angle 26 Intensity 1 160 lux THERMAL Maximum ambient temperature 104 F 40 C...