Operation
WELL™ Quad-M User Manual
-17-
Program Upload
This option allows you to duplicate the custom programs of a product onto another
product using the Master/Slave mode.
1. Configure and connect the products in a Master/Slave arrangement, where the
master product has the custom programs you want to transfer to the slave products.
2. From the master product, go to the
SET
main level.
3. Select
UPLD
.
4. When
PASS
shows, press
<ENTER>
.
5. Enter the master access password (see
Control Panel Lock
).
6. When
SEND
shows, press
<ENTER>
to start the upload.
7. Wait for the upload process to finish (the display will show
OK
before continuing or
turning the products off.
The Master/Slave products will provide the status of the process by lighting up as
follows:
•
Yellow indicates that the upload process is running.
•
Green indicates that the upload process completed successfully.
•
Red indicates that the upload process failed due to an error. Recheck all cable
connections and restart the process. If the issue persists, contact CHAUVET®
Technical Support.
Do not upload the data from a WELL™ Quad-M to a different product, as the other
product may become inoperative.
Resetting Factory
Defaults
This setting allows you to reset the product’s default values, including the custom
programs.
1. Go to the
SET
main level.
2. Select
REST
.
3. When
PASS
shows, press
<ENTER>
.
4. Enter the master access password (see
Control Panel Lock
).
5. Wait for the reset process to finish.
Resetting Calibration
Defaults
This setting allows you to reset the product’s default values of the color macros in
Whites
Setting
or
Whites Calibration
.
1. Go to the
CAL
main level.
2. When
PASS
shows, press
<ENTER>
.
3. Enter the master access password.
4. Go to
CALR
.
5. When
PASS
shows, press
<ENTER>
.
6. Enter the master access password.
Setting the
White Color
This setting allows you to select and edit the temperature of the white colors used in
channel 6 when in the
TOUR
mode or channel 11 when in
TR16
mode.
1. Go to the
CAL
main level.
2. Enter the master access password as described in
Control Panel Lock.
3. Go to
CAL1
.
4. Select a white color (
WH.01~11
).
5. Select a color (
RED
,
GREN
,
BLUE
, or
AMBR
).
6. Select a color value (
000~255
).
7. Repeat for the other colors.
Содержание Well Quad-M