13:31 

Hanging Clamp 

3. Setup 

AC Power 

Warning! 

Verify that the power requirement label on your unit matches the line voltage 
applied. All fixtures must be connected to circuits with a suitable Earth Ground. 

 

  To determine the power requirements for a particular fixture, see the label affixed to the back plate 

of the fixture or refer to the fixture’s specifications chart.  

  A fixture’s listed current rating is its average current draw under normal conditions.  

  All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat 

(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% 
to 100% switch.  

  Before applying power to a fixture, check that the source voltage matches the fixture’s 

requirement.  

  All fixtures must be connected to circuits with a suitable Earth Ground.  

P o w e r   C a b l e   C o n f i g u r a t i o n  

 

 

Mounting 

O r i e n t a t i o n  

This fixture can be mounted on a truss using a clamp in any position. 

R i g g i n g  

The fixture includes a mounting yoke to which 1 rigging clamp can 

be bolted. You must supply your own clamp and make sure the 

clamp is capable of supporting the weight of this fixture. You can 

order C-clamps from any CHAUVET dealer or distributor. 

1.  Block access below the work area and use suitable and stable 

platform when installing or servicing fixture. 

2.  Align the clamp screw with the center hole on the yoke and tighten. 

3.  Verify the structure can hold 10 times the weight of all to-be installed fixtures. 

4.  Adjust the angle on the yoke arm as necessary. 

5.  Always use a safety cable or chain as a secondary source of attachment. The safety cable must 

hold 10 times the weight of the fixture. If safety cable attachment point is provided that is 

permanently affixed to the surface or body of the fixture, use that instead of looping through a 

hanging yoke/arm. 

 

C

ABLE

 

Pin

 

International

 

Screw Color

 

B

ROWN

 

Live 

Yellow or Brass 

B

LUE

 

Neutral N 

Silver 

Y

ELLOW

/G

REEN

 

Earth 

EG (Ground) 

W

Green 

Содержание Thruster

Страница 1: ...CHAUVET 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2006 10 10 13 31 Thruster ...

Страница 2: ...TTING UP A DMX SERIAL DATA LINK 9 STANDALONE MASTER SLAVE FIXTURE LINKING 9 4 OPERATING INSTRUCTIONS 10 STANDALONE MODE 10 Single Fixture Mode 10 Master Slave Mode 10 Setup Master Fixture 10 Setup Slave Fixtures 11 Sample Master Slave Setup and Linking Visual Guide 11 Table of DIP switch Settings Options Patterns 12 Table of DIP switch Settings for Fixture Values 12 DMX CONTROL MODE 13 Configuring...

Страница 3: ...e factory it is important that the fixture be returned in the original factory box and packing Note If you should require sending any items back to CHAUVET call CHAUVET for a RMA Return Merchandise Authorization number The factory will not allow any shipments without an RMA Your shipment includes the following 1 x Thruster Strobe Tube Warranty Card Users Manual Contact Us World Wide General Inform...

Страница 4: ... Using the wrong type of lamp in this product VOIDS the warranty Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture The unit must be installed in a location with adequate ventilation at least 50cm from adjacent surfaces Be sure that no ventilation slots are blocked Maint...

Страница 5: ...ith linking output for runway effect Automatic built in programs with sound activation Sound active stand alone mode via DMX Flash speed control Built in programs via DMX Selectable flash patterns with or without DMX controller Runway effect with or without DMX controller Built in automated programs with master slave Built in sound activated programs with master slave Fan cooled DMX Channel Summar...

Страница 6: ... Power Switch Speed Rotary knob Audio Sensitivity Rotary knob POWER MIC ON OFF POWER IN DMX IN DMX OUT LINK OUT For thruster only must assign unit a number 1 2 4 8 16 1 2 4 8 16 32 64 128 256 AUDIO SPEED UNIT ASSIGN DMX ADD AS IGN S TM CAUTION Running the Thruster Strobe Tube at full speed for durations exceeding one hour can significantly decrease the life of your lamps Product Overview ...

Страница 7: ...ration Mounting Orientation This fixture can be mounted on a truss using a clamp in any position Rigging The fixture includes a mounting yoke to which 1 rigging clamp can be bolted You must supply your own clamp and make sure the clamp is capable of supporting the weight of this fixture You can order C clamps from any CHAUVET dealer or distributor 1 Block access below the work area and use suitabl...

Страница 8: ... If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DMX Data Cable Use a Belden 9841 or equivalent cable which meets the specifications for EIA RS 485 applications Standard microphone cables cannot transmit DMX data reliably over long distances The cable will have the following characteristics ...

Страница 9: ...d Shield Pin 1 Pin 1 Data signal Pin 2 Pin 2 Data signal Pin 3 Pin 3 Do not use Do not use Do not use Do not use Setting up a DMX Serial Data Link 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the controller 2 Connect the end of the cable coming from the controller which will have a female 3 pin connector to the input connector of the next fixture...

Страница 10: ...a link without the use of a controller In a master slave operation the slave fixtures will synchronize and will behave either identically or in a planned chase pattern to the master unit which must be the first in the serial daisy chain A Master Slave Thruster system can consist of up to 31 total fixtures Setup Master Fixture 1 Set DMX ADD ASSIGN DIP switch 10 to the On position and all others to ...

Страница 11: ...re DIP switches 1 5 are used to select the running built in pattern for the entire system NOT to address the fixture like in the slave fixtures following In this instance refer to the Table of DIPswitch settings in the page following to choose a programmed pattern The master fixture defaults to Fixture address 1 DIP switches 1 5 are used to set the total number of fixtures in the system DIPswitch ...

Страница 12: ...r 0 1 0 1 0 0 0 0 0 1 10 Flow from two ends to center 1 0 1 0 0 0 0 0 0 1 11 All flash 1 1 1 1 0 0 0 0 0 1 Table of DIP switch Settings for Fixture Values Use the following table to quickly set the UNIT ASSIGN DIP switch on the Master unit with the total number of fixtures in your Master Slave setup and to address each Slave fixture accordingly using the DMX ADD ASSIGN DIP switches DIP switch Sett...

Страница 13: ...pear consistent and organized Up to 31 Thrusters can be controlled as One Device Configuring Thrusters for Individual DMX control 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the controller 2 Connect the end of the cable coming from the controller which will have a female 3 pin connector to the input connector of the next fixture consisting of a ...

Страница 14: ...hannels of DMX and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 105 and 106 Choose start addresses so that the channels used do not overlap and notate the start address selected for future reference If this is your first time read the DMX Primer in the Appendix Section DMX Input 1 2 3 4 5 6 7 8 9 10 1 2 4 8 16 1 2 4 8 16 32 64 128 256 UNIT ASSIGN DMX ...

Страница 15: ...sitive S CHAUVET carries 3 pin XLR DMX compliant cables DMX 10 33 DMX 4 5 15 and DMX 1 5 5 Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RA Products returned without an RA will be refused Call CHAUVET and request RA prior to shipping the fixture Be p...

Страница 16: ...ning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Binary DMX DIP switch Addressing Each DIP switch has an associated value Adding the value of each switch in the ON position will provide the final address Determining which switches to toggle ON given a specific desired address or value can be accomplished ...

Страница 17: ...6 268 300 332 364 396 428 460 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 1...

Страница 18: ...255 Program Speed Speed Slow Ù Fast Technical Specifications WEIGHT DIMENSIONS Length 1003 mm 39 5 in Width 76 mm 3 0 in Height 229 mm 9 0 in Weight 5 22 Kgs 11 5 lbs Master Pack 2 pcs 10 66 Kgs 23 5 lbs POWER Operating Voltage 115V 60 Hz AC input IEC 60320 C14 European version 240V 50 Hz Current draw peak 15W 120V FUSE Main 20mm Glass 5A Fast Blow CONTROL PROGRAMMING Data input locking 3 pin XLR ...

Отзывы: