Chauvet Stepper Скачать руководство пользователя страница 1

Snapshot

Ok on Dimmer 

Outdoor OK 

Sound Activated 

DMX/Master/Slave

115V/230V Switch 

Replaceable Fuse 

User Serviceable 

Stepper™

USER MANUAL

Chauvet, 3000 N 29

th

Ct, Hollywood, FL 33020 U.S.A. 

(800) 762-1084 . (954) 929-1115 

FAX (954) 929-5560 

www.chauvetlighting.com 

Содержание Stepper

Страница 1: ...door OK Sound Activated DMX Master Slave 115V 230V Switch Replaceable Fuse User Serviceable Stepper USER MANUAL Chauvet 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com ...

Страница 2: ...SE REPLACEMENT 7 4 OPERATING INSTRUCTIONS 8 OPERATING MODES 8 Stand Alone 8 Master Slave 8 MASTER SLAVE SETTINGS 8 DMX Mode 8 SETTING THE STARTING ADDRESS 9 5 APPENDIX 10 DMX PRIMER 10 Fixture Linking 10 DMX QUICK REFERENCE CHART 11 DMX CHANNEL VALUES 12 MAINTENANCE 12 GENERAL TROUBLESHOOTING 13 TROUBLESHOOTING 14 RETURNS PROCEDURE 14 CLAIMS 14 TECHNICAL SPECIFICATIONS 15 Stepper User Manual 2 200...

Страница 3: ...de for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet x Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture x To prevent risk of fire or shock do not expose fixture to rain or moisture Make sure there are n...

Страница 4: ...ted programs via master slave or DMX x Built in sound activated programs via master slave or DMX Additional Features x 40 white lenses with a 4 color drum that rotates and shakes x Linkable with Kinta Oceana x Automatically enters stand alone when no DMX signal is present x Fan cooled DMX Channel Summary Channel Function 1 Rotate 2 Strobe Stepper User Manual 4 2006 12 12 09 53 ...

Страница 5: ...r Connector Fuse Compartment Chassis Ground DMX Input Connector DMX Output Connector Sound Sensitivity Wired Remote Built in Microphone AC Voltage Switch Safety Hook DMX Channel Select Hanging Bracket Stepper User Manual 5 2006 12 12 09 53 ...

Страница 6: ... handling with bare hands may result in premature lamp failure or fire Lamp Cover Screws Lamp Replacement 1 Remove the two lamp cover screws located on the top of the fixture as indicated in Figure 1 2 Place the lamp base plate on the fixture as indicated in Figure 2 3 The lamp is held in place by tension provided by springs inside of the ceramic socket It is important to proceed with lamp removal...

Страница 7: ...ocation take into consideration lamp replacement access and routine maintenance x Safety cables should always be used x Never mount in places where the fixture will be exposed to rain high humidity extreme temperature changes or restricted ventilation Fuse Replacement 1 Disconnect the power cord 2 With a flat head screwdriver wedge the fuse holder out of its housing 3 Remove the damaged fuse from ...

Страница 8: ...ecting the Stepper for Master Slave operation does not require any menu or setting selections Simply connect each unit in a daisy like fashion using qualified 3 pin DMX cables as described below MASTER SLAVE SETTINGS 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the first fixture 2 Connect the female end of the cable coming from the first fixture ...

Страница 9: ...ermine the largest value switch that is less than the start address Turn this switch on 2 Subtract the value of the switch you just turned on from the starting address number 3 Determine the largest value switch that is less than the remainder from the previous subtraction Turn this switch on 4 Subtract the value of the switch you just turned on from the remainder of the previous subtraction 5 Rep...

Страница 10: ...of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with 3 pin XLR male to female connectors The shield connection is pin 1 while pin 2 is Data Negative S and pin 3 is Da...

Страница 11: ... 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 18 50 82 114 146 178 210 242 274 306 338 370 402 434 466 ...

Страница 12: ...nents Clean all glass when the fixture is cold with a mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue Apply solution to the cloth or tissue and drag dirt and grime to the outside of the lens Gently polish optical surfaces until they are free of haze and lint Do not to touch the lamp glass when cleaning fixture Oil and dirt can cause damage and p...

Страница 13: ...adically Possible bad lamp or fixture is overheating Lamp may be at end of its life 9 Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again wait 5 to 10 minutes before powering up 9 Loss of signal Use only DMX cables Install terminator Note Keep DMX cables separated from power cables or black light...

Страница 14: ...e packaging is the customer s responsibility CHAUVET reserves the right to use its own discretion to repair or replace product s As a suggestion proper UPS packing or double boxing is always a safe method to use Note If you are given an RA please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 The RA 5 A brief description of the...

Страница 15: ...V Inrush current 1 276W 120V LAMP CH64535 650W 120V CH64540 650W 230V THERMAL Maximum ambient temperature 104 F 40 C FUSE Main 20mm Glass 7A Fast Blow 250V CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield ground pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 2 ORDERING INFORMATION Stepper STEPPER Blackout...