3.

 

S

ETUP

 

 

 

AC Power 

This  product  has an auto-ranging power supply and it can work with an input voltage 
range of 100~240 VAC, 50/60 Hz. 

To determine the power requirements for this product (circuit breaker, power outlet, and 
wiring),  use the current value listed on  the label affixed to the product’s back panel, or 
refer to the product’s specifications chart. The  listed current rating indicates the 
product’s average current draw under normal conditions. 

 

 

 

Always connect this  product  to a protected circuit (circuit breaker or fuse), 
making sure that it has an appropriate electrical ground to avoid the risk of 
electrocution or fire. 

 

 

 

Never connect this product to a rheostat (variable resistor) or dimmer circuit, even 
if the rheostat or dimmer channel serves only as a 0 to 100% switch. 

 

 

Fuse 

Replacement

 

Follow the instructions below to change the fuse in the control box, if necessary.

 

 

 

 

Disconnect this product from the power outlet before replacing the fuse. 

 

 

 

1.  Wedge the tip of a flat-head screwdriver into the slot of the fuse holder and pry out of 

its housing. 

2.  Remove the blown fuse from its holder and replace with a fuse of the exact same 

type and rating.  

3.  Insert the fuse holder back into place, and reconnect power. 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

This product ships with no spare fuse. The safety cap does have room for a spare.  

 

 

 

Always replace a blown fuse of the same type and rating. 

 

 

 

 

Installed fuse  

(held by plastic clip) 

Spare fuse holder  

(inside safety cap) 

Safety cap 

Содержание Motion Facade LED

Страница 1: ...User Manual...

Страница 2: ...oduction 5 Product Overview 5 Product Dimensions 5 3 Setup 6 AC Power 6 Fuse Replacement 6 Mounting 7 Orientation 7 Rigging 7 4 Operation 8 Control Panel Operation 8 Menu Map 8 Configuration DMX 8 Sta...

Страница 3: ...12 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified Menu Settings A sequence of menu options to be followed ENTER A key to be pressed o...

Страница 4: ...t the voltage of the outlet to which you are connecting this product is within the range stated on the decal or rear panel of the product This product is for indoor use only IP20 To prevent risk of fi...

Страница 5: ...onFa ade LED User Manual Rev 6 Page 5 of 13 2 INTRODUCTION Product Overview Product Dimensions Front Panel Button Menu LED Display Top Panel Curtain Input Power In Fuse holder On Off Switch DMX Out DM...

Страница 6: ...the risk of electrocution or fire Never connect this product to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel serves only as a 0 to 100 switch Fuse Replacement...

Страница 7: ...to access the unit for maintenance and programming purposes Make sure that the structure onto which you are mounting this product can support its weight Please see the Technical Specifications sectio...

Страница 8: ...the auto mode program runs Program 1 30 NO Disables numbered program running in sequence in auto or sound mode YES Enables numbered program running in sequence in auto or sound mode Configuration DMX...

Страница 9: ...e may transmit DMX signals that could interfere with the DMX signals from the controller Sound Active Mode To enable the Sound Active mode do the following 1 Press MENU repeatedly until Sound shows on...

Страница 10: ...ack 096 111 Multi Color Freeway 112 127 Color Wave L R 128 143 Color Wave R L 144 159 Color Bar Chase L R 160 175 Color Bar Chase R L 176 191 Windmill 192 207 Fan 208 223 Whirlpool 224 239 Falling Sno...

Страница 11: ...LED controller not powered Check power to the MotionFa ade LED controller Faulty DMX cable Repair or replace faulty cable Breaker Fuse keeps blowing Excessive circuit load Check total load placed on...

Страница 12: ...t Power Power Supply Type Range Voltage Selection Switching internal 100 240 V 50 60 Hz Auto ranging Parameter 120 V 60 Hz 230 V 50 Hz Consumption 21 W 23 W Operating 0 2 A 0 1 A Fuse F 2 A 250 V F 2...

Страница 13: ...he U S United Kingdom or Ireland contact your distributor of record and follow their instructions on how to return CHAUVET products to them Visit our website for contact details Returns Call the corre...

Отзывы: