background image

 

3000 N 29

th

 Ct, Hollywood, FL 33020 U.S.A.  

(800) 762-1084 – (954) 929-1115 

FAX (954) 929-5560 

www.chauvetlighting.com

 

 

 

 

 

 

 

 

 

 

 

User Manual 

 

Snapshot

Use on Dimmer 

 

Outdoor Use 

 

Sound Activated 

 

DMX 

 

Master/Slave 

 

115 V / 230 V Switchable 

 

Replaceable Fuse 

 

User Serviceable 

 

Duty Cycle 

 

Содержание MiN Spot RGBW

Страница 1: ...L 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com User Manual Snapshot Use on Dimmer Outdoor Use Sound Activated DMX Master Slave 115 V 230 V Switchable Replaceable Fuse User Serviceable Duty Cycle ...

Страница 2: ...ion 8 Rigging 8 4 OPERATING INSTRUCTIONS 9 CONFIGURING THE STARTING ADDRESS 9 CONTROL PANEL FUNCTIONS 9 MENU MAP 10 DMX OPERATION 11 MASTER SLAVE 11 STANDALONE OPERATION 12 Master Slow 12 Master Fast 12 Master Sound 12 EASY CONTROLLER CA 9 13 Fixture Settings 13 Operation 13 Fixture Linking 14 MANUAL FOCUS ADJUSTMENT 15 DMX CHANNEL VALUES 16 5 APPENDIX 18 DMX PRIMER 18 GENERAL MAINTENANCE 18 DATA ...

Страница 3: ...in types of information from the regular text CONVENTION MEANING 10 A DIP switch to be configured Menu A key to be pressed on the fixture s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the operating mode current status MENU Settings A sequence of menu options to be followed ON A value to be...

Страница 4: ...ct from power source before servicing or replacing fuse and be sure to replace with same fuse source Secure fixture to fastening device using a safety chain Maximum ambient temperature Ta is 104 F 40 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by un...

Страница 5: ...r mixing and color macros Built in movement macros via DMX Built in automated programs via master slave or DMX Built in sound activated programs via master slave or DMX Additional Features Quad color LED for superior color mixing 3 600 mA total Linkable with Min Wash RGBW in stand alone User selectable basic or advanced operating modes User selectable pan tilt ranges Pan 540 360 180 Tilt 270 180 9...

Страница 6: ...Introduction 6 6 14 2010 4 13 PM Product Overview Control Panel Light Output Fuseholder 115 V 230 V switch Remote control in Easy Controller DMX in DMX out Rubber Feet Focus Adjustment Back Panel Power in ...

Страница 7: ...e rheostat or dimmer channel is used only as a 0 to 100 switch To determine the power requirements for a particular fixture see the label affixed to the back plate of the fixture or refer to the fixture s specifications chart A fixture s listed current rating indicates its average current draw under normal conditions Always connect the fixture to a circuit with a suitable electrical ground Fuse Re...

Страница 8: ...following steps for installation 1 There are 2 screws that are used to attach the hanging bracket to the base of the fixture Use a 5 mm Allen wrench to install These should be hand tightened and installed at the bracket attachment points 2 2 Install the safety attachment bolt to the base of the fixture in the location shown below This should be hand tightened 3 Mount the fixture securely This may ...

Страница 9: ... The MiNSpot RGBW fixture uses up to 14 DMX channels If this is your first time using DMX we recommend reading the DMX Primer section in the Appendix Control Panel Functions Access control panel functions using the four buttons located directly underneath the LED display on the control panel The Control Panel shows the current state of the unit It is used to select the operating mode as well as th...

Страница 10: ...nnel Configuration 14CH 14 channel DMX operating mode with 16 bit pan tilt master dimmer preset color macros and RGBW color mixing 6CH 6 channel DMX operating mode with 8 bit pan tilt master dimmer and preset color macros Pan Range PA54 Select the maximum range of movement for the pan 540 360 180 degrees PA36 PA18 Tilt Range ti27 Select the maximum range of movement for the tilt 270 180 90 degrees...

Страница 11: ...ll allow 1 fixture to act as the master and control all of the other slave fixtures You must set both the master and the slave s fixtures to the correct mode for this operation Master Settings 1 Connect the fixtures with DMX cables as shown in the Fixture Linking section 2 Use any one of the standalone modes for the master unit This includes NASL NAFA and NSTS Slave Settings 1 Press MENU until d 1...

Страница 12: ... This is accessed via the control panel Please see the instructions below for further explanation 1 Press MENU until one of the Operating Modes appears on the LED screen 2 Press ENTER 3 Using UP and DOWN select NAFA 4 Press ENTER to confirm settings 5 The mode will display as FASt after 5 seconds of inactivity Master Sound This fixture has a preprogrammed sound activated chase This is accessed via...

Страница 13: ...shown on the back panel drawing on the Product Overview section of this user manual Slave Fixture settings 1 Press MENU until d 1 appears on the LED screen 2 Using UP and DOWN set the DMX address to d 1 3 Press MENU until one of the Operating Modes appears on the screen 4 Using UP and DOWN set the mode to SLAv on the LED screen 5 Press ENTER Operation There are multiple functions that the CA 9 may...

Страница 14: ...fixture in a DMX or master slave operation you must daisy chain using DMX cables to link from one fixture to another In a master slave operation the DMX controller is not connected Additional signal link out DMX controller only in DMX operation Fixture 1 Fixture 2 Fixture 3 Back Panel ...

Страница 15: ...tment Please see the instructions below for location of this adjustment on the fixture as well as details on its use 1 Locate the manual focus adjustment using the drawings below 2 The control must first be pressed and then moved in one direction of the other using the bare hand Tools must not be used for this adjustment ...

Страница 16: ... 231 232 Ù 255 Color Macro No function RGBW full Red Green Blue White Cyan Magenta Yellow Yellow Green Light Blue Midnight Blue Purple Light Purple Pink Light Red Orange Color Chase adjust the speed with CH 12 12 000 Ù 255 Color Speed Fast slow 13 Auto Program 000 Ù 007 008 Ù 022 023 Ù 037 038 Ù 052 053 Ù 067 068 Ù 082 083 Ù 097 098 Ù 112 113 Ù 135 No function Auto Program 1 Auto Program 2 Auto Pr...

Страница 17: ... 063 064 Ù 077 078 Ù 091 092 Ù 105 106 Ù 119 120 Ù 133 134 Ù 147 148 Ù 161 162 Ù 175 176 Ù 189 190 Ù 203 204 Ù 217 218 Ù 231 232 Ù 255 Color Macro No function RGBW full Red Green Blue White Cyan Magenta Yellow Yellow Green Light Blue Midnight Blue Purple Light Purple Pink Light Red Orange Color Chase 6 Gobo 128 191 192 255 CW Gobo wheel rotate slow fast CCW Gobo wheel rotate slow fast Channel 4 wi...

Страница 18: ...e with three pin XLR male to female connectors The shield connection is pin 1 while pin 2 is Data Negative S and pin 3 is Data positive S General Maintenance To maintain optimum performance and minimize wear fixtures should be cleaned frequently Usage and environment are contributing factors in determining frequency As a general rule fixtures should be cleaned at least twice a month Dust build up ...

Страница 19: ...your fixture may perform erratically Test cables with an ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other Fixture Linking You will need a serial data link to run light shows of one or more fixtures using a DMX controller or to run synchronized shows on two or more fixtures set to a master slave operating mode The combined number...

Страница 20: ... CHART Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 Data signal Pin 2 Pin 2 Data signal Pin 3 Pin 3 Not used Pin 4 Not used Pin 5 Setting up a DMX Serial Data Link 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the controller 2 Connect the end of the cable coming from the controller which will have a female 3 pin connect...

Страница 21: ... wiring internal and or external Device does not power up No power Check for power on power outlet Loose power cord Check power cord Fixture is not responding to DMX Wrong DMX addressing Check Control Panel and unit addressing Damaged DMX cables Check DMX cables Wrong polarity settings on the controller Check polarity switch settings on the controller Loose DMX cables Check cable connections Fault...

Страница 22: ... UPS packing or double boxing is always a safe method to use CHAUVET reserves the right to use its own discretion to repair or replace product s If you are given an RMA please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 The RMA 5 A brief description of the symptoms Claims Damage incurred in shipping is the responsibility of ...

Страница 23: ...115 230 VAC 50 60 Hz Power consumption 120 VAC 60 Hz 66 W 0 6 A max 1 A inrush Power consumption 230 VAC 50 Hz 61 W 0 3 A max 0 8 A inrush Fuse F 1 A 250 V LIGHT SOURCE LED 1 13 W 900 mA x4 50 000 hrs PHOTO OPTIC Luminance 1 m 1 540 lux Beam Angle 13 THERMAL Maximum ambient temperature 104 F 40 C ORDERING INFORMATION MiNSpot RGBW MINSPOTRGBW WARRANTY INFORMATION Warranty 2 year limited warranty ...

Отзывы: