Safety Instructions 

Please read these instructions carefully, which include important information about 
the installation, usage and maintenance of this product. 

 

Please keep this User Guide for future consultation. If you sell the unit to another user, be sure 
that they also receive this instruction booklet. 

 

This product is for indoor use only! To prevent risk of fire or shock, do not expose fixture to rain 
or moisture. 

 

Make sure there are no flammable materials close to the unit while operating. 

 

Secure fixture to fastening device using a safety chain. 

 

Maximum ambient temperature (Ta) is 104°F (40°C). Do not operate the fixture at temperatures 
higher than this.  

 

In the event of a serious operating problem, stop using the unit immediately. Never try to repair 
the fixture by yourself. Repairs carried out by unskilled people can lead to damage or 
malfunction. Please contact the nearest authorized technical assistance center. 

 

Make sure the power cord is not crimped or damaged. 

 

Never disconnect the power cord by pulling or tugging on the cord. 

 

Avoid direct eye exposure to the light source while it is on.  

 

Do not daisy chain power to more than 37 units @ 120V. 

 
 

There are no user serviceable parts inside the unit. Do not open the housing or 
attempt any repairs. In the unlikely event that your unit may require service, please 
contact CHAUVET at 954-929-1115. 

 

 
 
 
 

2.

 

I

NTRODUCTION

 

Features 

 

6-channel DMX-512 LED beam effect 

 

Individual control of red, green, blue and white LEDs within each cluster (4 total) 

 

Adjustable strobe speed 

 

Built-in automated programs via DMX 

 

Built-in sound activated programs via master/slave or DMX 

 

Additional Features 

 

Razor-sharp rotating beams  

 

Additional power output: max 37 units @ 120V

 

 

Содержание Mega Moon

Страница 1: ...User Manual Snapshot Use on Dimmer Outdoor Use Sound Activated DMX 512 Master Slave Autoswitching Power Supply Replaceable Fuse User Serviceable Duty Cycle ...

Страница 2: ...nal Features 4 DMX CHANNEL SUMMARY 5 PRODUCT OVERVIEW 5 3 SETUP 6 FUSE REPLACEMENT 6 FIXTURE LINKING 6 DMX Data Cable 6 Cable Connectors 7 3 Pin to 5 Pin Conversion Chart 7 Setting up a DMX Serial Data Link 7 MASTER SLAVE FIXTURE LINKING 8 MOUNTING 8 Orientation 8 Rigging 8 4 OPERATING INSTRUCTIONS 9 OPERATION MODES 9 Stand Alone Mode Sound Active Auto Mode 9 Master Slave Mode Master Sound Master ...

Страница 3: ...information Failure to comply with this information may prevent the fixture from functioning correctly This paragraph reminds you of useful although not critical information AC Power This fixture has an auto switching power supply that can accommodate a wide range of input voltages 100V 240VAC 50 60Hz Before powering on the unit make sure the line voltage to which you are connecting it is within t...

Страница 4: ...ediately Never try to repair the fixture by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Make sure the power cord is not crimped or damaged Never disconnect the power cord by pulling or tugging on the cord Avoid direct eye exposure to the light source while it is on Do not daisy chain power to m...

Страница 5: ...mmary CHANNEL FUNCTION 1 Module 1 2 Module 2 3 Module 3 4 Module 4 5 Strobe 6 Function Product Overview DIP switches Fuse holder Power in Bracket adjustment knob 1 of 2 DMX in Safety eyebolt DMX out Hanging bracket Power out Microphone sensitivity Microphone ...

Страница 6: ...32 devices should be connected on one data link Connecting more than 32 fixtures on one serial data link without the use of an optically isolated DMX splitter may result in deterioration of the digital DMX signal Maximum recommended serial data link distance 500 m 1640 ft Maximum recommended number of fixtures on a serial data link 32 DMX Data Cable To link two or more fixtures together you must u...

Страница 7: ...roper cable conversion 3 PIN TO 5 PIN CONVERSION CHART Conductor 3 Pin Female output 5 Pin Male Input Ground Shield Pin 1 Pin 1 Data signal Pin 2 Pin 2 Data signal Pin 3 Pin 3 Do not use Pin 4 Do not use Pin 5 Setting up a DMX Serial Data Link 1 Connect the male 3 pin connector of the DMX cable to the output female 3 pin connector of the controller 2 Connect the other end of the cable to the male ...

Страница 8: ...in this manual for complete instructions for this type of configuration Mounting Orientation This fixture may be mounted in any safe position Rigging It is important never to obstruct the vents pathway Mount the fixture using a suitable C or O type clamp Adjust the angle of the fixture by loosening both knobs and tilting the fixture After finding the desired position retighten both knobs When sele...

Страница 9: ...ecreases the sensitivity turning the knob clockwise increases the sensitivity Note To use the fixture in automatic without the sound trigger you must use a DMX controller Master Slave Mode Sound This mode will allow you to link up to 32 fixtures together without a controller 1 Use standard DMX cables to daisy chain your fixtures together via the DMX connector on the rear of the fixtures For longer...

Страница 10: ...te Group 3 of White Group 1 of Red Group 2 of Red Group 3 of Red Group 1 of Green Group 2 of Green Group 3 of Green Group 1 of Blue Group 2 of Blue Group 3 of Blue All White All Red All Green All Blue All Red Green All Red Blue All Green Blue All Red Green Blue All Red White All Green White All Blue White Group 1 of Blue all White Group 2 of Blue all Red Group 3 of Blue all Green Group 1 of Blue g...

Страница 11: ...ettings for correct addressing Check DMX cables Check polarity switch settings Fixture is on but there is no movement to the audio Make sure you have the correct audio mode on the control switches If audio provided via jack make sure a live audio signal exists Adjust sound sensitivity knob Light will not come on after power failure Some discharge lamps require a cooling off period before the elect...

Страница 12: ... controller There are many different types of DMX controllable fixtures and they all may vary in the total number of channels required Choosing a start address should be planned in advance Channels should never overlap If they do this will result in erratic operation of the fixtures whose starting address are set incorrectly However you can control multiple fixtures of the same type using the same...

Страница 13: ...eaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RMA Products returned without an RMA will be refused Call C...

Страница 14: ... 1 A max 230 V Inrush Current 0 1 A 230 V Power Output 37 units max 120 VAC 74 units max 230 V LIGHT SOURCE LED 228 48 Red 72 Green 72 Blue 36 White 100 000 hrs COVERAGE Coverage angle horizontal spread 74 THERMAL Maximum ambient temperature 104 F 40 C CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 ...

Отзывы: