ST-3000LED User Manual
7
2009-12-10
/
14:04
Hanging Clamp
Flush Mounting Bracket
3. Setup
AC
P
OWER
Warning!
Verify that the power requirement label on your unit matches the line voltage
applied. All fixtures must be connected to circuits with a suitable Earth Ground.
To determine the power requirements for a particular fixture, see the label affixed to the back plate
of the fixture or refer to the fixture’s specifications chart.
A fixture’s listed current rating is its average current draw under normal conditions.
All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat
(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0%
to 100% switch.
Before applying power to a fixture, check th
at the source voltage matches the fixture’s
requirement.
All fixtures must be connected to circuits with a suitable Earth Ground.
P o w e r C a b l e C o n f i g u r a t i o n
C
ABLE
Pin
International
Screw Color
B
ROWN
Live
L
Yellow or Brass
B
LUE
Neutral
N
Silver
Y
ELLOW
/G
REEN
Earth
EG (Ground)
Green
M
OUNTING
O r i e n t a t i o n
This fixture can be mounted on a truss using a clamp in any position or against a flat surface using
the brackets provided.
R i g g i n g
The fixture includes a mounting yoke to which 1 rigging clamp can be bolted
and (2) Flush Mount Brackets for flush mounting to flat surfaces. You must
supply your own clamp and make sure the clamp is capable of supporting the
weight of this fixture. You can order C-clamps from any CHAUVET dealer or
distributor.
1.
Block access below the work area and use suitable and stable
platform when installing or servicing fixture.
2.
Align the clamp screw with the center hole on the yoke and
tighten.
3.
Verify the structure can hold 10 times the weight of all to-be
installed fixtures.
4.
Adjust the angle on the yoke arm as necessary.
5.
Always use a safety cable or chain as a secondary source of
attachment. The safety cable must hold 10 times the weight of the
fixture. If safety cable attachment point is provided that is
permanently affixed to the surface or body of the fixture, use that
instead of looping through a hanging yoke/arm.
F l u s h M o u n t i n g
1.
Draw a screw hole template on a large piece of vellum or transparent paper for best alignment.
2.
Place paper against the mounting surface and drill holes or mark the surface for drilling.
3.
Hang Panel.