background image

 

 

 

 

 

ST-3000LED User Manual 

 

2009-12-10

/

14:04 

Hanging Clamp 

Flush Mounting Bracket 

3. Setup 

AC

 

P

OWER

 

Warning! 

Verify that the power requirement label on your unit matches the line voltage 
applied. All fixtures must be connected to circuits with a suitable Earth Ground. 

  To determine the power requirements for a particular fixture, see the label affixed to the back plate 

of the fixture or refer to the fixture’s specifications chart.  

 

A fixture’s listed current rating is its average current draw under normal conditions.  

  All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat 

(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% 
to 100% switch.  

  Before applying power to a fixture, check th

at the source voltage matches the fixture’s 

requirement.  

  All fixtures must be connected to circuits with a suitable Earth Ground.

P o w e r   C a b l e   C o n f i g u r a t i o n  

C

ABLE

 

Pin

 

International

 

Screw Color

 

B

ROWN

 

Live 

Yellow or Brass 

B

LUE

 

Neutral 

Silver 

Y

ELLOW

/G

REEN

 

Earth 

EG (Ground)  

Green 

M

OUNTING

 

O r i e n t a t i o n  

This fixture can be mounted on a truss using a clamp in any position or against a flat surface using 

the brackets provided. 

R i g g i n g  

The fixture includes a mounting yoke to which 1 rigging clamp can be bolted 
and (2) Flush Mount Brackets for flush mounting to flat surfaces. You must 
supply your own clamp and make sure the clamp is capable of supporting the 
weight of this fixture. You can order C-clamps from any CHAUVET dealer or 
distributor. 

1. 

Block access below the work area and use suitable and stable 
platform when installing or servicing fixture. 

2. 

Align the clamp screw with the center hole on the yoke and 
tighten. 

3. 

Verify the structure can hold 10 times the weight of all to-be 
installed fixtures. 

4. 

Adjust the angle on the yoke arm as necessary. 

5. 

Always use a safety cable or chain as a secondary source of 
attachment. The safety cable must hold 10 times the weight of the 
fixture. If safety cable attachment point is provided that is 
permanently affixed to the surface or body of the fixture, use that 
instead of looping through a hanging yoke/arm. 

F l u s h   M o u n t i n g  

1. 

Draw a screw hole template on a large piece of vellum or transparent paper for best alignment.  

2. 

Place paper against the mounting surface and drill holes or mark the surface for drilling.  

3. 

Hang Panel. 

Содержание LED Techno Strobe ST-3000LED

Страница 1: ...CHAUVET 3000 N 29 th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2009 12 10 14 04 LED Techno Strobe ST 3000LED User Manual ...

Страница 2: ... 6 3 SETUP 7 AC POWER 7 MOUNTING 7 FIXTURE LINKING 8 Data Cabling 8 DMX Data Cable 8 Cable Connectors 8 3 Pin to 5 Pin Conversion Chart 9 SETTING UP A DMX SERIAL DATA LINK 9 STANDALONE MASTER SLAVE FIXTURE LINKING 9 4 OPERATING INSTRUCTIONS 10 STANDALONE MODE 10 Single Fixture Mode 10 Master Slave Mode 10 Setup 10 Dipswitch Options 10 DMX CONTROL MODE 11 Configuring for DMX control 11 Setting the ...

Страница 3: ...y it is important that the fixture be returned in the original factory box and packing Note If you should require sending any items back to CHAUVET call CHAUVET for a RMA Return Merchandise Authorization number The factory will not allow any shipments without an RMA Your shipment includes the following 1 x LED Techno Strobe 1 x Power cable 1 x Warranty Card 1 x Users Manual CONTACT US World Wide G...

Страница 4: ...n Using the wrong type of lamp in this product VOIDS the warranty Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture The unit must be installed in a location with adequate ventilation at least 50cm from adjacent surfaces Be sure that no ventilation slots are blocked Main...

Страница 5: ...ues in Channel 1 2 Introduction FEATURES 3 channel DMX 512 LED white strobe light Blackout static dimmer strobe Adjustable flash rate dimmer and static in stand alone via DIP switches Built in automated programs via master slave or DMX Built in sound activated programs via master slave or DMX ADDITIONAL FEATURES Linkable with LED Shadow LED Shadow 2 LED Techno Strobe LED Techno Strobe RGB LEDsplas...

Страница 6: ...04 DMX Input DIP switches DMX Addressing IEC Plug for AC Input Fuse Compartment DMX Output LED Front Panel Hanging Yoke Audio Sensitivity Rotary knob Red LED Power Indicator Blue LED Signal Indicator Power Link Out Flush Mounting Bracket PRODUCT OVERVIEW ...

Страница 7: ...s fixture can be mounted on a truss using a clamp in any position or against a flat surface using the brackets provided Rigging The fixture includes a mounting yoke to which 1 rigging clamp can be bolted and 2 Flush Mount Brackets for flush mounting to flat surfaces You must supply your own clamp and make sure the clamp is capable of supporting the weight of this fixture You can order C clamps fro...

Страница 8: ...f you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DMX Data Cable Use a Belden 9841 or equivalent cable which meets the specifications for EIA RS 485 applications Standard microphone cables cannot transmit DMX data reliably over long distances The cable will have the following characteristics 2 ...

Страница 9: ...male output 5 Pin Male Input Ground Shield Pin 1 Pin 1 Data signal Pin 2 Pin 2 Data signal Pin 3 Pin 3 Not Used Pin 4 Not Used Pin 5 SETTING UP A DMX SERIAL DATA LINK 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the controller 2 Connect the end of the cable coming from the controller which will have a female 3 pin connector to the input connector...

Страница 10: ...slave mode setup consists of more than one fixture connected in a serial data link without the use of a controller In a master slave operation the slave fixtures will synchronize and will behave either identically or in a planned chase pattern to the master unit which must be the first in the serial daisy chain A Master Slave ST 3000LED system can consist of an unlimited range of fixtures or at le...

Страница 11: ...setting the DMX address read the section titled Setting the DMX address in this Chapter Setting the DMX address Each fixture requires a start address from 1 to 511 A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address For example a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100 would...

Страница 12: ... be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RA Products returned without an RA will be refused Call CHAUVET and request RA prior to shipping the fixture Be prepared to provide the model number serial number and a brief description of the cause for the return Be sure to properly pack fixture...

Страница 13: ...the internal optics at least every 30 60 days BINARY DMX DIP SWITCH ADDRESSING Each DIP switch has an associated value Adding the value of each switch in the ON position will provide the final address Determining which switches to toggle ON given a specific desired address or value can be accomplished in the following manner By subtracting the largest switch value possible from the selected start ...

Страница 14: ...36 268 300 332 364 396 428 460 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 ...

Страница 15: ... of channel 1 For example while Channel 1 is set between 000 and 029 the following conditions will apply Channel 2 will control Strobing from 0 to 100 Channel 3 will control Dimming Intensity from 100 to 0 Channel Value Function Ch 2 Ch 3 1 000 039 Dimmer Strobe Mode Strobe 0 255 Intensity 100 0 040 079 Program 1 Speed Slow Fast 080 119 Program 2 120 159 Program 3 160 199 Program 4 200 239 Program...

Страница 16: ... Quantity 192 Total white PHOTO OPTIC Beam Angle 21 x 24 Field Angle 40 x 43 Illuminance 1 321 lux 1 m Color Temperature 6 500K 8 000K CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 3 ORDERING INFORMATION LED Techno Strobe ST 3000LED TECHNICAL SUPPORT Addre...

Отзывы: