background image

 
Setup

 

-6- 

 

Vesuvio™ RGBA User Manual Rev. 1 

3.

 

S

ETUP

 

AC Power 

Each  Vesuvio™ RGBA  has a fixed power supply that works with an input voltage of  
120 VAC, 60 Hz. To determine the power requirements for each Vesuvio™ RGBA, refer to the 
label affixed to the product. You can also refer to the 

Technical Specifications

  chart in this 

manual. 
The listed current rating indicates the maximum current draw during normal operation. For more 
information, you may download Sizing Circuit Breakers from the CHAUVET® website 

www.chauvetlighting.com/download/pro

 

Always connect this product to a protected circuit with an appropriate electrical ground 
to avoid the risk of electrocution or fire. 

 

Never connect this product to a rheostat (variable resistor) or dimmer circuit, even if the 
rheostat or dimmer channel serves only as a 0 to 100% switch. 

AC Plug 

The Vesuvio™ RGBA comes with a power input cord terminated with a Neutrik® powerCON® A 
connector on one end and an Edison plug on the other end (U.S. market). If the power input 
cord that came with your product has no plug, or if you need to change the Edison plug, use the 
table below to wire the new plug to the power input cord. 

 

Connection 

Wire (U.S.) 

Wire (Europe) 

Screw Color 

AC Live 

Black 

Brown 

Yellow or Brass 

AC Neutral 

White 

Blue 

Silver 

AC Ground 

Green/Yellow 

Green/Yellow 

Green 

 

Resetting the 

Breaker 

This product is equipped with a resettable circuit breaker on the power input circuit.  
If the breaker trips, all sections of this product will lose power. Refer to the following instructions 
for resetting the breaker. 

 

This product is equipped with a resettable circuit breaker. If the breaker trips, all sections of this 
product will lose power. 
1.  Disconnect the product from power. 
2.  Allow the product to cool for 15 minutes. 
3.  After 15 minutes, try to reset the breaker by pressing the button until it latches in the 

operation position. 

4.  Connect the product to power and continue using as recommended. 

 

Disconnect this product from the power outlet before resetting the breaker. 
If the breaker does not reset (the breaker will not remain in  the ON position), contact 
CHAUVET® immediately. This indicates a possible internal malfunction. 

DMX Linking 

You can link the  Vesuvio™ RGBA  to a DMX controller using a 3-  or 5-pin DMX connection. If 
using other DMX compatible products with the Vesuvio™ RGBA, you can control each 
individually with a single DMX controller. 

DMX 

Personalities 

The  Vesuvio™ RGBA  uses a 3-  or 5-pin DMX data connection for its 9-channel DMX 
personality. 

 

Refer to the 

Introduction

 chapter for a brief description of each DMX personality.  

 

Refer to the 

Operation

 chapter to learn how to configure the Vesuvio™ RGBA to work in 

these personalities. 

 

The 

DMX Values

 section provides you with detailed information regarding the DMX 

personalities. 

 

If you are not familiar with or need more information about DMX standards or the DMX 
cables needed to link this product to a DMX controller, download the DMX Primer from 
the CHAUVET® website: 

www.chauvetlighting.com/download/pro

 
 
 

 

Содержание Green Thinking Professional Vesuvio RGBA

Страница 1: ...User Manual ...

Страница 2: ...only CHAUVET expressly prohibits the usage copy storage distribution modification or printing of this manual or its content for any other purpose without written consent from CHAUVET Document Printing For better results print this document in color on letter size paper 8 5 x 11 in double sided If using A4 paper 210 x 297 mm configure your printer to scale the content accordingly Intended Audience ...

Страница 3: ...ntions 1 Symbols 1 Safety Notes 2 Personal Safety 2 Mounting And Rigging 2 Power And Wiring 2 Operation 2 Expected LED Lifespan 2 2 Introduction 3 Description 3 Features 3 Overview 4 Dimensions 5 3 Setup 6 AC Power 6 AC Plug 6 Resetting the Breaker 6 DMX Linking 6 DMX Personalities 6 Mounting 7 Orientation 7 Rigging 7 Procedure 7 ...

Страница 4: ...ontrol Options 8 Programming 8 Preparing for Operation 8 Startup 8 Menu Map 9 DMX Values 9 Starting Address 10 Setting the LED Color 10 Timer Mode 10 Manual Mode 10 Timer Mode Parameters 10 5 Technical Information 11 Maintenance 11 Storage 11 6 Technical Specifications 12 Returns 13 Contact Us 13 ...

Страница 5: ...T within 7 days of delivery Manual Conventions Convention Meaning 1 512 A range of values in the text 50 60 A set of mutually exclusive values in the text SET A button on the product s control panel Settings A product function or a menu option MENU Settings A sequence of menu options 1 10 A range of menu values from which to choose in a menu Yes No A set of two mutually exclusive menu options in a...

Страница 6: ...s product to the proper voltage in accordance with the specifications in this manual or on the product s specification label Never connect this product to a dimmer pack or rheostat Make sure the power cord is not crimped or damaged Never disconnect this product by pulling or tugging on the power cable Operation Make sure there is adequate fog fluid in the machine to prevent pump and heater damage ...

Страница 7: ...eating 1 6 kW heater a 2 5 liter fluid tank and features a 40 000 cubic feet per minute cfm output Features Advanced red green blue and amber RGBA LED color mixing 40 000 cfm fog output for intense large effects 2 5 l fluid tank for reliability in production 1 6 kW fluid heater for voluminous heavy bursts of fog Strong sturdy construction for numerous production types DMX control for ease of use i...

Страница 8: ...4 Vesuvio RGBA User Manual Rev 1 Overview Power In DMX Out Control Panel Front View Rear View Side View Handle Safety Loop LED s Nozzle Fluid Tank Fluid Tank Hose DMX In DMX Out Power Switch Breaker DMX Out Top View ...

Страница 9: ...Introduction Vesuvio RGBA User Manual Rev 1 5 Dimensions 13 23 in 336 mm 9 09 in 231 mm 19 21 in 488 mm ...

Страница 10: ...er input circuit If the breaker trips all sections of this product will lose power Refer to the following instructions for resetting the breaker This product is equipped with a resettable circuit breaker If the breaker trips all sections of this product will lose power 1 Disconnect the product from power 2 Allow the product to cool for 15 minutes 3 After 15 minutes try to reset the breaker by pres...

Страница 11: ... an installation location consider easy access to this product for operation programming adjustments and routine maintenance Make sure to mount this product away from any flammable material as indicated in the Safety Notes Never mount in places where rain high humidity extreme temperature changes or restricted ventilation may affect the product Procedure The Vesuvio RGBA comes with rubber feet for...

Страница 12: ...teps 1 Withdraw the fluid tank from its compartment and remove its cap 2 Verify that the two plastic hoses attached to the cap are in place and in good condition 3 Pour CHAUVET HDF or QDF fog fluid into the tank and replace the cap 4 Return the tank back to its compartment in the Vesuvio RGBA 5 Make sure the plastic hose entering the Vesuvio RGBA from the fluid tank cap is not bent or kinked 6 Con...

Страница 13: ...nterval Set CHAUVET 1 200s Duration Set CHAUVET 1 10s Color CHAUVET 1 7 DMX512 Add CHAUVET 1 512 DMX Values 9CH Channel Function Value Percent Setting 1 Fog 000ó010 011ó255 No function Fog on 2 Dimmer 000ó255 0 100 3 Red 000ó255 0 100 4 Green 000ó255 0 100 5 Blue 000ó255 0 100 6 Amber 000ó255 0 100 7 Strobe 000ó255 0 100 8 Auto Color 000ó010 011ó255 No function Color mixing 9 Auto Speed 000ó255 0 ...

Страница 14: ... 1 Press TIMER and the display will show a countdown of the interval timer 2 When the counter reaches zero 0 the Vesuvio RGBA will start producing haze and light 3 The haze and light output duration during Timer mode is set by the Duration Set menu option 4 The color of the LEDs is set using the Color menu option 5 This cycle will repeat itself until you press TIMER again or until the Vesuvio RGBA...

Страница 15: ...e a vacuum or dry compressed air and a soft brush to remove dust collected on the external vents 8 Clean all external surfaces with a mild solution of non ammonia glass cleaner or isopropyl alcohol 9 Apply the solution directly to a soft lint free cotton cloth or a lens cleaning tissue 10 Wipe any dirt or grime to the outside edges of the lens surface 11 Gently polish the lens surfaces until they ...

Страница 16: ... Power input connector Neutrik powerCON A Neutrik powerCON A Power cord plug Edison U S Local plug Light Source Type Power Lifespan LED 2 W 50 000 hours Color Quantity Current Red 7 650 mA Green 7 650 mA Blue 7 650 mA Amber 7 650 mA Photo Optic Parameter Standard Optics Illuminance 5 m 720 lux Operation Capacity Consumption Heat up Time Tank Capacity Fluid Consumption 7 min 0 7 gal 2 5 l 150 ml mi...

Страница 17: ...dEx packing or double boxing is recommended CHAUVET reserves the right to use its own discretion to repair or replace returned product s CONTACT US WORLD HEADQUARTERS CHAUVET General Information Address 5200 NW 108 th Avenue Sunrise FL 33351 Voice 954 577 4455 Fax 954 929 5560 Toll free 800 762 1084 Technical Support Voice 954 577 4455 Press 4 Fax 954 756 8015 Email tech chauvetlighting com World ...

Отзывы: