background image

 
 
 
 

Page 8 of 15 

Geyser™ RGB Jr. User Manual Rev. 2 

 

Mounting

 

Before mounting the  product, read and follow the safety recommendations indicated in 
the 

Safety Notes

.

 

 

 

Orientation 

Primarily, the  Geyser™  RGB Jr.  is  to be floor  mounted in  a  vertical  fog jet  orientation. 
Alternatively, it may also be mounted in a floor mounting/horizontal fog jet orientation or 
in an overhead mounting/downward fog jet  orientation;  however, be sure to  follow 
instructions closely to avoid tank spills with alternate mountings. 

 

When mounting the Geyser™ RGB Jr.  in any  inverted position, remove the fluid 
tank from the holder and set it upright on an adjacent surface.

 

 

 

Rigging 

 

Before deciding on a location, always make sure there is easy access to the product 
for maintenance and fluid replenishment. 

 

Make sure that the structure or surface onto which you are mounting the product 
can support the product’s weight (see the 

Technical Specifications

). 

 

When mounting the product overhead, always use a safety cable. Mount the 
product securely to a rigging point, such as an elevated platform or a truss. 

 

When rigging the product onto a truss, you should use mounting clamps of 
appropriate weight capacity. Two threaded mounting holes (size M12) are on the 
bottom of the product, which are appropriate for this purpose. 

 

The rubber feet also serve as floor supports. When mounting the product on the 
floor, make sure that the product and cables are away from people and vehicles. 

 

 

Floor Mounting 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fluid Tank 

Position 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

To avoid spillage with any mounting, always position the fluid tank with the tank’s 
cap in the uppermost position above the tank’s fluid line.

 

 

 

Floor Mounting – Vertical Fog Jet 

Floor Mounting  

Horizontal Fog Jet 

Overhead Mounting – Downward Fog Jet 

Vertical Fog Jet 

Horizontal Fog Jet 

Fluid Line

 

Содержание Geyser RGB Jr

Страница 1: ...User Manual ...

Страница 2: ... 4 2 Introduction 5 Overview 5 Dimensions 6 3 Setup 7 AC Power 7 Fuse Replacement 7 Mounting 8 Orientation 8 Rigging 8 Tank Inversion for Inverted Mounting 10 4 Operation 11 Control Panel Operation 11 Menu Map 11 Configuration Standalone 12 Wireless Remote Control 12 Programmable Color Selection 12 5 Technical Information 13 Fogger Maintenance 13 Storage 13 6 Technical Specifications 14 Returns 15...

Страница 3: ...ues 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified Menu Settings A sequence of menu options to be followed ENTER A key to be pressed on the product s control panel ON A value to be entered or selected Symbols Symbol Meaning Critical installation configuration or operation information Not following these instructions may make the product not work cau...

Страница 4: ...r local emergency service 911 in the US for help Do not add perfume alcohol gasoline or any other flammables to the fog fluid Always make sure that the voltage of the outlet to which you are connecting the product is within the range stated on the decal or panel of the product The product is for indoor use only IP20 To prevent risk of fire or shock do not expose the product to rain or moisture Alw...

Страница 5: ...User Manual Rev 2 Page 5 of 15 2 INTRODUCTION Overview LED Display Control Buttons Nozzle and LEDs Fluid Tank On Off Switch Safety Eye Loop Remote Control Receiver Port Fuse Holder Power In Handles Manual Fog Button ...

Страница 6: ...Page 6 of 15 Geyser RGB Jr User Manual Rev 2 Dimensions 7 55 in 191 9 mm 10 39 in 264 mm 16 04 in 407 5 mm 2 39 in 60 8 mm ...

Страница 7: ... appropriate electrical ground to avoid the risk of electrocution or fire Never connect the product to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel serves only as a 0 100 switch Fuse Replacement Disconnect the product from power before replacing the fuse 1 Disconnect the product from power 2 Wedge the tip of a flat head screwdriver into the slot of the fuse...

Страница 8: ...hat the structure or surface onto which you are mounting the product can support the product s weight see the Technical Specifications When mounting the product overhead always use a safety cable Mount the product securely to a rigging point such as an elevated platform or a truss When rigging the product onto a truss you should use mounting clamps of appropriate weight capacity Two threaded mount...

Страница 9: ... tank when rigging in this manner The dimensions shown for the mounting hole positions are included here to aid in installation Safety Cable for the Fluid Tank Mounting Clamps for the Geyser RGB Jr works with CLP 15 or CLP 15N clamp from CHAUVET TRUSST or other elevated platform or truss The Fluid Tank in an upright position Safety Cable Overhead Mounting Downward Fog Jet 8 46 in 215 mm 6 49 in 16...

Страница 10: ...ounting 1 Remove the screws and the bottle lock to take out the tank 2 Turn the fog machine upside down and remove the screws to take off the removable plate 3 Attach the removable plate to the opposite side and secure the tank with the bottle lock Bottle Lock Removable Plate ...

Страница 11: ...ptions or selects a higher value DOWN Scrolls down the list of options or selects a lower value ENTER Activates a menu option or a selected value Menu Map Mode Programming Steps Description Color Program CH 1 CH 4 oFF Color program off default rAnd Selects preset color program Co 1 Co 9 Selects preset colors Fluid Sensor orL on Selects fluid sensor to on or off oFF The Geyser RGB Jr Wireless Remot...

Страница 12: ...old down the button If the color program is set to oFF for any trigger button only fog output is triggered when that button is pressed Programmable Color Selection To select either the preset color program or one preset color to illuminate the fog using the wireless remote control follow the instructions below 1 Press MENU repeatedly until CH 1 CH 4 shows on the display Select CH 1 CH 2 CH 3 or CH...

Страница 13: ...ed area until the tank is almost empty Do not allow the pump to run dry 6 Refill with fog fluid Run the machine briefly to clear any cleaning solution from the pump and heater Fog Cleaner Quart FCQ was specifically developed by CHAUVET to clean your Geyser RGB Jr Make sure you use FCQ regularly to increase the life of your fogger Storage Before storing the fogger run FCQ through the system as desc...

Страница 14: ...ing current 5 63 A 3 A Fuse F 7 A 250 V F 7 A 250 V Power I O US Worldwide UK Europe Power input connector IEC IEC Power output connector Edison IEC Power Cord plug Edison US Local plug Light Source Type Power Lifespan LED 3 W 50 000 hours Color Quantity Current Red 3 900 mA Green 3 900 mA Blue 3 900 mA Operation Capacity Consumption Heat up Time Tank Capacity Fluid Consumption 5 min 2 5 l 123 ml ...

Страница 15: ...ly write the following information on a piece of paper and place it inside the box Your name Your address Your phone number RMA number A brief description of the problem Be sure to pack the product properly Any shipping damage resulting from inadequate packaging will be your responsibility FedEx packing or double boxing are recommended CHAUVET reserves the right to use its own discretion to repair...

Отзывы: