background image

Technical Information 

 
 

April 7, 2010 

-23- 

Followspot 1200 User Manual Rev. 03e 

Parts List 

 

No 

Part code 

Description 

 

No 

Part code 

Description 

P100-FS12RC 

Rear cover 

 

55 

P100-FS12LPFO 

Left plate for optic 

P100-FS12BA 

Bar A 

 

56 

P100-FS12SWA 

Steel wire A 

P100-FSXLRF 

XLR Female Socket 

 

57 

P100-FS12REF 

Reflector 

P100-FSXLRM 

XLR male Socket 

 

58 

P100-FS12BPFO 

Back plate for optic 

P100-FSFUSEHOL  Fuse holder 

 

59 

P100-FS12MPFO 

Mid plate for optic 

P100-FS12ONOF 

On/off Switch 

 

60 

P100-FS12LENA 

Lens A 

P100-FS12DCO 

Display Cover 

 

61 

P100-FS12SFL 

Sleeve for Lens 

P130-FS12FAN1 

DC Fan 

 

62 

P100-FS12LNC 

Lens clip 

P100-FS12FSC 

Fan Screen 

 

63 

P100-FS12BFUC 

Upper cover bracket  

10 

P100-FS12LSC 

Left Side Cover 

 

64 

P100-FS12LSS 

Lens sleeve 

11 

P100-FS12FIL 

Filter (15 A) 

 

65 

P100-FS12LENB 

Lens B 

12 

P100-FS12ACP 

AC Capacitor 

 

66 

P100-FS12COVR 

Cover 

13 

P100-FS12FJP 

Fan Joint Plate 

 

67 

P100-FS12FPFO 

Front Plate for optic 

14 

P100-FS12LCP 

Lamp Control Plate 

 

68 

P100-FS12RPFO 

Right plate for optic 

15 

P140-FS12BALL 

Ballast (1200 W) 

 

69 

P130-FS12FAN2 

DC fan 

16 

P100-FS12IGN 

Igniter (5-7 KV) 

 

70 

P100-FS12CFTS 

Thermal switch clip 

17 

P100-FS12BRKT 

Bracket 

 

71 

P100-FS12THER 

Thermal switch 

18 

P100-FS12MTS 

Multi-Tap Socket 

 

72 

P100-FS12BBRKT  Base Bracket 

19 

P140-FS12ELTR 

Transformer 

 

73 

P100-FS12PPST 

Plastic post 

20 

P170-FS12NOIS 

Noise filter PCB 

 

74 

P100-FS12LPBKT  Lamp bracket 

21 

P100-FS12DIFF 

Diffuser 

 

75 

P100-FS12LSSA 

Lamp shelves A 

22 

P100-FS12BAFF 

Baffle 

 

76 

P100-FS12LSSB 

Lamp shelves B 

23 

P100-FS12ISC 

Iris steel cable 

 

77 

P100-FS12LSC 

Left side cover 

24 

P100-FS12BFAI 

Bar for adjusting Iris 

 

78 

P100-FS12PLHN 

Plastic handle 

25 

P100-FS12MP1 

Motor Plate 1 

 

79 

P100-FS12DCP 

Die cast part 

26 

P100-FS12POST 

Post 

 

80 

P100-FS12PFM 

10 mm post  

27 

P100-FS12GAS 

Gasket 

 

81 

P170-FS12ISCW 

ISC-1200D PCB 

28 

P100-FS12TCFH 

Top cover 

 

82 

P100-FS12DCPB 

Bracket die cast part 

29 

P100-FS12MP2 

Motor plate 2 

 

83 

P100-FS12HAND 

Handle 

30 

P100-FS12BER 

Bearing 

 

84 

P100-FS12LOOP 

Loop 

31 

P100-FS12BELT 

Belt 

 

85 

P100-FS12PFM1 

10 mm post  

32 

P100-FS12TCJ 

Top covers’ jointer 

 

86 

P100-FS12FFCW 

Flange for color wheel 

33 

P100-FS12PLS 

Plastic slider 

 

87 

P100-FS12TBRKT  Bottom bracket 

34 

P100-FS12BEW 

Bearing wheel 

 

88 

P100-FS12XNUT 

Bracket hex nut 

35 

P100-FS12LNHOL  Lens holder 

 

89 

P100-FS12BGAS 

Bracket gasket 

36 

P100-FS1288MB 

88 mm Bar 

 

90 

P100-FS12BNIP 

Bracket  

37 

P100-FS12TPCR 

Top cover 

 

91 

P100-FS12PCF 

Plastic flange 

38 

P100-FS12WNP 

Warning Plate 

 

92 

P100-FS12P5M 

56.5 mm Post 

39 

P100-FS12NUT 

Nut 

 

93 

P100-FS12COW2  Color wheel 

40 

P100-FS12550DL 

550º Lens 

 

94 

P100-FS12UBRKT  Upper bracket 

41 

P100-FS12FOCF 

Focus Frame 

 

95 

P100-FS12BTCO 

Bottom cover 

42 

P100-FS12CMP 

Color Motor plate 

 

96 

P100-FS12CTB 

Controller base 

43 

P100-FS12COW1  Temperature wheel 

 

97 

P100-FS12BDB 

Body baffle 

44 

P100-FS12BARB 

Bar B 

 

98 

P170-FS12DRV 

Control board 

45 

P100-FS12CFL 

Color Flange 

 

99 

P100-FS123TS 

3-tap switch 

46 

P100-FS1298MP 

98.5 mm Post 

 

100 

P100-FS122TS 

2-tap switch 

47 

P100-FS12PFCW 

Plate for color wheel motor 

 

101 

P100-FS12CTC 

Controller cover 

48 

P100-FS12SWT 

15 A switch 

 

102 

P100-FS12LGAS 

Leather washer 

49 

P100-FS12SHUT 

Shutter 

 

103 

P100-FS12ANUT 

Allen nut 

50 

P100-FS12FFSC 

Flange for shutter/color wheel 

 

104 

P100-FS12CHAN 

Controller handle 

51 

P100-FS12PTMT 

20 mm Post  

 

105 

P170-FS12MAS 

Master board 

52 

P110-FS12MOT 

1.8º step motor 

 

106 

P100-FS12BRCN 

Bracket for controller 

53 

P100-FS12PLT 

Plate 

 

107 

P100-FS12GLAS 

Glass 

54 

P100-FS12HEX 

Hex 

 

108 

P100-FS12HOOK 

Safety hook 

 

 

Содержание Followspot 1200

Страница 1: ...User Manual ...

Страница 2: ...4 paper 210 x 297 mm configure your printer to scale the content of this document to A4 paper Intended Audience Any person in charge of installing operating and or maintaining the Followspot 1200 should read the Quick Start Guide that shipped with the Followspot 1200 unit and this manual in their entirety before installing operating or maintaining the Followspot 1200 Disclaimer CHAUVET believes th...

Страница 3: ...Voltage Frequency Selection 7 Lamp 8 Lamp Removal 8 Lamp Installation 9 DMX Linking 10 DMX Connection 10 Mounting 11 Orientation 11 Rigging 11 4 Operation 12 Control Panel Description 12 Programming Panel 12 Navigation Functions 12 Followspot 1200 Menu Options 13 Normal Mode 13 Offset Mode 13 Programming Procedure 14 Normal Mode 14 Normal Mode Cont 15 Offset Mode 15 External Console 17 Controls 17...

Страница 4: ...mber of Fixtures 27 DMX Data Cabling 27 Making your Own DMX Cable 27 DMX Cable Characteristics 27 DMX Cable Connectors 28 3 Pin to 5 Pin Conversion Chart 28 DMX Connection 28 Master Slave Linking 29 Master Slave Connection 29 ID Addressing 30 Single Row Connection 30 Standard Block Connection 30 Repeated Row Block Connection 30 Other Effects 30 Sizing the Circuit Breakers 31 Using the Spec Sticker...

Страница 5: ...nvention Meaning 1 512 A range of values 50 60 A set of mutually exclusive values in the text 10 A DIP switch to be configured Claims A fixture function a new term a section or a chapter COLORado UM The name of another publication or manual SET A key to be pressed on the fixture s control panel Settings A menu option that can be selected but not modified MENU Settings A sequence of menu options to...

Страница 6: ...0 is on Lamp explosion hazard Do not open the lamp cover within five minutes of having turned off the fixture The bulb remains hot for a long time after turn off Never touch the bulb barehanded and always hand it by its metallic contacts Always disconnect the Followspot 1200 from its power source before servicing Do not touch the Followspot 1200 s housing when operating because it may reach up to ...

Страница 7: ...al console The Followspot 1200 features a bright 4 digit display and four buttons to perform all its programming functions The external console features four sliders and several buttons to control the fixture in a stand alone fashion However the user can connect the Followspot 1200 to a DMX daisy chain data link to control it from a standard DMX controller along with other DMX compatible fixtures ...

Страница 8: ...the Control Panel refer to the Fuse Replacement and DMX Linking sections in the Setup chapter as well as the Operation chapter For details about the external console refer to the External Console section of the Operation chapter Housing Fans Yoke Tripod Safety loop Knob Control Panel External Console ...

Страница 9: ...Introduction April 7 2010 5 Followspot 1200 User Manual Rev 03e Product Dimensions ...

Страница 10: ...ers the control panel through a strain relief boot This side of the power cord is hard wired to the fixture Therefore there is no removable power connector on the control panel The outlet side of the power cord is bare ended This way the users will be able to equip it with the power plug that best matches the local standards and regulations Power Cord Pin Out Connection Wire US Wire Europe IP 66 P...

Страница 11: ... 1 Unfasten the thumbscrew T and slide the front cover FC slightly forward 2 Unscrew the two Allen screws A and remove the bracket B 3 Carefully pick up and slide the back cover BC backward making sure not to pull the wires that run from its fans to the Fan Control PCB inside the housing Cover Removal Diagram Two black wires arrive to the terminal strip TS One wire labeled 1 and the other labeled ...

Страница 12: ...n the lamp cover Opening the Fixture 1 Unfasten the thumbscrew T and slide the front cover FC slightly forward 2 Loosen the thumbscrew that hold the lamp cover LC and lift it to expose the lamp socket Lamp Removal Diagram Always wear safety goggles and soft gloves when handling the lamp The bulb remains hot for a long time after turn off Never touch the bulb barehanded and always hand it by its me...

Страница 13: ...ed on page 8 2 Before installing the lamp loosen its end screws 3 Hold the lamp by its metallic contacts and slide it into the slots 4 Ensure that the flat washers on the lamp shafts are on the thumbscrew side of the slot to ensure maximum contact 5 Evenly push the clips backward to allow the lamp to go all the way into the slots 6 Rotate the lamp until the nipple is on the top of the bulb 7 Tight...

Страница 14: ...a brief description of this mode and the Operation chapter to learn how to configure the Followspot 1200 to work in this mode The diagram below shows the Followspot 1200 DMX connectors DMX Connectors Diagram Pins 4 and 5 of the External Console Only socket carry power for the external console Therefore DO NOT connect the DMX cable to this socket Otherwise you could damage the DMX controller or the...

Страница 15: ... platform When selecting an installation location consider ease of access to the fixture for operation programming adjustments and routine maintenance Never mount the fixture in places where rain high humidity extreme temperature changes or restricted ventilation may affect it Make sure that the location where you are mounting the fixture can support its weight 84 lbs 38 kg as well as the operator...

Страница 16: ...ure s parameters as described in the Menu Map and the programming procedures Display The Followspot 1200 s display has four 7 segment blue LED modules Function Change To select a function press MENU repeatedly until the desired function shows on the display Alternatively if the display shows a function name you could press UP or DOWN to look for another function Function Selection To select a func...

Страница 17: ...the built in self test program Fixture Hours N A Shows the amount of hours the fixture has been on Lamp On Off On Off Turns the lamp on or off Reset N A Resets the fixture to its factory default settings Offset Mode Function 1 st Level 2 nd Level Description Color Offset 127 127 Performs the fine position adjustment for the color wheel Effect Offset 127 127 Performs the fine position adjustment fo...

Страница 18: ...new value press ENTER The display will show the next function name Color Wheel Blackout Enables disables the blackout fixture while changing colors 1 Press MENU repeatedly until the display shows 2 Press ENTER to show the current setting Yes No The display will start blinking 3 To exit without changing the value press MENU 4 To change the setting press UP or DOWN 5 To save the new value press ENTE...

Страница 19: ...ult settings The reset function does not affect the Fixture Hours total Offset Mode The Offset mode provides fine position adjustment for the color wheel the effects color temperature wheel and the dimmer These fine adjustments allow the operator to position the wheels so the light goes through the center of the color or effect aperture thus preventing any filter border from showing In the case of...

Страница 20: ...WN repeatedly until the display shows 2 Press ENTER The display will start blinking showing the current value 127 127 3 Press UP or DOWN to set the new value 4 Press ENTER to save the new value or MENU to exit without saving Exiting Offset Mode 1 After you are done wait eight seconds for the display timer to activate The display will show the current DMX address ...

Страница 21: ...ider Resuming slider control after blacking out the dimmer is not possible however Shutter The shutter has no fixed position buttons to operate along with the slider This slider has a closed and an open position on the left side while the right side has another open position The shutter frequency changes from short yet separated openings to a fast strobe like action as the slider moves from left t...

Страница 22: ...he external control console when operating this fixture with a third party DMX controller DMX Values 6 Channel DMX Mode Channel Function Value Percent Setting 1 Shutter 000 ó 007 008 ó 015 016 ó 247 248 ó 255 Blackout Open Strobe 1 12 Hz Open 2 Iris 000 ó 254 255 0 100 Closed 3 Color 000 ó 014 015 ó 028 029 ó 042 043 ó 056 057 ó 070 071 ó 084 085 ó 098 099 ó 112 113 ó 127 128 ó 191 192 ó 255 White...

Страница 23: ...very 30 days CHAUVET recommends cleaning the fixture s external optics with a soft cloth using normal glass cleaning fluid Procedure To clean the Followspot 1200 follow the below recommendations Unplug the fixture from power Wait until the fixture is cold 15 minutes minimum Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external vents and reachable internal com...

Страница 24: ...Technical Information Followspot 1200 User Manual Rev 03e 20 April 7 2010 Photometrics ...

Страница 25: ...No power Check for power on outlet Faulty or lose power cord Check power cord Faulty Noise Filter PCB Replace Noise Filter PCB Faulty Main PCB Replace Main PCB Followspot 1200 turns on but lamp does not come up Shutter closed Open shutter Dimmer set to 0 Set dimmer to 100 Faulty lamp Replace lamp Faulty igniter Replace igniter Faulty ballast Replace ballast Faulty Main PCB Replace Main PCB Follows...

Страница 26: ...Technical Information Followspot 1200 User Manual Rev 03e 22 April 7 2010 Exploded View ...

Страница 27: ...handle 25 P100 FS12MP1 Motor Plate 1 79 P100 FS12DCP Die cast part 26 P100 FS12POST Post 80 P100 FS12PFM 10 mm post 27 P100 FS12GAS Gasket 81 P170 FS12ISCW ISC 1200D PCB 28 P100 FS12TCFH Top cover 82 P100 FS12DCPB Bracket die cast part 29 P100 FS12MP2 Motor plate 2 83 P100 FS12HAND Handle 30 P100 FS12BER Bearing 84 P100 FS12LOOP Loop 31 P100 FS12BELT Belt 85 P100 FS12PFM1 10 mm post 32 P100 FS12TC...

Страница 28: ...ting from inadequate packaging is the customer s responsibility As a suggestion proper UPS packing or double boxing is always a safe method to use CHAUVET reserves the right to use its own discretion to repair or replace returned product s Claims The carrier is responsible for any damage incurred during shipping Therefore if the received merchandise appears to have damages caused during shipping t...

Страница 29: ...Power Factor PF 0 71 Fuse External 6 x 30 mm glass 15 A 250 V Light Source Metal Halide Lamp Osram HTI 1200 W D 7 60 6 500 K 2 000 hrs Quantity 1 Photo Optic Luminance 4º angle 202 000 lux 1 m Luminance 13º angle 7 000 lux 5 m 3650 lux 2 7 meter 1800 lux 10 m Beam angle range 4 38 Control Programming Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin conf...

Страница 30: ...e controller would interfere with the signals sent by the other controller s The Functions Each DMX channel can have any unitary value in the 000 255 range Each DMX compatible fixture uses as many consecutive DMX channels as features the user can control The sequential numbers assigned to each DMX channel 1 512 are also known as DMX addresses The function each DMX channel has and the results of it...

Страница 31: ...icates to each fixture However the user should always define a physical location for the fixtures that provides for the easiest and most direct cabling Number of Fixtures When using a DMX controller the combined number of channels required by all the fixtures on the serial data link determines the number of fixtures the DMX controller has to support Conversely the number of onboard sliders page bu...

Страница 32: ...ive signal Pin 2 Pin 2 Positive signal Pin 3 Pin 3 Not Used Pin 4 Not Used Pin 5 DMX Connection Make sure that the fixtures with which you are working can operate in DMX mode not in a proprietary connection mode Refer to the fixtures manual to learn how to enable their respective DMX modes The procedure below illustrates a possible DMX connection method 1 Connect the 3 pin male connector of the fi...

Страница 33: ...at there is no DMX controller involved Refer to the fixtures manual to learn how to configure them to work in Master Slave mode The procedure below illustrates a possible connection method 1 Connect the 3 pin male connector of the first DMX cable to the DMX Output connector 3 pin female of the master fixture 2 Connect the 3 pin female connector of the first DMX cable coming from the master fixture...

Страница 34: ...ser to control simultaneously the whole group of units at that DMX address by setting the ID Addressing channel to 0 Similarly the user can control each fixture at that DMX address independently by first selecting the DMX address and then using the ID Addressing channel to locate the target ID address Single Row ID Addressing Diagram Standard Block Connection In the Standard Block connection the f...

Страница 35: ...act as the PF decreases the difference between the current calculated using the watts volts method and the actual current increases Therefore for fixtures with a PF below 0 9 the installer must always consider the fixture s PF when using the watts figure to calculate the current it draws For the above example if the published fixture s PF were 0 7 the resulting drawn current would be as follows 2 ...

Страница 36: ...CHAUVET 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com Followspot 1200 User Manual Rev 03e April 2010 ...

Отзывы: