AC Power 

The Firebird™ LED has a fixed power supply that works with either a voltage of 120 VAC, 
60 Hz or 240 VAC, 50 Hz. 

 

Always connect the  product  to a protected circuit (circuit breaker or fuse). Make 
sure the product has an appropriate electrical ground to avoid the risk of 
electrocution or fire. 

To eliminate unnecessary wear and improve its lifespan, during periods of non-use 
completely disconnect the product from power via breaker or by unplugging it. 

 

Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if 
the rheostat or dimmer channel serves only as a 0 to 100% switch. 

Fuse 

Replacement 

1.  Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.  

2.  Pry the fuse holder out of the housing. 

3.  Remove the blown fuse from the holder and replace with a fuse of the exact same 

type and rating. 

4.  Insert the fuse holder back in place and reconnect power. 

 

 
 
 
 
 
 
 
 
 
 

 

Disconnect the product from the power outlet before replacing the fuse. 

 

 

 

Ensure the imitation flame silk is completely unrolled before powering the product 
on. 

 

 

Imitation flame silk may not be 2 m in length when product is running. 

 

 

 

Replacing the 

Silk 

 

The imitation flame silk will eventually become tattered from use.  How long it lasts will 
depend on how often it is used and for how long. 

For a replacement imitation flame silk, contact Chauvet Customer Service. See 

Contact Us

 

in this User Manual. 

Upon receiving a replacement silk, follow the instructions below to install it: 

1.  Carefully remove the tattered silk from the silk attachment plate by pulling on the  

hook and loop strip sewn into the silk. Be careful ONLY to remove the tape that is 
sewn into the silk. 

2.  Discard the old silk. 

3.  Align the hook and loop strip sewn into the new silk to the hook and loop strip on the 

silk attachment plate. The closer they are aligned, the stronger the attachment will be. 

Note

: Be careful not to damage or dirty the hook and loop tape on the silk attachment 

plate. 

Installed fuse  

(held by plastic clip) 

Spare fuse holder  

(inside safety cap) 

Safety cap 

Содержание Firebird LED

Страница 1: ...User Manual ...

Страница 2: ...ct Dimensions 6 3 Setup 7 AC Power 7 Fuse Replacement 7 Replacing the Silk 7 4 Operation 8 Control Panel Operation 8 Menu Map 8 DMX Linking 8 Configuration DMX 8 Starting Address 8 DMX Channel Assignments and Values 9 9 Channel Mode 9 Configuration Standalone 9 Wireless Remote Control 9 Programmable Color Selection 10 Color Chart 10 Control from the Display 10 5 Maintenance 11 Product Maintenance ...

Страница 3: ... only one can be chosen Settings A menu option not to be modified Menu Settings A sequence of menu options to be followed ENTER A key to be pressed on the product s control panel ON A value to be entered or selected Symbols Symbol Meaning Critical installation configuration or operation information Not following these instructions may make the product not work cause damage to the product or cause ...

Страница 4: ...n Always make sure that the voltage of the outlet to which you are connecting the product is within the range stated on the decal or rear panel of the product The product is for indoor use only IP20 To prevent risk of fire or shock do not expose the product to rain or moisture Always install the product in a location with adequate ventilation at least 20 in 50 cm from adjacent surfaces Be sure tha...

Страница 5: ...bird LED User Manual Rev 1 Page 5 of 14 2 INTRODUCTION Product Overview DMX In Out Fuse Holder Rubber Mounting Feet Silk Attachment Plate Power Switch Wireless Remote Port Power In Display Menu Buttons LEDs ...

Страница 6: ...Dimensions When the product is running the imitation flame silk flaps to simulate a flame consequently the silk might not extend fully to 2 m in length 20 4 in 518 mm 8 9 in 228 mm 12 8 in 325 mm 78 7 in 2 000 mm 15 in 380 mm 23 6 in 600 mm 0 79 in 20 mm ...

Страница 7: ...ct power Disconnect the product from the power outlet before replacing the fuse Ensure the imitation flame silk is completely unrolled before powering the product on Imitation flame silk may not be 2 m in length when product is running Replacing the Silk The imitation flame silk will eventually become tattered from use How long it lasts will depend on how often it is used and for how long For a re...

Страница 8: ... CHAUVET DMX Primer which is available from the Chauvet website http www chauvetlighting com downloads DMX_Primer_rev05_WO pdf Configuration DMX Set the product in DMX mode to control with a DMX controller 1 Connect the product to a suitable power outlet 2 Connect a DMX cable from the DMX output of the DMX controller to the DMX input socket on the product Starting Address When selecting a starting...

Страница 9: ...tandalone Set the product in one of the standalone modes to control without a DMX controller 1 Connect the product to a suitable power outlet 2 Turn the product on using the power switch Never connect a product that is operating in any standalone mode to a DMX string connected to a DMX controller Products in standalone mode may transmit DMX signals that could interfere with the DMX signals from th...

Страница 10: ... colors snap or fade 4 Press ENTER 5 Repeat steps 1 4 to configure the other buttons The Geyser Wireless Remote Control buttons 1 4 trigger the options set in the color programs menu CH 1 CH 4 respectively Color Chart Preset Red Green Blue Amber Co 1 100 0 0 0 Co 2 0 100 0 0 Co 3 0 0 100 0 Co 4 0 0 0 100 Co 5 100 100 0 0 Co 6 100 25 0 0 Co 7 100 0 0 100 Co 8 100 100 0 100 Co 9 100 0 100 0 Co10 100...

Страница 11: ... To clean the product follow the instructions below 1 Unplug the product from power 2 Wait until the product is at room temperature 3 Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external surface vents 4 Clean all transparent surfaces with a mild soap solution ammonia free glass cleaner or isopropyl alcohol 5 Apply the solution directly to a soft lint free co...

Страница 12: ...z Fixed voltage Parameter 120 V 60 Hz 230 V 50 Hz Consumption 192 W 192 W Operating Current 1 6 A 1 A Fuse F 2 A 250 V F 2 A 250 V Power I O U S Worldwide UK Europe Power input connector IEC IEC Power output connector Edison IEC Power Cord plug Edison U S Local plug Light Source Type Power Lifespan LED 5 W 50 000 hours Color Quantity Current Quad color RGBA 4 1 8 A Photometrics Parameter Strobe Ra...

Страница 13: ...pping the product Be prepared to provide the model number serial number and a brief description of the cause for the return You must send the merchandise prepaid in its original box and with its original packing and accessories Chauvet will not issue call tags Clearly label the package with the RMA number Chauvet will refuse any product returned without an RMA number Write the RMA number on a prop...

Страница 14: ... 1C Brookhill Road Industrial Estate Pinxton Nottingham UK NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 Technical Support Email uktech chauvetlighting com World Wide Web www chauvetlighting co uk MEXICO Chauvet Mexico General Information Address Av Santa Ana 30 Parque Industrial Lerma Lerma Mexico C P 52000 Voice 52 728 285 5000 Technical Support Email servicio chauvet com mx World Wide We...

Отзывы: