13
Mounting
F4 IP User Manual Rev. 1
Flat Wall Installation
Refer to the following diagram for flat wall installation.
The 4 rear and front mounting holes are intended for flush mount installation to a flat
surface against the video panels. 1 mounting point for every junction, including
outside edges and corners, must be used in order to maintain structural integrity.
The mounting points are not intended for hanging or suspending from a truss or
other overhead structure.
Chauvet recommends using a VERTICAL steel strut for each column of panels, plus
1, as in the following diagram:
The illustrations above are examples only. Please refer to all applicable local codes
and regulations for the proper installation of the product.
Mounting Points on a Flat Wall
Rear
Threaded Mounting Holes
Size M12 (x4)
Front
Mounting Holes
Size M10 (x4)
At least 1 mounting point for
every junction (circled above)
must be secured, including
outside edges and corners
M12 bolts must be
used for rear mounting
applications
SAE 3/8 or M10 bolts
are compatible for front
mounting applications
4 c 1
= 5 steel struts