Chauvet DMX-602 Скачать руководство пользователя страница 5

 

DMX-602 User Manual 

2006-02-10/12:12

 

Product Overview 

 

Intimidator

 1.2

 

Mirror Scanner 

Hanging Yoke, double 
bracketed for floor 
positioning 

Double bracketed 
yoke used for floor 
positions.  

Lamp access cover 

Power & Fuse compartment 

Microphone 

Sound Sensitivity Knob 

Remote Controller Input 

DMX connectors 

Dipswitches 

DMX 512 Configuration 

CH1=GOBO 
CH2=COLOR 
CH3=STROBE 
CH4=PAN 
CH5=TILT 

Содержание DMX-602

Страница 1: ...Chauvet 3000 N 29 th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2006 02 10 12 12 DMX 602 Intimidator 1 2 USER MANUAL ...

Страница 2: ...stallation 6 POWER 6 MOUNTING 7 Orientation 7 Rigging 7 MANUAL FOCUSING 7 FUSE REPLACEMENT 7 OPERATING INSTRUCTIONS 8 OPERATING MODES 8 Stand Alone 8 Master Slave 8 Master Slave settings 8 Optional Pan Tilt Inverse 8 DMX Mode 8 Setting the starting address 8 CH X Optional Blackout Controller 9 APPENDIX 10 DMX PRIMER 10 Fixture Linking 10 DMX CHANNEL VALUES 11 MAINTENANCE 12 RETURNS PROCEDURE 12 CL...

Страница 3: ...is User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not expo...

Страница 4: ...in beat activated and automatic programs stand alone Double bracket yoke doubles as floor stand Bulb saver cuts off after 10 seconds Surface coated mirror for optimum luminosity Automatically enters stand alone when no DMX signal is present Linkable via Master Slave Micro stepping motors Thermal switch Fan cooled Options Wired remote controllers CH X blackout controller Programmable Any universal ...

Страница 5: ...nging Yoke double bracketed for floor positioning Double bracketed yoke used for floor positions Lamp access cover Power Fuse compartment Microphone Sound Sensitivity Knob Remote Controller Input DMX connectors Dipswitches DMX 512 Configuration CH1 GOBO CH2 COLOR CH3 STROBE CH4 PAN CH5 TILT ...

Страница 6: ...ge 4 Detach the lamp from the lamp socket and replace 5 Replace lamp cover plate and fasten the screw 6 No lamp alignment is necessary for this fixture since the lamp is already optimized inside the reflector Power Warning Verify that the voltage indicator label on your unit matches the line voltage applied All fixtures must be connected to circuits with a suitable Earth Ground To determine the po...

Страница 7: ...Safety cables should always be used o Never mount in places where the fixture will be exposed to rain high humidity extreme temperature changes or restricted ventilation Manual Focusing To adjust the focus please follow the instructions below 1 If operating in stand alone mode turn the music down so that the unit temporarily stops any activity 2 In DMX control mode create a static scene with any g...

Страница 8: ...setting selections Simply connect each unit in a daisy like fashion using qualified 3 pin DMX cables as described below MASTER SLAVE SETTINGS 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the first fixture 2 Connect the end of the cable coming from the first fixture which will have a female 3 pin connector to the input connector of the next fixtur...

Страница 9: ...itch in the ON position will provide the start address Determining which switches to toggle ON given a specific start address can be accomplished in the following manner By subtracting the largest switch value possible from the selected start address which does not cause a negative number EXAMPLE STARTING ADDRESS Address 10 Pin 4 8 Pin 2 2 Total 10 Address 24 Pin 5 16 Pin 4 8 Total 24 Resolving ad...

Страница 10: ...e fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 while pi...

Страница 11: ... 6 Gobo 7 Gobo 8 Gobo 9 Gobo 10 Gobo 11 Gobo 12 Gobo 13 Gobo 14 Gobo Spin Slow Fast Sound Active 2 000 009 010 019 020 029 030 039 040 049 050 059 060 069 070 079 080 089 090 099 100 109 110 119 120 255 Color White Open Color 1 Color 2 Color 3 Color 4 Color 5 Color 6 Color 7 Color 8 Color 9 Color 10 Color 11 Color Spin Slow Fast 2 000 045 046 115 116 185 186 255 Strobe gobo strobe Open Gobo Color ...

Страница 12: ...n the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prepaid...

Страница 13: ...ible bad lamp or fixture is overheating Lamp may be at end of its life Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again wait 5 to 10 minutes before powering up Loss of signal Use only DMX cables Install terminator Note Keep DMX cables separated from power cables or black lights Motor movements...

Страница 14: ...rong IEC 60320 C14 male socket European version 230V 240V 50 Hz LAMPS ELC 250W 24V THERMAL Maximum ambient temperature 40 104 F FUSE Main 20mm Glass 3 15A Fast Blow CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 5 ORDERING INFORMATION Intimidator 1 2 DMX 60...

Отзывы: