Chauvet DMX-602 Скачать руководство пользователя страница 3

 

DMX-602 User Manual 

2006-02-10/12:12

 

B

EFORE 

Y

OU 

B

EGIN

 

What is included 

 

1 x DMX-602 Intimidator

 

1.2  

 

Power cord with plug 

 

ELC 250w lamp 

 

Warranty Card 

 

Manual

Unpacking Instructions 

Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that 

all parts are present, and have been received in good condition. Notify the shipper immediately and 

retain packing material for inspection if any parts appear damaged from shipping or the carton itself 

shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture 

must be returned to the factory, it is important that the fixture be returned in the original factory box 

and packing. 

AC Power 

To determine the power requirements for a particular fixture, see the label affixed to the back plate of 

the fixture or refer to the fixture

s specifications chart. A fixture

s listed current rating is its average 

current draw under normal conditions. All fixtures must be powered directly off a switched circuit and 

cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer 

channel is used solely for a 0% to 100% switch. Before applying power to a fixture, check that the 

source voltage matches the fixture

s requirement. Check the fixture or device carefully to make sure 

that if a voltage selection switch exists that it is set to the correct line voltage you will use. 

Warning! 

Verify that the voltage indicator label on your unit matches the line voltage applied. 
All fixtures must be connected to circuits with a suitable Earth Ground.  

Safety Instructions 

 

Please keep this User Guide for future consultation. If you 
sell the unit to another user, be sure that they also receive 
this instruction booklet. 

 

Always make sure that you are connecting to the proper 
voltage and that the line voltage you are connecting to is 
not higher than that stated on decal or rear panel of the 
fixture. 

 

This product is intended for indoor use only! 

 

To prevent risk of fire or shock, do not expose fixture to 
rain or moisture. Make sure there are no flammable 
materials close to the unit while operating. 

 

The unit must be installed in a location with adequate 
ventilation, at least 50cm from adjacent surfaces. Be sure 
that no ventilation slots are blocked. 

 

Always disconnect from power source before servicing or 
replacing lamp or fuse and be sure to replace with same 
lamp source. 

 

Secure fixture to fastening device using a safety chain. 
Never carry the fixture solely by its head. Use its carrying 
handles. 

 

Maximum ambient temperature is Ta: 40

°

. Do not operate 

fixture at temperatures higher than this.  

 

In the event of serious operating problem, stop using the 
unit immediately. Never try to repair the unit by yourself. 
Repairs carried out by unskilled people can lead to 
damage or malfunction. Please contact the nearest 
authorized technical assistance center. Always use the 
same type spare parts. 

 

Don

t connect the device to a dimmer pack.

 

 

Make sure power cord is never crimped or damaged. 

 

Never disconnect power cord by pulling or tugging on the 
cord. 

 

Avoid direct eye exposure to lamp while it is on.  

 

Caution! 

There are no user serviceable parts inside the unit. Do not open the housing or 
attempt any repairs yourself. In the unlikely event your unit may require service, 
please contact CHAUVET. 

 

 

 

Please read these instructions carefully, which includes important 

information about the installation, usage and maintenance? 

 

 

Содержание DMX-602

Страница 1: ...Chauvet 3000 N 29 th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2006 02 10 12 12 DMX 602 Intimidator 1 2 USER MANUAL ...

Страница 2: ...stallation 6 POWER 6 MOUNTING 7 Orientation 7 Rigging 7 MANUAL FOCUSING 7 FUSE REPLACEMENT 7 OPERATING INSTRUCTIONS 8 OPERATING MODES 8 Stand Alone 8 Master Slave 8 Master Slave settings 8 Optional Pan Tilt Inverse 8 DMX Mode 8 Setting the starting address 8 CH X Optional Blackout Controller 9 APPENDIX 10 DMX PRIMER 10 Fixture Linking 10 DMX CHANNEL VALUES 11 MAINTENANCE 12 RETURNS PROCEDURE 12 CL...

Страница 3: ...is User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not expo...

Страница 4: ...in beat activated and automatic programs stand alone Double bracket yoke doubles as floor stand Bulb saver cuts off after 10 seconds Surface coated mirror for optimum luminosity Automatically enters stand alone when no DMX signal is present Linkable via Master Slave Micro stepping motors Thermal switch Fan cooled Options Wired remote controllers CH X blackout controller Programmable Any universal ...

Страница 5: ...nging Yoke double bracketed for floor positioning Double bracketed yoke used for floor positions Lamp access cover Power Fuse compartment Microphone Sound Sensitivity Knob Remote Controller Input DMX connectors Dipswitches DMX 512 Configuration CH1 GOBO CH2 COLOR CH3 STROBE CH4 PAN CH5 TILT ...

Страница 6: ...ge 4 Detach the lamp from the lamp socket and replace 5 Replace lamp cover plate and fasten the screw 6 No lamp alignment is necessary for this fixture since the lamp is already optimized inside the reflector Power Warning Verify that the voltage indicator label on your unit matches the line voltage applied All fixtures must be connected to circuits with a suitable Earth Ground To determine the po...

Страница 7: ...Safety cables should always be used o Never mount in places where the fixture will be exposed to rain high humidity extreme temperature changes or restricted ventilation Manual Focusing To adjust the focus please follow the instructions below 1 If operating in stand alone mode turn the music down so that the unit temporarily stops any activity 2 In DMX control mode create a static scene with any g...

Страница 8: ...setting selections Simply connect each unit in a daisy like fashion using qualified 3 pin DMX cables as described below MASTER SLAVE SETTINGS 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the first fixture 2 Connect the end of the cable coming from the first fixture which will have a female 3 pin connector to the input connector of the next fixtur...

Страница 9: ...itch in the ON position will provide the start address Determining which switches to toggle ON given a specific start address can be accomplished in the following manner By subtracting the largest switch value possible from the selected start address which does not cause a negative number EXAMPLE STARTING ADDRESS Address 10 Pin 4 8 Pin 2 2 Total 10 Address 24 Pin 5 16 Pin 4 8 Total 24 Resolving ad...

Страница 10: ...e fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 while pi...

Страница 11: ... 6 Gobo 7 Gobo 8 Gobo 9 Gobo 10 Gobo 11 Gobo 12 Gobo 13 Gobo 14 Gobo Spin Slow Fast Sound Active 2 000 009 010 019 020 029 030 039 040 049 050 059 060 069 070 079 080 089 090 099 100 109 110 119 120 255 Color White Open Color 1 Color 2 Color 3 Color 4 Color 5 Color 6 Color 7 Color 8 Color 9 Color 10 Color 11 Color Spin Slow Fast 2 000 045 046 115 116 185 186 255 Strobe gobo strobe Open Gobo Color ...

Страница 12: ...n the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prepaid...

Страница 13: ...ible bad lamp or fixture is overheating Lamp may be at end of its life Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again wait 5 to 10 minutes before powering up Loss of signal Use only DMX cables Install terminator Note Keep DMX cables separated from power cables or black lights Motor movements...

Страница 14: ...rong IEC 60320 C14 male socket European version 230V 240V 50 Hz LAMPS ELC 250W 24V THERMAL Maximum ambient temperature 40 104 F FUSE Main 20mm Glass 3 15A Fast Blow CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 5 ORDERING INFORMATION Intimidator 1 2 DMX 60...

Отзывы: