AC Power 

 

 

 

This fixture accepts an input of 100~240 VAC, 50/60 Hz. Before powering on the unit, make sure 

the line voltage to which you are connecting it is within the range of accepted voltages. Also 

make sure that the fixtures you are plugging into the DMX-4 LED match the input voltage. 

 

Input voltage equals output voltage. 

 

To determine the power requirements for a particular fixture, see the label affixed to the back 
plate of the fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating 

indicates its average current draw under normal conditions.  

 

 

 

Always connect the fixture to a switched circuit. Never connect the fixture to a rheostat 

(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used only 

as a 0 to 100% switch.

 

 

 

 

Always connect the fixture to a circuit with a suitable electrical ground.  

 

 

 

 

Notes on 

“Switch” Operation 

 

 

 

Dimmer/switch packs are primarily intended for lamp-based PAR cans. Connecting a fixture 
equipped with an electronic (switching) power supply to a dimmer/pack switch may damage the 
fixture or make it work erratically. 
 
The improved DMX-4 LED

’s design now allows you to switch on and off loads equipped with 

electronic power supplies, such as LED-based luminaries or laser fixtures. However, the DMX-4 
LED 

must be in “switch” mode before connecting this type of loads to it. Please see the 

instructions on how to set the DMX-4 LED in switch mode below. 

 

 

 

Always make sure that the DMX-4 LED is in switch mode before connecting a load 
equipped with an electronic power supply to it. Doing otherwise could damage the load. 

 

 

 

 

Changing between “Dimmer” and “Switch” 

 

 

 

The DMX-4 LED has two different methods for controlling the output of the four (4) channels. This 
must be set by the user via the control panel. 
 
Please see the steps below for this procedure. 

 

 

 

1. 

Unplug any units from the four output channels. 

2. 

Plug the DMX-4 LED into power. 

3. 

Press 

<MODE>

 until 



~



 appears on the LED display. 

4. 

Press 

<MENU>

 until 



**

/



**

/



**

/



**

 appears on the LED display. This setting can 

be set differently for each of the four channels. Navigate to the desired channel. 

5. 

Using 

<UP>

 & 

<DOWN>,

 select either 



 or 





 

switches the channel to “switch” 

method. 



 sets it into dimmer method. 

6. 

Continue to set this for each of the 4 channels, using the process detailed in the steps 
above, until complete. 

 

 

 

 

Содержание DMX-4 LED

Страница 1: ...DMX 4 LED User Manual...

Страница 2: ...SETUP 6 AC POWER 6 NOTES ON SWITCH OPERATION 6 CHANGING BETWEEN DIMMER AND SWITCH 6 MOUNTING 7 Orientation 7 Rigging 7 Rigging 8 4 OPERATING INSTRUCTIONS 9 CONFIGURING THE STARTING ADDRESS 9 DMX MODE...

Страница 3: ...ular text CONVENTION MEANING 10 A DIP switch to be configured Menu A key to be pressed on the fixture s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Sett...

Страница 4: ...ct from power source before servicing or replacing fuse and be sure to replace with same fuse source Secure fixture to fastening device using a safety chain Maximum ambient temperature Ta is 104 F 40...

Страница 5: ...2 Introduction 5 12 10 2010 5 16 PM 2 INTRODUCTION Product Overview LED Display Power In Power Switch Control Buttons DMX In DMX Out Channel Outputs 1 4 LED Channel Indicators Fuseholders...

Страница 6: ...er pack switch may damage the fixture or make it work erratically The improved DMX 4 LED s design now allows you to switch on and off loads equipped with electronic power supplies such as LED based lu...

Страница 7: ...manual for a detailed weight listing Mount the fixture securely This may be done with a screw nut and bolt or a hanging clamp The hole in each bracket is 13 mm in size When rigging consider routine ma...

Страница 8: ...a hanging clamp Please see the steps below for further details 1 Unplug power from the product 2 On the back of the product locate the six 6 Edison 2 screws 3 Using a screwdriver remove these 4 The mo...

Страница 9: ...ing UP and DOWN select one of the three personalities 4 Press MENU until the LED display reads 5 Using UP and DOWN select the DMX starting address Standalone Mode This fixture has built in auto progra...

Страница 10: ...255 Dimmer 0 100 2 Channel Personality In this DMX personality the four channels will be grouped into pairs Channels 1 2 will be controlled by DMX channel 1 while channels 3 4 will be controlled by DM...

Страница 11: ...g Damaged DMX cables Check DMX cables Wrong polarity settings on the controller Check polarity switch settings on the controller Loose DMX cables Check cable connections Faulty DMX interface Replace D...

Страница 12: ...pin 2 is Data Negative S and pin 3 is Data positive S Fixture Linking Daisy Chain You will need a daisy chain to run light shows of one or more fixtures using a DMX controller or to run synchronized...

Страница 13: ...read the data on the channel indicated by the start address For example a fixture that uses six DMX channels and was addressed to start on DMX channel 100 would read data from channels 100 101 102 10...

Страница 14: ...4 Not used Pin 5 Setting up a DMX Daisy Chain 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the controller 2 Connect the end of the cable coming fro...

Страница 15: ...king call tags will not be issued Package must be clearly labeled with a Return Merchandize Authorization Number RMA Products returned without the RMA will be refused Call CHAUVET and request an RMA p...

Страница 16: ...PROGRAMMING Data input locking 3 pin XLR female socket Data output locking 3 pin XLR male socket Data pin configuration pin 1 shield pin 2 pin 3 Protocol DMX 512 USITT DMX Channels user configurable...

Отзывы: