What is included 

¾

 Omega 

(DMX-155) 

¾

 

Power cord with plug 

¾

 

Hanging bracket, knobs, bolts and Allen wrench 

¾

 

EFR5 15v 150w (500hrs) lamp 

¾

 

Manual with Warranty Card

Unpacking Instructions 

Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that 

all parts are present, and have been received in good condition. Notify the shipper immediately and 

retain packing material for inspection if any parts appear damaged from shipping or the carton itself 

shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture 

must be returned to the factory, it is important that the fixture be returned in the original factory box 

and packing. 

AC Power 

To determine the power requirements for a particular fixture, see the label affixed to the back plate of 

the fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating is its average 

current draw under normal conditions. All fixtures must be powered directly off a switched circuit and 

cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the 

rheostat or dimmer channel is used solely for a 0% to 100% switch. Before 

applying power to a fixture, check that the source voltage matches the 

fixture’s requirement. Check the fixture or device carefully to make sure that 

if a voltage selection switch exists that it is set to the correct line voltage 

you will use. 

Warning! 

Verify that the power select switch on your unit matches the line voltage applied. All 
fixtures must be connected to circuits with a suitable Earth Ground.  

Safety Instructions 

 

Please keep this User Guide for future consultation. If you 
sell the unit to another user, be sure that they also receive 
this instruction booklet. 

 

Always make sure that you are connecting to the proper 
voltage and that the line voltage you are connecting to is 
not higher than that stated on decal or rear panel of the 
fixture. 

 

This product is intended for indoor use only! 

 

To prevent risk of fire or shock, do not expose fixture to 
rain or moisture. Make sure there are no flammable 
materials close to the unit while operating. 

 

The unit must be installed in a location with adequate 
ventilation, at least 50cm from adjacent surfaces. Be sure 
that no ventilation slots are blocked. 

 

Always disconnect from power source before servicing or 
replacing lamp or fuse and be sure to replace with same 
lamp source. 

 

Secure fixture to fastening device using a safety chain. 
Never carry the fixture solely by its head. Use its carrying 
handles. 

 

Maximum ambient temperature is Ta: 40

°

. Do not operate 

fixture at temperatures higher than this.  

 

In the event of serious operating problem, stop using the 
unit immediately. Never try to repair the unit by yourself. 
Repairs carried out by unskilled people can lead to 
damage or malfunction. Please contact the nearest 
authorized technical assistance center. Always use the 
same type spare parts. 

 

Don’t connect the device to a dimmer pack. 

 

Make sure power cord is never crimped or damaged. 

 

Never disconnect power cord by pulling or tugging on the 
cord. 

 

Avoid direct eye exposure to lamp while it is on.  

 

Caution! 

There are no user serviceable parts inside the unit. Do not open the housing or 
attempt any repairs yourself. In the unlikely event your unit may require service, 
please contact CHAUVET. 

AC Voltage Switch 

 

Please read these instructions carefully, which includes important 

information about the installation, usage and maintenance? 

 

Содержание DMX-155 Omega I

Страница 1: ...CHAUVET 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com DMX 155 Omega I USER MANUAL ...

Страница 2: ...tallation 6 POWER 6 MOUNTING 7 Orientation 7 Rigging 7 MANUAL FOCUSING 7 FUSE REPLACEMENT 7 OPERATING INSTRUCTIONS 8 OPERATING MODES 8 Stand Alone 8 Master Slave 8 Master Slave settings 8 DMX Mode 8 Setting the starting address 8 Pan Tilt Invert 9 APPENDIX 10 DMX PRIMER 10 Fixture Linking 10 DMX CHANNEL VALUES 11 ABOUT STROBE GOBO STROBE 11 MAINTENANCE 12 RETURNS PROCEDURE 12 CLAIMS 12 GENERAL TRO...

Страница 3: ...Please keep this User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or sho...

Страница 4: ...icro stepping motors built in beat activated programs built in microphone automatically enters stand alone mode when no DMX signal is present fan cooled linkable via master slave controller programmable via any universal DMX controller thermal switch switch selectable power setting 115V 230V 2 year warranty DMX Channel Summary CHANNEL FUNCTION 1 Color Gobo 2 Strobe 3 Pan 4 Tilt ...

Страница 5: ...blackout controller Safety Hook Attach safety cable to this hook Audio Sensitivity POT Adjust audio sensitivity to improve fixture response Integrated Mic Dipswitches Provided for DMX channel addressing Voltage Selector Choose either 115V or 230V operation Power Input Fuse Holder Manual Focus Lens Gun Hanging Bracket Yoke Yoke tensioning knob Lamp cover Top plate Fan Bottom of fixture ...

Страница 6: ...e lamp socket and follow the same procedure as above to insert lamp into lamp cage 5 Replace top cover and screws 6 No lamp alignment is necessary for this fixture Power Your product is equipped with switch selectable AC power setting Warning Verify that the power select switch on your unit matches the line voltage applied All fixtures must be connected to circuits with a suitable Earth Ground To ...

Страница 7: ...fety cables should always be used Never mount in places where the fixture will be exposed to rain high humidity extreme temperature changes or restricted ventilation Manual Focusing To adjust the focus please follow the instructions below 1 If operating in stand alone mode turn the music down so that the unit temporarily stops any activity 2 In DMX control mode create a static scene with any gobo ...

Страница 8: ...chain will allow a blackout function Connecting the Omega I for Master Slave operation does not require any menu or setting selections Simply connect each Omega I in a daisy like fashion using qualified 3 pin DMX cables as described below MASTER SLAVE SETTINGS 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the first fixture 2 Connect the end of the...

Страница 9: ...the selected start address which does not cause a negative number Pan Tilt Invert This feature allows the user to reverse the Pan and Tilt movement on each fixture regardless of the operating mode Only the mirror movement would be affected by this setting You will notice that the fixture s mirror home setting upon initializing would be set completely opposite of the others not set to Invert Set di...

Страница 10: ...f one fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 whil...

Страница 11: ... activated mode 2 000 Ù 009 010 Ù 045 046 Ù 115 116 Ù 150 151 Ù 185 186 Ù 220 221 Ù 255 Strobe Gobo Strobe Open Strobe Speed 1 Strobe Speed 2 Strobe Speed 3 Strobe Speed 4 Strobe Speed 5 Strobe Speed 6 3 000 Ù 255 Pan Left Right 128 Center 4 000 Ù 255 Tilt Down Up 128 Center About Strobe Gobo Strobe The Omega I shares the strobe function on the color gobo combo wheel To achieve a flash type strobe...

Страница 12: ...n the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prepaid...

Страница 13: ...io provided via jack make sure a live audio signal exists Adjust sound sensitivity knob 9 9 9 Lamps cuts off sporadically Possible bad lamp or fixture is overheating Lamp may be at end of its life 9 Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again wait 5 to 10 minutes before powering up 9 Loss...

Страница 14: ...C input 3 prong IEC 60320 C14 LAMPS EFR5 500 hrs 150W 15V THERMAL Maximum ambient temperature 40 104 F FUSE Main 115V 20mm Glass 3 15A Fast Blow Main 230V 20mm Glass 1 6A Fast Blow CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 4 ORDERING INFORMATION Omega I DMX 15...

Отзывы: