 The fuse is located 
inside this 
compartment. 
Remove using a flat 
head screwdriver. 

3.

 

S

ETUP

 

Fuse Replacement 

1. 

With a flat head screwdriver, wedge the 

fuse holder out of its housing.  

2. 

Remove the damaged fuse from its holder 

and replace with exact same type fuse.  

3. 

Insert the fuse holder back in its place, and reconnect power.  

 

Fixture Linking 

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller 

or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The 

combined number of channels required by all the fixtures on a serial data link determines the number 

of fixtures the data link can support.  

Important:  

Fixtures on a serial data link must be daisy chained in one single line. To comply with the EIA-485 

standard no more than 32 devices should be connected on one data link. Connecting more than 32 

fixtures on one serial data link without the use of a DMX optically-isolated splitter may result in 

deterioration of the digital DMX signal.  

Maximum recommended serial data link distance: 500 meters (1640 ft.) 

Maximum recommended number of fixtures on a serial data link: 32 fixtures 

Data Cabling 

To link fixtures together you must obtain data cables. You can purchase CHAUVET-certified DMX 

cables directly from a dealer/distributor or construct your own cable. If you choose to create your own 

cable please use data-grade cables that can carry a high quality signal and are less prone to 

electromagnetic interference. 

D M X  D AT A  C AB L E  

Use a Belden© 9841 or equivalent cable which meets the specifications for EIA RS-485 applications. 

Standard microphone cables cannot transmit DMX data reliably over long distances. The cable must 

have the following characteristics: 

2-conductor twisted pair plus a shield 
Maximum capacitance between conductors 

– 30 pF/ft. 

Maximum capacitance between conductor and shield 

– 55 pF/ft. 

Maximum resistance of 20 ohms / 1000 ft. 
Nominal impedance 100 

– 140 ohms 

 

 

Disconnect the power cord before replacing a fuse and always 
replace with the same type fuse. 

 

 

Содержание DIAMONDstrip Mini

Страница 1: ...33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com USER MANUAL Snapshot Use on Dimmer Outdoor Use Sound Activated DMX Master Slave Auto ranging Power Supply Replaceable Fuse User Serviceable Duty Cycle ...

Страница 2: ... 8 DMX Data Cable 8 Cable Connectors 9 3 Pin to 5 Pin Conversion Chart 9 Setting up a DMX Serial Data Link 9 Master Slave Fixture Linking 10 Mounting 10 Orientation 10 Rigging 10 4 Operating Instructions 11 Using the control panel 11 Control Panel Modes Functions 11 Master Slave Stand Alone 12 Built in programs detailed 12 DMX Control Mode 13 DMX Channel Values 14 General Troubleshooting 15 Contac...

Страница 3: ...and all packing materials In the event that a fixture must be returned to the factory it is important that the fixture be returned in the original factory box and packing AC Power This fixture has an auto switching power supply that can accommodate a wide range of input voltages The only thing necessary to do before powering on the unit is to make sure the line voltage you are applying is within t...

Страница 4: ...erature Ta is 104 F 40 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts Never connect the device ...

Страница 5: ...ctive programs via master slave or DMX ADDITIONAL FEATURES Additional power output max 32 units 120V Additional slave output allows for runway effect up to 31 units OPTIONS COLORstrip Foot Controller LED FS1 DMX Channel Summary CH DESCRIPTION 1 DMX 000 079 Static flashing zones 2 No Function 3 Flash Speed 4 No Function CH DESCRIPTION 1 DMX 220 255 Chase Fade and Auto Run 2 Run Fade Speed 3 No Func...

Страница 6: ...ct Overview Control Panel rear See view below LEDs Mounting Brackets Power Output IEC Power Connector with Fuse Holder DMX In DMX Out Foot controller Input Optional Accessory LED FS1 Sound Sensitivity Adjustment Microphone Master Slave Output Control Panel ...

Страница 7: ...DIAMONDstrip Mini User Manual 7 1 26 2010 2 58 PM Product Dimensions ...

Страница 8: ...serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal Maximum recommended serial data link distance 500 meters 1640 ft Maximum recommended number of fixtures on a serial data link 32 fixtures Data Cabling To link fixtures together you must obtain data cables You can purchase CHAUVET certified DMX cables directly from a dealer di...

Страница 9: ...IN CONVERSION CHART Conductor 3 Pin Female output 5 Pin Male Input Ground Shield Pin 1 Pin 1 Data signal Pin 2 Pin 2 Data signal Pin 3 Pin 3 Do not use Pin 4 Do not use Pin 5 Setting up a DMX Serial Data Link 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the controller 2 Connect the end of the cable coming from the controller which will have a fem...

Страница 10: ...nd of the cable coming from the first fixture which will have a female 3 pin connector to the input connector of the next fixture consisting of a male 3 pin connector Then proceed to connect from the output as stated above to the input of the following fixture and so on Mounting ORIENTATION This fixture may be mounted in any safe position RIGGING Mount the fixture using a suitable C or O type clam...

Страница 11: ...ons MODE FUNCTION PROGRAM FUNCTION PROGRAM P RUN SPEED F FLASH SPEED C COLOR 4 AACt 5 A000 023 000 Blackout 001 Zone 1 000 100 002 Zone 2 000 100 003 Zone 3 000 100 004 Zones 1 2 000 100 005 Zones 1 3 000 100 006 Zones 2 3 000 100 007 Zones 1 2 3 000 100 008 Chase 1 Automatic 000 050 Sound Active 051 100 000 100 009 Chase 2 000 100 010 Chase 3 000 100 011 Chase 4 000 100 012 Chase 5 013 Chase 6 01...

Страница 12: ...3 022 White fade P Run speed MASTER UNIT Settings Press the Mode button Then by using the Up Down buttons select then press the Enter button Select programs by using the Up Down buttons Press the Enter button Some programs have additional controls such as flash and run speed Press the Mode button to toggle additional functions then use the Up Down buttons to change values Refer to the Control Pane...

Страница 13: ... will have a female 3 pin connector to the input connector of the next fixture consisting of a male 3 pin connector Then proceed to connect from the output as stated above to the input of the following fixture and so on DMX mode setup 1 Press the Mode button until the display reads SYS then press Enter 2 Press the Up Down buttons until the display reads S dAd then press Enter 3 Set the DMX address...

Страница 14: ...019 020 029 030 039 040 049 050 059 060 069 070 079 Static Blackout White 1 White 2 White 3 White 4 White 5 White 6 White Full Flash Speed 000 249 Sound Active 250 255 080 089 090 099 100 109 110 119 120 129 130 139 Changes Chase 1 Chase 2 Chase 3 Chase 4 Chase 5 Chase 6 Run Speed Automatic 000 127 Sound Active 128 255 Flash Speed 000 249 Sound Active 250 255 140 149 150 159 160 169 170 179 180 18...

Страница 15: ...ailure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again wait 5 to 10 minutes before powering up Loss of signal Use only DMX cables Install terminator Note Keep DMX cables separated from power cables or black lights No light output Check fuse Call service technician If you still have a problem after trying the above solutions please con...

Страница 16: ...ever control multiple fixtures of the same type using the same starting address as long as the intended result is that of unison movement or operation In other words the fixtures will be slaved together and all respond exactly the same DMX fixtures are designed to receive data through a serial Daisy Chain A Daisy Chain connection is where the DATA OUT of one fixture connects to the DATA IN of the ...

Страница 17: ...optics at least every 20 days Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RMA Products returned without an RMA will be refused Call CHAUVET and request RMA prior to shipping the fixture Be prepared to provide the model number serial number and a br...

Страница 18: ...3A 230V Power Output 32 units max 120V 60 units max 230V COOLING Convection cooled LIGHT SOURCE LED 192 white 100 000hrs PHOTO OPTIC Luminance 1m 1 120 lux Beam Angle 37 x33 Field Angle 68 x51 THERMAL Maximum ambient temperature 104 F 40 C CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protoco...

Отзывы: