COLORado™ 2 User Manual
16
2009-02-18 12:45 PM
DMX Address: 001
ID Address: 01
DMX Address: 001
ID Address: 02
DMX Address: 001
ID Address: 03
DMX Address: 013
ID Address: 01
DMX Address: 013
ID Address: 02
DMX Address: 013
ID Address: 03
DMX 512 Controller
The figure above shows a simple DMX layout which has used three units at each
DMX address. The three units have different ID addresses which allows the user to
collectively control the whole group of units at that DMX address by setting Channel
10 to 0, or to control each unit independently by first selecting the DMX address and
then by using Channel 11 to locate the target ID address. (Note that when using ID
addresses it is also possible to activate ADAS which allows for even more option with
DMX addressing and control.
DMX-512 addressing with ID address
1.
Follow instructions 1 ~ 4 for DMX512 addressing.
2.
Activate ID addressing in each fixture by setting panel function {
ID ON/OFF
} to ON.
{
MENU
}
{
Settings
)
{
ID ON/OFF
}
[ON]
3.
For every DMX512 starting address the user can set 66 separate ID addresses.
4.
Set ID addresses in each fixture by setting panel function {
ID address
} to incremental values.
(I.e. 1,2,3,4,5,6,etc…)
{
MENU
}
{
Settings
}
{
ID address
}
[01 ~ 66]
5.
ID addresses are accessible using Channel 9 [STAG].