background image

 

Chauvet, 3000 N 29

th

 Ct, Hollywood, FL 33020 U.S.A.  

(800) 762-1084 – (954) 929-1115 

FAX (954) 929-5560 

www.chauvetlighting.com

 

 

COLORado

™ 2 

 

 

 

 

 

 
 
 
 
 

 
 
 
 
 

USER MANUAL 

 

 

 
 
 
 
 

 

 

Snapshot 

OK on Dimmer 

 

Outdoor OK 

 

Sound Activated 

 

DMX512 

 

Master/Slave 

 

Autoswitching 

Transformer 

 

Replaceable Fuse 

 

User Serviceable 

 

Duty Cycle 

 

Содержание Colorado 2 Zoom Tour

Страница 1: ...020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com COLORado 2 USER MANUAL Snapshot OK on Dimmer Outdoor OK Sound Activated DMX512 Master Slave Autoswitching Transformer Replaceable Fuse User Serviceable Duty Cycle ...

Страница 2: ... Cable Connectors 13 3 Pin to 5 Pin Conversion Chart 14 Setting up a DMX Serial Data Link 14 Master Slave Fixture Linking 14 4 Operating Instructions 15 Control Options 15 COLORado Control Quick Setup 15 DMX 512 control without ID address 15 DMX 512 addressing with ID address 16 Setting the DMX address 17 Control Panel Functions 17 Menu Map 18 DMX512 Channel Values 19 STAG 19 Important Notes about...

Страница 3: ...r the carton itself shows signs of mishandling Save the carton and all packing materials In the event that a fixture must be returned to the factory it is important that the fixture be returned in the original factory box and packing AC Power This fixture has an auto switching power supply that can accommodate a wide range of input voltages The only thing necessary to do before powering on the uni...

Страница 4: ... lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts Never connect the device to a dimmer pack Make sure the power cord is never crimped or damaged Never disconnect the power cord by pulling or tugging on the cord Avoid direct eye exposure to the light source while it is on Do not daisy chain power to more than 10 uni...

Страница 5: ...nel RGBW ID dimmer strobe macro auto auto speed custom dimmer speed RGBW color mixing with or without DMX controller Color temperature presets 3 200ºK 10 000ºK Built in automated programs via DMX Recall custom programs via DMX Additional Features High power 2W 3W 750mA 1000mA LEDs Ingress Protection IP66 Adjustable barn doors to direct output includes gel frame LED display with lock out feature Po...

Страница 6: ... panel Please see section on Control Panel Functions on a description on how to accomplish this STAG CHANNEL DESCRIPTION 1 Dimmer 2 Red step time when cus 01 10 in ch 8 is activated 3 Green fade time when cus 01 10 in ch 8 is activated 4 Blue 5 White 6 Color Macro White Balance Hyper Color 7 Strobe 8 Auto Custom Programs 9 Auto Speed Adjustment 10 Dimmer Speed 11 ID Address Selection ARC 1 CHANNEL...

Страница 7: ...al 7 2 18 2009 12 45 PM AR2 D CHANNEL DESCRIPTION 1 Dimmer 2 Red 3 Green 4 Blue 5 White AR2 S CHANNEL DESCRIPTION 1 Dimmer 2 Red 3 Green 4 Blue 5 White 6 Strobe HSV CHANNEL DESCRIPTION 1 Hue 2 Saturation 3 Value Intensity ...

Страница 8: ...COLORado 2 User Manual 8 2 18 2009 12 45 PM Power Link Out DMX in Power in Power out Control board DMX out Safety attachment Product Overview ...

Страница 9: ...COLORado 2 User Manual 9 2 18 2009 12 45 PM Dimensions Hanging bracket floor stand Bracket adjustment knob ...

Страница 10: ...riable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch This fixture is designed for power linking from one COLORado 2 to another COLORado 2 fixture Each fixture ships with IP 66 proprietary power input cables Each fixture ships with a power adapter to Male Edison connector Warning All fixtures must be connected to circuits with a suitable Eart...

Страница 11: ...ing then you must use at least 1 safety cable chain for each fixture in addition to the mounting brackets 1 If hanging the fixture for over head use then please follow the below steps 2 Block access below the work area and use suitable and stable platform when installing or servicing fixture 3 Safety cables must always be used secured through safety cable attachment The safety cable must be capabl...

Страница 12: ...lass cover 4 After removing the glass cover remove the screws that hold the lens assembly in place There are 6 Phillips 2 screws that secure this assembly in position Note use care when performing this procedure as this gives you direct access to the LEDs which are very fragile 5 You now should have full access to the lens assembly This must be removed and the old lenses must be replaced with the ...

Страница 13: ... use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DMX DATA CABLE Use a Belden 9841 or equivalent cable which meets the specifications for EIA RS 485 applications Standard microphone cables cannot transmit DMX data reliably over long distances The cable will have the following characteristics 2 conductor twisted pair plus a shield Maximum...

Страница 14: ...ield Pin 1 Pin 1 Data signal Pin 2 Pin 2 Data signal Pin 3 Pin 3 Do not use Do not use Do not use Do not use Setting up a DMX Serial Data Link 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the controller 2 Connect the end of the cable coming from the controller which will have a female 3 pin connector to the input connector of the next fixture con...

Страница 15: ...tled Display Panel Functions These steps assume that you have read and are familiar with setting up a DMX serial data link DMX 512 control without ID address The COLORado 2 operates on 11 channels of DMX STAG personality Address each fixture in increments of 9 channels I e 1 12 23 34 etc To save time you can use the same DMX address for each fixture All fixtures will then respond simultaneously to...

Страница 16: ...unit independently by first selecting the DMX address and then by using Channel 11 to locate the target ID address Note that when using ID addresses it is also possible to activate ADAS which allows for even more option with DMX addressing and control DMX 512 addressing with ID address 1 Follow instructions 1 4 for DMX512 addressing 2 Activate ID addressing in each fixture by setting panel functio...

Страница 17: ... not overlap and note the start address selected for future reference The COLORado 2 uses up to11 channels of DMX If this is your first time using DMX we recommend reading the DMX Primer in the Appendix Section Control Panel Functions All fixture functions and settings are accessible via the built in control panel interface BUTTON FUNCTION MENU Exits from the current menu or function SET Enables t...

Страница 18: ...GB D Arc 2 4 channel RGBW Ar2 d 5 channel RGBW D Ar2 s 6 channel RGBW D strobe 6 ID Address 0 66 Assigns the ID address to a fixture 7 Settings ID On Off Enables or disables ID ADAS Upload Password required Performs an upload of the custom programs to another fixture Displays End when successful Dimmer Off Select linear dimmer by off or special dimmer speed dim1 4 dim1 is the fastest dimming curve...

Страница 19: ... 150 151 170 171 190 191 200 201 205 206 210 211 215 216 220 221 225 226 230 231 235 236 240 241 245 246 250 251 255 Color Macro White Balance HyperColor No Function HyperColor Mode only in Normal power mode No Function Red 100 Green Up Blue 0 Red Down Green 100 Blue 0 Red 0 Green 100 Blue Up Red 100 Green 0 Blue Down Red 0 Green Down Blue 100 Red Up Green 0 Blue 100 Red 100 Green 0 Blue Down Red ...

Страница 20: ...ng curve 3 Nonlinear dimming curve 4 slowest CHANNEL 11 ID ADDRESS SELECTION 000 009 010 019 020 029 030 039 040 049 050 059 060 069 070 079 080 089 090 099 100 109 110 119 120 129 130 139 140 149 150 159 160 169 170 179 180 189 190 199 200 209 210 211 All IDs ID 1 ID 2 ID 3 ID 4 ID 5 ID 6 ID 7 ID 8 ID 9 ID 10 ID 11 ID 12 ID 13 ID 14 ID 15 ID 16 ID 17 ID 18 ID 19 ID 20 ID 21 ID 22 212 213 214 215 ...

Страница 21: ...COLOR MACROS Channel 6 selects the required Color Macro Channel 6 has priority over Channels 2 3 4 5 7 Channel 1 is used to control the intensity of the current Color Macro ID ADDRESS SELECTION Use channel 11 to select ID addressed fixtures Each independent DMX address can have up to 66 ID addressed fixtures ID address 0 allows control of all fixtures simultaneously AUTO CUSTOM PROGRAMS Chanel 8 s...

Страница 22: ...saturation is at 100 then the color is at its purest Value is the color s brightness when value is at 100 then the color is at its brightest Ar2 s CHANNEL VALUE FUNCTION 1 000 255 Hue 0 100 2 000 255 Saturation 0 100 3 000 255 Value 0 100 CHANNEL VALUE FUNCTION 1 000 255 Dimmer 0 100 2 000 255 Red 0 100 3 000 255 Green 0 100 4 000 255 Blue 0 100 5 000 255 White 0 100 6 000 255 Strobe 0 20Hz ...

Страница 23: ... 100 CHANNEL VALUE FUNCTION 1 000 255 Dimmer 0 100 2 000 255 Red 0 100 3 000 255 Green 0 100 4 000 255 Blue 0 100 CHANNEL VALUE FUNCTION 1 000 255 Red 0 100 2 000 255 Green 0 100 3 000 255 Blue 0 100 4 000 255 White 0 100 CHANNEL VALUE FUNCTION 1 000 255 Dimmer 0 100 2 000 255 Red 0 100 3 000 255 Green 0 100 4 000 255 Blue 0 100 5 000 255 White 0 100 ...

Страница 24: ...r control multiple fixtures of the same type using the same starting address as long as the intended result is that of unison movement or operation In other words the fixtures will be slaved together and all respond exactly the same DMX fixtures are designed to receive data through a serial Daisy Chain A Daisy Chain connection is where the DATA OUT of one fixture connects to the DATA IN of the nex...

Страница 25: ... fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RA Products returned without an RMA will be refused Call CHAUVET ...

Страница 26: ...COLORado 2 User Manual 26 2009 02 18 12 45 PM Photometrics ...

Страница 27: ...short in the electrical wiring internal and or external Device has no power Check device s fuse internal Check for power on Mains Check cable connections The COLORado Panel IP 66 cables must be firmly connected and locked in place for operation Note In the event of autoswitching transformer failure the unit can be sent in for repair however a replacement part can be ordered directly from Chauvet P...

Страница 28: ...mation CHAUVET 3000 North 29th Court Hollywood FL 33020 voice 954 929 1115 fax 954 929 5560 toll free 800 762 1084 Technical Support CHAUVET 3000 North 29th Court Hollywood FL 33020 voice 954 929 1115 Press 4 fax 954 929 5560 Attention Service World Wide Web www chauvetlighting com ...

Страница 29: ...ion 5 LED Metal Core PCB assembly P222 C2LEDP 6 Hanging bracket Floor stand P111 C2BRKT 7 Electronic transformer P140 C2ELTR 8 5V voltage regulator PCB P170 5VREGP 9 Display PCB P170 C2DISP 10 LED Driver PCB master P172 C2DRVR 11 Control Board cover P111 C2CVR 12 Cable strain relief watertight seal DMX P111 C2CSSIG 12 Cable strain relief watertight seal power P111 C2CSPWR 13 Display Master IC chip...

Страница 30: ...0V 20 units max 230V LIGHT SOURCE LED 48 12 750mA Red 12 1 000mA Green 12 1 000mA Blue 12 1 000mA White 50 000 hrs Refresh rate 400Hz PHOTO OPTIC Luminance 1m with included 15 degree lenses 12 350 lux Beam Angle 2m with included 15 degree lenses 17 Field Angle 2m with included 15 degree lenses 34 THERMAL Maximum ambient temperature 104 F 40 C CONTROL PROGRAMMING Data input locking 3 pin XLR male s...