Page 5 of 31
ÉPIX Drive 2000 IP User Manual Rev. 2
Setup
3. Setup
AC Power
Each ÉPIX Drive 2000 IP has an auto-ranging power supply that works with an input voltage range of 100
to 240 VAC, 50/60 Hz. To determine the power requirements for each ÉPIX Drive 2000 IP, refer to the label
affixed to the product. You can also refer to the
Technical Specifications
chart in this manual.
The listed current rating indicates the maximum current draw during normal operation. For more
information, download Sizing Circuit Breakers from the Chauvet website:
www.chauvetprofessional.com
.
AC Plug
The ÉPIX Drive 2000 IP comes with a power input cord terminated with a Seetronic Powerkon IP65
connector on one end and an Edison plug on the other end (U.S. market). If the power input cord that
came with your product has no plug, or if you need the change the plug, use the table below to wire the
new plug.
Power Linking
The product supports power linking. You can power link up to 3 products at 120 V; up to 5 at 208 V or 230 V.
This product comes with a power input cord. Power linking cables are available from Chauvet for purchase.
• Always connect the product to a protected circuit (circuit breaker or fuse). Make
sure the product has an appropriate electrical ground to avoid the risk of
electrocution or fire.
• To eliminate unnecessary wear and improve its lifespan, during periods of non-use
completely disconnect the product from power via breaker or by unplugging it.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if
the rheostat or dimmer channel serves only as a 0 to 100% switch.
Connection
Wire (U.S.)
Wire (Europe)
Screw Color
AC Live
Black
Brown
Yellow or Brass
AC Neutral
White
Blue
Silver
AC Ground
Green/Yellow
Green/Yellow
Green
• To preserve the IP65 rating and the warranty of this product Seetronic Powerkon
cables must be used.
• Insert the attached IP65 rated plugs into the corresponding power/data
connections when not in use.