The Neo Vacuum Module is installed into the back of the 

Neo Therapy System Cart.  A ribbon cable is plugged into 

the circuit board in the back of the Neo Head after the 

Head Unit has been installed.  Refer to the Neo Therapy 

System Cart Manual, Item # 13-7782 for proper installation 

instructions for the Cart.

NOTE:

  The Neo Vacuum Module is to be installed only by 

authorized DJO Service Persons. 

NOTE:

  The Neo Vacuum Module will not operate unless a 

Stimulation Module is installed. 

Items included in this module:

Vacuum Module – PN 70006

•  Vacuum hoses 1&2

•  Vacuum hoses 3&4

•  60mm electrodes 

•  60mm Sponges

Tools required (not included): 

• 

#2 Phillips screwdriver 

The System is programmed to automatically recognize 

the new Module, therefore, no software installation or 

configuration is required.

Complete the following steps to install the module:
1.  Power off device.  Remove the power cord from the 

rear of the device.

2.  Remove the back panel from the Cart.  

• 

Pull the top drawer open.  Press the plastic tabs 

on both drawer slides simultaneously in opposite 

directions, as indicated on the slider.  Pull the drawer 

completely out.

•  Remove the four (4) screws where they attach to the 

inside of the Cart.  Retain for use when attaching the 

Vacuum Module. 

• 

Remove the back panel from the cart.

MODULE INSTALLATION

Содержание Neo Vacuum Module

Страница 1: ...oglobal eu fr_FR index html 2017 DJO LLC All rights reserved NeoVacuum Module Manual 13 8809 Rev E For complete User Operating Instructions including Cautions Warnings Dangers Indications and Contraindications refer to the Intelect Neo ClinicalTherapy System User Manual Item 13 7651 CDVersion item 13 7652 To obtain a copy contact your local representative or DJO Customer Care 0086 ...

Страница 2: ... 70006 Vacuum hoses 1 2 Vacuum hoses 3 4 60mm electrodes 60mm Sponges Tools required not included 2 Phillips screwdriver The System is programmed to automatically recognize the new Module therefore no software installation or configuration is required Complete the following steps to install the module 1 Power off device Remove the power cord from the rear of the device 2 Remove the back panel from...

Страница 3: ...ach side of the handle Remove the back panel from the Neo Head 4 Insert the Vacuum Module into the Cart as shown Attach the Vacuum Module with the four 2 Phillips screws removed from the back panel in Step 2 5 Thread the Ribbon Cable up to the receptacle on the circuit board plug in and secure with locking clips as shown If needed remove the cable between the power supply and the board prior to se...

Страница 4: ... Intelect Neo Clinical Therapy System User Manual item 13 7651 for instructions on installing faceplates 9 Replace the Drawer 10 Reconnect the power cord to the rear of the device MODULE INSTALLATION CONTINUED DONOTpermitforeignmaterials liquidsorcleaningagentstoentertheunit including butnotlimitedto inflammables water andmetallicobjectsfrom enteringtheunit topreventunitdamage malfunction electric...

Страница 5: ...ntenance installation removalorreplacementprocedurestoprevent electricalshockandpossibledamagetosystem Vacuumelectrodesshouldnotbeusedonpatientswiththin paperyskin Vacuummayleadtocontactdifficultyandbruising Vacuumelectrodesarenotsuitableforpatientswhoaretakingsteroids dueto thelikelihoodofbruising Handle cleananddisposeofcomponentsandaccessoriesthat havecomeincontactwithbodilyfluidsaccordingtoNat...

Отзывы: