13
®
seal. The seal for the rear outlet is a length of adhesive backed
fibre webbing supplied with instructions ref: TIS093. This is applied
to the flue collar or the Vertical Rear Flue adapter for rear outlet
installations. For top outlet installations, the blanking plate must be
removed, have the webbing fitted to its sealing face, and fitted to
the rear flue outlet. Ensure that the fold on the clamping plate is
in line with the lugs on the firebox as shown in Fig 11. Ensure that
the clamping plate does not prevent the throat plate from seating
correctly. All flue connections must be well sealed. The top outlet
connection is made directly to the cast top, the Skye is supplied with
a flue collar for rear outlet installations.
Fig.7. Vertical register plate with bricked up fireplace
Fig.8. Horizontal register plate with rear flue connection
Fig. 9. Horizontal register plate with top flue connection
Fig. 10. Horizontal register plate with optional vertical rear flue
connector
SOOT DOORS
It is possible to pass a 16 inch diameter sweeps brush through the
appliance but in most back outlet installations it will be necessary to
have a soot door to enable the chimney to be swept. The optional
vertical rear flue connector does allow the chimney to be swept
through the stove. Soot doors may either be in the actual brickwork
of the chimney or in the register plate. Various positions of soot
doors are shown in Figs. 7 to 10.
Alternative
Soot Door Positions
Register Plate
With Soot Door
Soot Door
In Side or Rear
Of Chimney
Register Plate
Alternative
Soot Door Positions
Register Plate
With Soot Door
Alternative
Soot Door Positions
Register Plate
With Soot Door
160mm Skye 5
180mm Skye 7
(Spacer required,
Part no 77 pages
20-21)