background image

 

Issue F

 

 

13

®

charnwood

T:+44  (0)1983  537799  •  F:+44  (0)1983  537788  •  [email protected]  •  WWW.CHARNWOOD.COM 

  BISHOPS  WAY,  NEWPORT,  ISLE  OF  WIGHT    PO30  5WS,  UNITED  KINGDOM

®

LA10  PARTS LIST

To obtain spare parts please contact your local stockist 
giving Model, Part No. and Description. In case of 
difficulty contact the manufacturer at the address 
shown.

charnwood

Item

Part No.

Description

Item

Part No.

Description

1*

008/PV21

Door Seal

26#

002/FR001/A Door Assembly

2*

008/FW29

Door Seal Adhesive

27

010/FR016

Latch Bracket

3*

008/PV55

Glass Seal Kit

28

008/FR018

Airwash Control Knob

4

006/PV19

Glass (Inc Seal)

29

004/EY48

Airwash Slide

5

004/KV23

Glass Retainer (Top)

30#

002/PV12B

Flue Collar

6

004/FR020

Glass Retainer (Lower)

31

012/PV09

Blanking Plate

7

010/PV31

Throat Plate

32

010/EY51

Clamping Plate

8

010/BR059L

L.H.Side Fire Plate Inc Gasket

33#

010/PV33

Vertical Rear Flue Adapter (Optional Extra)

9

010/BR059R

R.H. Side Fire Plate Inc Gasket

34

012/BV20/A

Ashpan/Door Opening Tool

10

010/FR058

Back Fire Plate Inc Gasket

35

004/DY22

Riddler Blanking Disc

11

010/FR008

Fence Assembly

36

012/FR011

Serial No Label

12

002/EY24

Wood Ash Retainer

37#

001/FR010

Firebox

13

008/FR017

Air Slide Knob

38

010/EY20

Grate Kit (Optional Extra)

14

010/FR002

Air Slide

39

002/EY03

Grate Plate

15

002/FR003

Handle Casting

40

010/EY09

Rear Grate Support

16

008/FR012

Wooden Handle

41

010/EY06

Front Grate Support

17

008/FFB007

M8 x 100mm Socket Head Bolt

42

010/EY04

L.H. Side Grate Support

18

008/FFW015

M12 Double Coil Spring Washer

43

010/EY05

R.H. Side Grate Support

19

008/FFN001

M12 Nut

44

010/EY13

Riddler Rod Assembly

20

008/FFW008

M12 Washer

45

004/PV17

Ashpan

21

004/ST008

Tab Washer

46

008/DY23

Riddler Rod Retaining Clips

22

002/AY14

Door Catch

47

002/DY21

Riddler Knob

23

002/BR020

Hinge Casting

48*

010/EW51

Ash Carrier (Optional Extra)

24

008/FFW026

M6 Heavy Brass Washer

25

008/FFR003

Hinge Pin

*These items are not shown on the drawing.

# Please specify colour when ordering.

This drawing is for identification purposes only.

33

7

9

8

37

36

34

15

16

13

26

14

4

27

5

6

24

25

17

30

32

40

43

39

41

47

42

45

44

46

35

38

10

11

28

29

31

23

12

19

21

22

18

20

Grate Kit (Optional Extra)

Содержание LA10

Страница 1: ...Operating Installation Instructions charnwood ...

Страница 2: ......

Страница 3: ...Clearing 6 Chimney Sweeping 7 Trouble Shooting 7 CO Alarm 8 If you need further help 8 INSTALLATION INSTRUCTIONS Health Safety Precautions 9 CO Alarms Specification Chimney Hearth Fire Surround Connection to Flues 10 Soot Doors 11 Pre Lighting Check 11 Commissioning 11 Dimensions 12 Parts Lists 13 Certification 14 5 Controlling The Fire 9 9 9 9 Ref LA10 06 13 ISSUE B ...

Страница 4: ...erials ensure that you have good balance before operating the fire Do not use an aerosol spray on or near the stove when it is alight There is a risk of explosion or flash ignition of the spray The stove is suitable for intermittent operation This stove has been designated to burn wood Only dry well seasoned wood should be burnt on this appliance as burning wet unseasoned wood will give rise to he...

Страница 5: ...ed most of the time to control the burning rate and to keep the glass clean Fully extended gives full airwash for faster burning and clean glass whereas fully closed gives low burning It will not be possible to keep the glass clean if this control is fully closed particularly immediately after refuelling When the stove is hot these controls must only be operated using the tool provided or a glove ...

Страница 6: ...ss then open the door and allow it to cool Clean the glass using a damp cloth and then wiping over with a dry cloth Any stubborn deposits on the glass may be removed with a proprietary stove glass cleaner or ceramic hob cleaner Do not use abrasive cleaners or pads as these can scratch the surface which will weaken the glass and cause premature failure the inside of the door and firebox with a ligh...

Страница 7: ...e of fume emission is flueway or chimney blockage For your own safety these must be kept clean CHIMNEY SWEEPING TROUBLE SHOOTING Where the chimney previously served an open fire it is possible that the higher flue gas temperature from a stove may loosen soot deposits with the consequent risk of flue blockage It is therefore recommended that the chimney be swept a second time within a month of regu...

Страница 8: ... should then be cleaned If the chimney fire does not go out when the above action is taken then the fire brigade should be called immediately After a chimney fire the chimney should be carefully examined for any damage Expert advice should be sought if necessary CO ALARM Your installer should have fitted a CO alarm in the same room as the appliance If the alarm sounds unexpectedly follow the instr...

Страница 9: ...ea of vent is 27 5cm 4 3in The vent must be positioned such that it is not liable to blockage SPECIFICATION CHIMNEY HEARTH AND FIRE SURROUND The nominal output of the LA10 is 4 8 kW 16 300 Btu h This output is based on a 45minute re fuelling cycle burning seasoned hardwood logs The average flue temperature at rated output is 266 C The Flue gas mass flow is 4 8g s and the stove weight is 62kg In or...

Страница 10: ...f 460mm 18 inches and preferably 600mm 24 inches from the appliance In some situations it may be necessary to shield the beam or mantelpiece to protect it In order for the fire to operate correctly and to allow for access there must be an air gap behind the appliance of at least 75mm but be aware that this distance will need to be greater in some cases to meet Building Regulation requirements CONN...

Страница 11: ... vertical rear flue connector does allow the chimney to be swept through the stove SOOT DOORS PRE LIGHTING CHECK Soot doors may either be in the actual brickwork of the chimney or in the register plate Various positions of soot doors are shown in Figs 5 to 8 Ensure that the throat plate is fitted in the roof of the appliance The location and positioning of the throat plate is shown in Fig 3 Check ...

Страница 12: ... LA10 DIMENSIONS mm 12 charnwood ...

Страница 13: ...58 Back Fire Plate Inc Gasket 35 004 DY22 Riddler Blanking Disc 11 010 FR008 Fence Assembly 36 012 FR011 Serial No Label 12 002 EY24 Wood Ash Retainer 37 001 FR010 Firebox 13 008 FR017 Air Slide Knob 38 010 EY20 Grate Kit Optional Extra 14 010 FR002 Air Slide 39 002 EY03 Grate Plate 15 002 FR003 Handle Casting 40 010 EY09 Rear Grate Support 16 008 FR012 Wooden Handle 41 010 EY06 Front Grate Suppor...

Страница 14: ...on of CO in combustion products Flue gas temperature Space heating thermal output Energy efficiency Fuel types A Division of A J Wells Sons Limited Registered in England No 03809371 11 Bishops Way Newport Isle of Wight PO30 5WS United Kingdom A J WELLS SONS LTD A J WELLS SONS LTD FR44 CPD 2011 600 mm 700 mm 0 23 266 C 4 8kW 76 9 Wood Logs ...

Страница 15: ......

Страница 16: ... r e d i n E n g l a n d N o 0 3 8 0 9 3 7 1 charnwood T 4 4 0 19 8 3 5 3 7 7 7 7 F 4 4 0 19 8 3 5 3 7 7 8 8 C O N TA C T U S AT W W W C H A R N W O O D C O M BISHOPS WAY NEWPORT ISLE OF WIGHT PO30 5WS UNITED KINGDOM y o u r p re m i e r d e a l e r REV LA10 06 13 ISSUE B ...

Отзывы: