background image

®

charnwood

I S L A N D

II

ct

Issue D

* These items are not shown on the drawing.
## Please specify colour when ordering.

To obtain spare parts please contact your local stockist giving Model,

Part No. and Description. In case of difficulty contact the

manufacturer at the address shown.

This drawing is for identification purposes only.

13

ISLAND IIct PARTS LIST

charnwood

®

charnwood

BISHOPS   WAY,   NEWPORT,   ISLE   OF   WIGHT     PO30   5WS,   UNITED   KINGDOM

T:+ 4 4 (0 )19 8 3 5 377 9 9

F :+ 4 4 (0 )19 8 3 5 377 8 8

SPA RE S@C H A RN WO O D .C O M

WWW.C H A RN WO O D .C O M

I S L A N D

3

4

19

20

32

36

29

37

35

35

40

34

17

33

17

39

15

12

11

43

49

48

44

45

46

46 52

11 12

15

13

14

16

13

13

5

7

6

31

23

21

42

24

26

28

41

25

27

11

38

22

30

8

54

23a

Item

Part No.

Description

1*

008/BY35S

Door Seal Set Inc. Adhesive

2*

008/FW29

Door Seal Adhesive

3

002/CG20

Bottom Grate Bar

4

002/CG20S12

Set of Grate Bars (12)

5

002/CY15

Side Fire Plate

6

002/BY16

Back Fire Plate

7

004/BY24

Ash Shedding Plate

8

006/BY18

Glass (Inc Seal)

9*

008/AY45

Glass Seal

10

004/KV23

Glass Retainer

11

010/BY87/##

Store Stand

12

010/BY12S/##

Set Short Legs

13

011/BY48S

Set of Fire Bricks (4)

14

004/XV30

Brick Retainer

15

010/BY13S/##

Set High Legs

16

010/BY47

Throat Plate

17

008/AY26S

Set of Air Inlet Flap Pads

18

012/BY33

Mover Bar

19

002/BY30

Carrier Bar

20

012/AY13

Idler Rod

21

012/AY15

Riddler Rod

22

004/BY17

Ashpan

23

002/BY07B

Front Firebar

23a

002/BY08

Deepening Bar

24

008/KV16

R.H. Door Handle

25

002/AY14

Door Catch Cam

26

008/KV13

L.H. Door Knob

27

008/BW39/S

Hinge Pin Set

28

002/PY24

Hinge Post

29

008/AY37

Air Control Knob

30

010/AY34

Riddling/Ashpan Tool

31

002/AY27

Riddler Knob

32

004/AY21

Air Bypass Slide

33

004/AY22-1P

Primary Air Inlet Flap

34

004/AY22-1S

Secondary/Bypass Air Inlet Flap

35

004/AY24-02

Flap Mounting Rod (Inc. Fixings)

36

004/BY23-07

Air Control Rod

37

004/AY23

Actuator Assembly

38

008/AY39

Upper Quattro Box Gasket

39

010/AY20

Upper Quattro Box

40

010/AY19

Lower Quattro Box

41

002/BY01

Left Hand Door

42

002/BY02

Right Hand Door

43

001/WS10

Firebox (Island Iict)

44

010/WS22

Lid

45

008/WS40

Lid Handle

46

010/WS13

Top Frame

48

012/WS11

Serial No. Label

49

010/TW33

Vert. Rear Flue Connector (Opt'l Extra)

50*

010/BW51

Ash Carrier (Optional Extra)

51*

010/BY83

Smoke Reducing Kit

52

008/WS36

Soapstone Cooktop

53*

010/AY52A

External Air Manifold Kit

54

004/PY25B

Hinge Post Shim

Item

Part No.

Description

Содержание I S L A N D

Страница 1: ...Operating Installation Instructions charnwood I S L A N D IIct ...

Страница 2: ......

Страница 3: ...weeping Trouble Shooting If you need Further help Health Safety Precautions Specification Chimney Hearth Fire Surround 4 4 4 5 5 5 6 6 6 7 7 7 8 9 9 9 9 INSTALLATION INSTRUCTIONS Lighting Connection to Flues Soot Doors Pre Lighting Check Commissioning Island IIct Dimensions Parts Lists Certification 5 10 10 10 11 12 CO Alarms CAA and Smoke Control 9 11 13 14 I S L A N D IIct Ref Island IIct 06 13 ...

Страница 4: ...od should be cut and split and then left to season in a well ventilated dry place for at least one year but preferably two years before use This stove will not produce significant smoke if well seasoned logs of less than 20 moisture content are burnt and these instructions are adhered to Burning wet 20 moisture content wood and operating the stove in an irresponsible manner may produce smoke which...

Страница 5: ...s then load with logs up to the level of the air holes in the back firebricks Maintain the air control at maximum at this stage Once the fire is up to temperature the airwash system will begin to work so allow the fire to become hot before adjusting the air controls to the required setting During the lighting period do not leave the stove unattended On initial lighting the stove may smoke and give...

Страница 6: ...ring it to rest in the slot provided You are now ready to experience the delights of Charnwood cooking Remember that the soapstone heats up gradually but retains its heat and may well get hotter than you are used to so be vigilant It has natural non stick properties that often improve with use Cleaning Cleaning the Glass then wipe over with a dry cloth Any stubborn deposits on the glass may be rem...

Страница 7: ...n situations where it is not possible to sweep through the appliance the installer will have provided alternative means such as a soot door After sweeping the chimney the appliance flue outlet and the flue pipe connecting the stove to the chimney must be cleaned with a flue brush After clearing any soot from within the stove replace the throat plate see 4 the front firebar Different types of sweep...

Страница 8: ...y installed and operated this appliance will not emit fumes Occasional fume from de ashing and re fuelling may occur Persistent fume emission is potentially dangerous and must not be tolerated If fume emission does persist then the following immediate actions should be taken a Open doors and windows to ventilate the room and then leave then premises b Let the fire go out c Check for flue or chimne...

Страница 9: ...eter or 150 x 150mm internal square CO ALARMS There must be an adequate air supply into the room in which the appliance is installed to provide combustion air The combustion air supply for Island IIct must be via a permanently open vent The minimum free area is 16 5cm 2 5 in 2 2 you find that the chimney is in poor condition then expert advice should be sought regarding the necessity of having the...

Страница 10: ... chimney may be swept through the appliance Horizontal lengths of flue must be kept to a minimum and should not be more than the flue diameter The sealing face of the Flue Collar or Vertical Rear Flue Connector should be sealed with the flat adhesive rope seal provided before fixing to the body of the stove using the two screws provided All flue connections must be well sealed It is possible to pa...

Страница 11: ...authorised fuel for use within a smoke control area unless it is used in an exempt appliance exempted from the controls which generally apply in the smoke control area The Secretary of State for Environment Food and Rural Affairs has powers under the Act to authorise smokeless fuels or exempt appliances for use in smoke control areas in England In Scotland and Wales this power rests with Ministers...

Страница 12: ...P VIEW 605 622 331 Max dim with door open 639 Optional Vertical Rear Flue Adapter 421 476 88 564 668 632 9 9 99 155 365 447 Optional External Air Manifold 87 610 759 870 584 447 190 401 48 179 701 301 295 289 451 120 811 Flue outlet to suit 150mm 6 flue pipe ISLAND II DIMENSIONS ct 632 632 263 IIct Cooking Area 490 x 240mm ...

Страница 13: ... Set of Fire Bricks 4 14 004 XV30 Brick Retainer 15 010 BY13S Set High Legs 16 010 BY47 Throat Plate 17 008 AY26S Set of Air Inlet Flap Pads 18 012 BY33 Mover Bar 19 002 BY30 Carrier Bar 20 012 AY13 Idler Rod 21 012 AY15 Riddler Rod 22 004 BY17 Ashpan 23 002 BY07B Front Firebar 23a 002 BY08 Deepening Bar 24 008 KV16 R H Door Handle 25 002 AY14 Door Catch Cam 26 008 KV13 L H Door Knob 27 008 BW39 S...

Страница 14: ...5WS United Kingdom A J WELLS SONS LTD A J WELLS SONS LTD Roomheater Model Island IIct EC Certificate of conformity no WS080 CPD 2012 Fuel type WOOD LOGS Emission of CO in combustion products 0 15 Mean flue gas temperature 307 C Space heating Thermal output 8 0kW Energy efficiency 79 0 Minimum distance to combustible materials Side Rear 600mm 700mm ISLAND IIct ...

Страница 15: ......

Страница 16: ...e d i n E n g l a n d N o 0 3 8 0 9 3 71 charnwood BISHOPS WAY NEWPORT ISLE OF WIGHT PO30 5WS UNITED KINGDOM T 4 4 0 19 8 3 5 3 7 7 7 7 F 4 4 0 19 8 3 5 3 7 7 8 8 C O N TA C T U S AT W W W C H A R N W O O D C O M y o u r p re m i e r d e a l e r Ref Island IIct 06 13 Issue D ...