CONNECTIONS TO FLUES
The stove must be connected to the flue using flue pipe of the
following sizes:
If the optional vertical rear flue connector is used then the chimney
may be swept through the appliance.
Horizontal lengths of flue must be kept to a minimum and should not
be more in length than the flue diameter.
The stove comes with the blanking plate fitted to the top flue outlet.
The seal for the
outlet is a 180mm dia ring of rope seal. The seal
for the
outlet is a length of adhesive backed fibre webbing
supplied with instructions. This is applied to the flue collar or the
Vertical Rear Flue adapter for rear outlet installations. For top outlet
installations, the blanking plate must be removed, have the webbing
fitted to its sealing face, and fitted to the rear flue outlet.
Stove Model C-Four & C-Five.....................125mm (5") i/d pipe.
Stove Model C-Six, C-Seven & C-Eight........150mm (6") i/d pipe.
top
rear
This may be stainless steel, cast iron, or thick wall steel pipe. Straight
lengths of Charnwood Pipe to match the stove are available if
required.
There are several ways of connecting the stove to the flue. These are
illustrated in Figs. 4 to 7.
Ensure that
the fold on the clamping plate is in line with the lugs on the firebox as
shown in Fig 8. Ensure that the clamping plate does not prevent the
throat plate from seating correctly. All flue connections must be well
sealed.
For top outlet installations on the
the flue collar
deflector must be fitted at the same time as the flue collar because it
uses the same bolts to secure it to the stove. The longest length of the
flue collar deflector must be aligned with the front of the stove as
shown in Fig 9.
C Five, Six & Seven
SOOT DOORS
It is possible to pass a 16 inch diameter sweeps brush through the
appliance but in most back outlet installations it will be necessary to
have a soot door to enable the chimney to be swept. The optional
vertical rear flue connector does allow the chimney to be swept
through the stove. Soot doors may either be in the actual brickwork
of the chimney or in the register plate. Various positions of soot
doors are shown in Figs. 4 to 7.
UNPACKING THE STOVE
The stove arrives bolted and shrink-wrapped to its pallet. There must
be adequate facilities for unloading and manoeuvring into position
The wrapping is first removed, then the stove released from the pallet
by either removing the single bolt (C-4) or 4 pallet bolts(C-5 to C-8)
11
®
INSTALLATION INSTRUCTIONS
Register Plate
With Soot Door
Alternative
Soot Door Positions
Fig. 7. Horizontal Register Plate With Optional
Vertical Rear Flue Connector
Fig. 8. Flue Blanking Plate.
Blanking Plate
Clamping plate finishes
flush with inside face of
firebox top and bottom.
with Glass Fibre Webbing
Seal Blanking Plate
Glass Fibre Webbing
Blanking Plate
Back of Stove
Clamping Plate
M8 Nut
Flue Collar
Rope seal
Flue Collar
Front of Stove
Deflector
Fig. 9. Flue Collar Deflector fitting.
Содержание C-Five
Страница 1: ...Operating Installation Instructions charnwood C SERIES ...
Страница 2: ......