background image

Operating & Installation Instructions

charnwood

®

C-SERIES

Содержание C-Five

Страница 1: ...Operating Installation Instructions charnwood C SERIES ...

Страница 2: ......

Страница 3: ...ons CO Alarms Specification Chimney Hearth Fire Surround Connection to Flues Soot Doors Unpacking The Stove Pre Lighting Check Commissioning Clean Air Act Information C FOUR Dimensions Parts Lists 4 4 5 5 5 6 6 6 6 7 8 8 9 10 11 11 11 12 12 12 14 15 19 5 9 9 9 13 16 17 18 20 21 22 23 Controlling The Fire Certification C FIVE Dimensions C SIX Dimensions C SEVEN Dimensions C EIGHT Dimensions C FOUR ...

Страница 4: ...using the stove FUEL Before lighting the stove check with the installer that the work and checks described in the Installation Instructions have been carried out correctly and that the chimney has been swept is sound and free from any obstructions The stove is not suitable for use in a shared flue system Remember that the stove will be hot and that it is made from hard materials ensure that you ha...

Страница 5: ...cessive smoke production For high output move the air control to the click position or for low burning to the fully closed position When the fire is burning normally the air control gives enough airwash to keep the glass clean However it will not always be possible to keep the glass clean with the air control fully closed Keep the firebox well filled but do not allow fuel to spill over the top of ...

Страница 6: ...sits on the glass may be removed with a proprietary stove glass cleaner or ceramic hob cleaner Do not use abrasive cleaners or pads as these can scratch the surface which will weaken the glass and cause premature failure After long periods where the fire has been out of use the chimney and appliance flueways should be cleaned before lighting Door Seals Servicing For the fire to operate correctly i...

Страница 7: ...rol Chimney Fires month of regular use after installation The chimney should be swept at least twice a year Where the top outlet or vertical rear flue connector is used it will generally be possible to sweep the chimney through the appliance First remove the fuel retainer and the throat plate Then sweep the chimney ensuring that soot is removed from all horizontal surfaces after sweeping In situat...

Страница 8: ...advice should be sought if necessary Your installer should have fitted a CO alarm in the same room as the appliance If the alarm sounds unexpectedly follow the instructions given under Warning Note above If you need further help with your Charnwood then your Installer will be able to provide the answers to most questions Your Local Charnwood Premier Dealer has a great deal of experience and will a...

Страница 9: ...house In older properties the air permeability will be above 5 0m h m but in some modern properties it may be less 3 2 The vent must be positioned such that it is not liable to blockage SPECIFICATION CHIMNEY The outputs in the table are based on a 45 minute re fuelling cycle burning seasoned hardwood logs All tests are carried out in accordance with BSEN 13240 In order for the appliance to perform...

Страница 10: ... in front of the stove by at least 300mm 12 in and to the sides of the stove by at least 150mm 6 in If in doubt as to the positioning of the stove expert advice should be sought either from the supplier or the local building inspector The fireplace must allow good circulation of air around the appliance to ensure that maximum heat is transferred to the room and also to prevent the fireplace from o...

Страница 11: ...be well sealed For top outlet installations on the the flue collar deflector must be fitted at the same time as the flue collar because it uses the same bolts to secure it to the stove The longest length of the flue collar deflector must be aligned with the front of the stove as shown in Fig 9 C Five Six Seven SOOT DOORS It is possible to pass a 16 inch diameter sweeps brush through the appliance ...

Страница 12: ...nated smoke control area It is also an offence to acquire an unauthorised fuel for use within a smoke control area unless it is used in an exempt appliance exempted from the controls which generally apply in the smoke control area The Secretary of State for Environment Food and Rural Affairs has powers under the Act to authorise smokeless fuels or exempt appliances for use in smoke control areas i...

Страница 13: ...LOGS WOOD LOGS WOOD LOGS WOOD LOGS WOOD LOGS Emission of CO in combustion products 0 18 0 19 0 25 0 14 0 15 Mean flue gas temperature 281 C 259 C 272 C 280 C 316 C Space heating thermal output 4 9kW 5 0kW 6 7kW 7 6kW 8 3kW Energy efficiency 78 3 75 7 81 9 76 9 78 0 Minimum distance to combustible materials Side Rear With heat shield and HT insulated flue connector 25mm insulation Side Rear 600mm 6...

Страница 14: ...262 613 560 416 386 84 144 267 373 82 405 114 154 131 45 458 61 ID 64 OD 763 710 416 386 195 608 Optional Vertical Rear Flue Adapter Store Stand Standard Model Front Side Rear Plan View 150 150 140 i d to suit 125mm 5 flue pipe ...

Страница 15: ...mm Store Stand Standard Model Front Side Rear Plan View 15 455 485 560 611 144 292 398 153 82 130 430 114 76 79 65 458 485 455 745 796 185 292 250 643 Optional Vertical Rear Flue Adapter 140 i d to suit 125mm 5 flue pipe ...

Страница 16: ... 63 79 To suit 80mm ducting 161 292 441 615 411 670 119 398 169 131 88 441 146 292 800 855 411 441 185 690 Optional Vertical Rear Flue Adapter Plan View Front Side Rear Store Stand Standard Model 156 i d to suit 150mm 6 flue pipe ...

Страница 17: ...ONS mm 17 800 855 529 185 564 292 690 244 292 160 615 534 564 670 398 169 130 146 440 85 505 59 79 OD 76 Store Stand Standard Model Front Side Rear 156 i d to suit 150mm 6 flue pipe Optional Vertical Rear Flue Adapter ...

Страница 18: ...IONS mm Optional Vertical Rear Flue Adapter 500 710 764 465 292 163 0 76 79 61 605 185 470 895 949 500 292 246 790 169 133 146 88 398 443 Front Side Rear Store Stand Standard Model 18 156 i d to suit 150mm 6 flue pipe ...

Страница 19: ... Disk 42 010 EY12 Serial number hanger bracket 43 010 PV33 Vert Rear Flue Adaptor 44 002 PV12B Flue collar 45 012 PV09 Blanking plate 46 002 BR020 Hinge 47 012 BV20 Ashpan tool 48 004 BR033 Ashpan 49 002 EY03 Grate Plate 50 010 EY04 L H Grate Support 51 010 EY05 R H Grate Support 52 010 EY06 Front Grate Support 53 010 BR035 Rear Grate Support 54 010 EY13 Riddler Rod assy 55 008 PV55 Glass Seal 56 ...

Страница 20: ...ng Plate 46 002 BR020 Hinge casting 47 012 BV20 A Ashpan Door Opening Tool 48 004 BR033 Ashpan 49 002 EY03 Grate Plate 50 010 NR043 L H Grate Support 51 010 NR042 R H Grate Support 52 010 EY06 Front Grate Support 53 010 NR061 Rear Grate Support 54 010 DR060 Riddler Rod assy 55 008 NR044 Glass Seal 56 008 FW29 Door Seal Adhesive 57 002 BR012 Handle arm 58 004 BR015 Clicker Retainer Plate 59 008 ES3...

Страница 21: ...er 38 008 CR026 Side Gasket 39 008 CRO48 Air Inlet Spigot assy 40 004 CR064 Blanking plate 41 004 DY22 Riddler Blanking Disk 42 010 EY12 Serial number hanger bracket 43 010 TW33 Vert Rear Flue Adaptor 44 002 CH12B Flue collar 45 012 TW09 Blanking plate 46 002 BR020 Hinge 47 012 BV20 A Ashpan tool 48 004 BR033 Ashpan 49 002 EY03 Grate Plate 50 010 CR043 L H Grate Support 51 010 CR042 R H Grate Supp...

Страница 22: ...0 A Ashpan Door Opening Tool 48 004 ER033 Ashpan 49 002 EY03 Grate Plate 50 010 ER043 L H Grate Support 51 010 ER042 R H Grate Support 52 010 ER065 Front Grate Support 53 010 ER061 Rear Grate Support 54 010 ER060 Riddler Rod assy 55 008 ER044 Glass Seal 56 008 FW29 Door Seal Adhesive 57 002 BR012 Handle arm 58 004 BR015 Clicker Retainer Plate 59 008 ES36 Brass ball catch 60 010 ER022 Grate Kit Inc...

Страница 23: ...BR052 Felt washer 38 011 DR038 Side Gasket 39 004 CR048 Air Inlet Spigot assy 40 004 CR064 Blanking plate 41 004 DY22 Riddler Blanking Disk 42 010 EY12 Serial number hanger bracket 43 010 TW33 Vert Rear Flue Adaptor 44 002 PV12B Flue collar 45 012 TW09 Blanking plate 46 002 BR020 Hinge 47 012 BV20 A Ashpan tool 48 004 BR033 Ashpan 49 002 EY03 Grate Plate 50 010 DR043 L H Grate Support 51 010 DR042...

Страница 24: ...e r e d i n E n g l a n d N o 0 3 8 0 9 3 7 1 charnwood BISHOPS WAY NEWPORT ISLE OF WIGHT PO30 5WS UNITED KINGDOM T 4 4 0 19 8 3 5 3 7 7 7 7 F 4 4 0 19 8 3 5 3 7 7 8 8 C O N TA C T U S AT W W W C H A R N W O O D C O M y o u r p re m i e r d e a l e r REV C Series v3 04 13 ...