12
®
INSTALLATION INSTRUCTIONS
1. ATTACH FLUE COLLAR TO THE FLUE PIPE
It is recommended to use a flue liner with a length of flexible flue
pipe. Fix the upper flue collar to the flue pipe through the screw
holes in the side of the ring. The flue collar can be attached at any
angle depending on the required angle of the flue.
It is vital that the connections at both ends of the flue pipe are well
sealed. The flue pipe and collar can be sealed with fire cement and/or
a gasket. A closure plate should be used at the top end of the flue
pipe.
Once the collar is attached, push the flue pipe and flue collar up out
of the way for the casing to be inserted.
2. INSERT THE CONVECTION CASING INTO THE OPENING
Make sure the three self-clinching studs are in the holes in the flue
collar, pointing downwards. Slide the convection casing into position
in the opening until the flue outlet lines up with the flue pipe.
Line up studs with holes
in convection casing
FITTING THE CONVECTION CASING,
STOVE AND FLUE PIPE
It is recommended to have a layer of insulation between the casing
and the outer wall. This may consist of a layer of mineral fibre or a
vermiculite concrete mix (see Step 4). If rockwool is being used,
insert this into the opening before sliding in the convection casing.
Upper flue collar
Convection casing
3. MAKE FLUE CONNECTION
Reaching through the flue outlet, pull the flue collar down through
the outlet until the studs line up with the four holes in the convection
casing. Use nuts to secure the studs into place.
Convection casing
External air supply
1. Attach flue collar to length of flexible flue liner
2. Insert convection casing into opening
Upper flue collar
Flexible flue liner
Self-clinching studs
Fix collar to flue with
screws either side
Collar can be positioned as necessary
depending on required angle of flue
Flue pipe
Sealed with gasket
Secure stud with nut
charnwood