Congratulations on becoming the owner of a Charnwood Aire 5 
Stove. Your stove has been approved in smoke control areas to burn 
wood logs if it is used in accordance with these instructions. It is very 
important that you read and understand these instructions before 
using the stove. 

Before lighting the stove check with the installer that the work and 
checks described in the Installation Instructions have been carried 
out correctly and that the chimney has been swept, is sound and free 
from any obstructions. The stove is not suitable for use in a shared 
flue system.

If you are using your stove to burn wood logs in a smoke controlled 
area, then the provided Defra Stop 

MUST

 be fitted and the 

instructions on lighting and refuelling 

MUST

 be followed. This stove 

will not produce significant smoke if well seasoned logs of less than 
20% moisture content are burnt and these instructions are adhered 
to. Burning wet (>20% moisture content) wood and operating the 
stove in an irresponsible manner may produce smoke which is illegal 
in smoke controlled areas.

Remember that the stove will be hot and that it is made from hard 
materials – ensure that you have good balance before operating the 
fire. Always use the provided operating tool and gloves.

Do not use an aerosol spray on or near the stove when it is alight. 
There is a risk of explosion or flash ignition of the spray.

When using the stove in situations where children, aged and/or infirm 
persons are present a fireguard must be used to prevent accidental 
contact with the stove. The fireguard should be manufactured in 
accordance with BS 8423:2002. 

The stove is suitable for intermittent operation.

FUEL

This stove has been designated to burn wood. Only dry well 
seasoned wood should be burnt on this appliance as burning wet 
unseasoned wood will give rise to heavy tar deposits in the stove, on 
the glass and within the chimney. For the same reason hard woods 
(such as Ash, Beech and Oak) are better than soft woods (such as 
Pine and Spruce). Burning wet unseasoned wood will also result in 
considerably reduced outputs. The wood should be cut and split and 
then left to season in a well ventilated dry place for at least one year 
but preferably two years before use.

Approximate suitable log sizes are:

300mm(11in) long and 75mm (3in) diameter

Log moisture content of less than 20% is recommended.

PETROLEUM COKE IS NOT SUITABLE FOR USE ON THIS 
APPLIANCE. ITS USE WILL INVALIDATE THE GUARANTEE.

This stove is not designed to burn household waste.

LIGHTING

On initial lighting, the stove may smoke and give off an odour as the 
silicon paint with which the firebox is painted reacts to the heat. This 
is normal and will cease after a short time, but meanwhile the room 
should be kept well ventilated.

At first only light a small fire and burn it slowly for two hours to allow 
any residual moisture in the chimney to evaporate.

Light the stove using dry kindling wood and paper or fire lighters. 
Put the paper, or fire lighters, and kindling in the firebox and cover 
with a few small dry logs. Open the air controls – the primary air 
control in the door and the airwash control - fully (see Fig. 1) Light 
the paper or fire lighters. The door may be left cracked open for a 
few minutes to assist the combustion and heat up the firebox more 
quickly. When the kindling wood is well alight add a few more small 
logs, close the door but leave the air control fully open. When the 
flames are established around these logs, load the stove with the 
required fuel load. Maintain the air control at maximum at this stage. 
Once the fire is up to temperature the airwash system will begin to 
work, so allow the fire to become hot before adjusting the air control 
to the required setting. During the lighting period, do not leave the 
stove unattended. Do not leave the door open except as directed 
above to avoid excessive smoke.

When relighting the stove, leave the ash on the base, unless it is 
becoming too deep, in which case some of it may be removed.

CONTROLLING THE FIRE

The rate of burning and hence the output is controlled by the air 
control (see Fig.1)

Open the air control fully (boost position) when lighting or when 
rapid burning is required. It should not be left fully open for long 
periods as this can cause over-firing or excessive smoke production. 
For high output move the air control to the ‘click position’ or for low 

Содержание Aire 5 low

Страница 1: ... Operating Installation Instructions ...

Страница 2: ......

Страница 3: ...EPING 7 TROUBLE SHOOTING 8 CO ALARM 8 IF YOU NEED FURTHER HELP 8 UNPACKING THE STOVE 9 HEALTH AND SAFETY PRECAUTIONS 9 CO ALARMS 9 SPECIFICATION 9 INSTALLATION INSTRUCTIONS 9 CHIMNEY 10 HEARTH AND FIRE SURROUND 10 CONNECTIONS TO FLUES 10 SOOT DOORS 11 PRE LIGHTING CHECK 11 COMMISSIONING 11 DIMENSIONS 13 AIRE 5 STORE STAND PARTS LIST 14 AIRE 5 LOW PARTS LIST 15 CERTIFICATION 16 Ref aire5 v1 08 19 ...

Страница 4: ...ty deposits into fire CHIMNEY Have chimney swept twice a year Chimney can be swept through stove SERVICING Stove should be serviced by a professional at least once a year Suitable fuels for your Charnwood Wood logs Unsuitable fuels Petroleum coke Liquid fuel Household waste Coal singles Small nuts or coal dust Wet or unseasoned wood Smokeless mineral fuel LIGHTING AND CONTROLLING THE FIRE Add kind...

Страница 5: ...ed outputs The wood should be cut and split and then left to season in a well ventilated dry place for at least one year but preferably two years before use Approximate suitable log sizes are 300mm 11in long and 75mm 3in diameter Log moisture content of less than 20 is recommended PETROLEUM COKE IS NOT SUITABLE FOR USE ON THIS APPLIANCE ITS USE WILL INVALIDATE THE GUARANTEE This stove is not desig...

Страница 6: ...instructions as this can cause excessive smoke ASH CLEARANCE For optimum wood burning it is important to leave a layer of ash around 1cm thick on the base of the ashpan Before removing ash ensure that it has cooled down The ashpan slides out for easy ash removal To make ash removal easier there are ash carriers available These may be purchased from your supplier or in case of difficulty from Charn...

Страница 7: ... then be swept from the throat plate and into the fire To return the lower throat plate to its correct position At an angle insert the throat plate so that it sits on top of either the right or left side of the retaining flange on the side plates Raise the opposite side of the throat plate and slide so that the throat plate is central and supported by both side plates Slide back so that the throat...

Страница 8: ...arning Note Properly installed and operated this appliance will not emit fumes Occasional fumes from de ashing and re fuelling may occur Persistent fume emission is potentially dangerous and must not be tolerated If fume emission does persist then the following immediate actions should be taken a Open doors and windows to ventilate the room and then leave the premises b Let the fire out and safely...

Страница 9: ... may be less The vent must be positioned such that it is not liable to blockage Minimium areas are given in the following table A fixed ducted air supply may be used as an alternative to the traditional method of using a permanent open vent into a room to supply air for combustion External air supply kits are available please contact Charnwood for more information Instruction sheet ref TIS 120 Thi...

Страница 10: ...regulations The hearth must be of fireproof material and at least 12mm 1 2in thick The positioning of the stove and the size of the hearth are governed by building regulations for Class 1 appliances These building regulations state that the hearth must extend in front of the stove by at least 225mm 9 in and to the sides of the stove by at least 150mm 6 in When the fire door is open it extends beyo...

Страница 11: ...ough the stove Soot doors may either be in the actual brickwork of the chimney or in the register plate Various positions of soot doors are shown in Figs 5 to 8 PRE LIGHTING CHECK Ensure that the throat plate and upper baffle is fitted in the roof of the appliance For location and positioning see Fig 2 Check that the front fence is fitted correctly and that the door closes properly COMMISSIONING O...

Страница 12: ...Agriculture Environment and Rural Affairs under Section 16 of the Environmental Better regulation Act Northern Ireland 2016 In Wales appliances are exempted by regulations made by Welsh Ministers Further information on the requirements of the Clean Air Act can be found here https www gov uk smoke control area rules Your local authority is responsible for implementing the Clean Air Act 1993 includi...

Страница 13: ...3 DIMENSIONS FRONT SIDE REAR PLAN VIEW To suit 150mm 6 flue pipe VERTICAL REAR FLUE ADAPTOR WITH HEATSHIELD 178 424 246 463 96 600 470 129 618 755 470 129 774 424 79 645 232 79 489 76 STORE STAND LOW 400 ...

Страница 14: ... 004 BR021 Hinge Shim 15 002 BR020 Hinge 16 008 ST068 2 Hinge Pin Set 17 002 AB001 Door Assembly 18 008 FFW027 M10 Wavy Washer 19 004 AB059 Handle Spacer 20 002 AB012 Handle Boss 21 008 FFP015 M4 x 12 Spring Pin 22 008 FFS093 M8 x 30 Socket Head Screw 23 008 AB026 Door Handle 24 008 FFS086 M4 x 8 Plasfix Screw 25 008 FFM083 Flanged Bearing 26 008 AB110 Air Control Gasket 27 010 AB130 Air Control P...

Страница 15: ... 13 002 CH12B Flue Collar 14 004 BR021 Hinge Shim 15 002 BR020 Hinge 16 008 ST068 2 Hinge Pin Set 17 002 AB001 Door Assembly 18 008 FFW027 M10 Wavy Washer 19 004 AB059 Handle Spacer 20 002 AB012 Handle Boss 21 008 FFP015 M4 x 12 Rollpin 22 008 FFS093 M8 x 30 Socket Head Screw 23 008 AB026 Door Handle 24 008 FFS086 M4 x 8 Plasfix Screw 25 008 FFM083 Flanged Bearing 26 008 AB110 Air Control Gasket 2...

Страница 16: ...2019 ABL11 CPD 2019 Fuel type WOOD LOGS WOOD LOGS Rated space heating thermal output 5kW 5kW Emission of CO in combustion products 0 09 0 09 Mean flue gas temperature 230 230 Energy efficiency 84 84 Particles mg m3 n 27 27 Minimum distance to combustible materials Side Rear with single walll flue Rear with insulated flue heatshield 350 350 100 350 350 100 Fulfilled requirements BStV of the City of...

Страница 17: ... 5 0 5 0 6 7 5 9 8 0 5 0 6 2 12 0 5 0 8 0 5 0 7 3 4 9 5 0 7 6 7 1 8 3 12 3 4 8 8 6 4 1 4 3 8 3 8 0 8 3 12 3 5 0 8 0 8 0 8 4 12 3 11 0 4 8 5 8 8 4 5 2 ENERGY EFFICIENCY INDEX INDICE DE EFICIENCIA ENERGÈTICA INDICE DI EFFICIENZA ENERGETICA WSKAŹNIK EFEKTYWNOŚCI ENERGETYCZNEJ 112 8 109 9 108 5 108 5 108 5 108 5 109 9 109 9 107 0 109 9 109 8 109 9 108 5 112 8 107 7 107 0 114 3 109 9 115 7 107 0 104 5 ...

Страница 18: ......

Страница 19: ......

Страница 20: ...your premier dealer ...

Отзывы: