INSTALLATION INSTRUCTIONS

CHIMNEY

In order for the appliance to perform satisfactorily the chimney 
height must not be less than 4 metres measured vertically from the 
outlet of the stove to the top of the chimney. The internal dimensions 
of the chimney should preferably be 150-200 mm (6”- 8”) either 
square or round and MUST NOT BE LESS THAN 150 mm (6”)

If an existing chimney is to be used it must be swept and checked, 
it must be in good condition, free from cracks and blockages, and 
should not have an excessive cross sectional area. If it was previously 
used by an open fire then the chimney should be swept one month 
after installation to clear any soot falls which may have occurred due 
to the difference in combustion between the stove and the open fire. 
If you find that the chimney is in poor condition then expert advice 
should be sought regarding the necessity of having the chimney lined. 
If it is found necessary to line the chimney then a lining suitable for 
Solid Fuel must be used.

If there is no existing chimney then a prefabricated block chimney 
or a twin walled insulated stainless steel flue to BSEN 15287-1:2007 
can be used either internally or externally. These chimneys must be 
fitted in accordance with the manufacturers instructions and Building 
Regulations.

Single wall flue pipe is suitable for connecting the stove to the chimney 
but is not suitable for using for the complete chimney. If it is found 
that there is excessive draw in the chimney then a draught stabiliser 
should be fitted.

It is important that there is sufficient draw in the chimney and that the 
chimney does not suffer from down-draught. When the chimney is 
warm the draw should be not less than 1.25mm (0.05”) water gauge 
(12 Pa). If in doubt about the chimney seek expert advice.

HEARTH AND FIRE SURROUND

The stove must stand on a fireproof hearth and must not be situated 
closer than the minimum distance from combustible materials (see 
specification table) to the sides or rear above hearth level unless 
adequately fireproofed in accordance with local building regulations. 
The hearth must be of fireproof material and at least 12mm (1/2in.) 
thick. The positioning of the stove and the size of the hearth are 
governed by building regulations for Class 1 appliances. These 
building regulations state that the hearth must extend in front of the 
stove by at least 225mm (9 in.) and to the sides of the stove by at 
least 150mm (6 in.). When the fire door is open, it extends beyond 
the flat front of the stove by 430mm.

If in doubt as to the positioning of the stove, expert advice should be 
sought either from the supplier or the local building inspector. The 
fireplace must allow good circulation of air around the appliance to 
ensure that maximum heat is transferred to the room and also to 
prevent the fireplace from overheating. A gap of 150mm (6”) each 
side and 300mm (12”) above the appliance should give sufficient air 
circulation. If a wooden mantelpiece or beam is used in the fireplace 
it should be a minimum of 460mm (18”), and preferably 600mm 
(24”) from the appliance. In some situations it may be necessary to 
shield the beam or mantelpiece to protect it.

In order for the fire to operate correctly and to allow for access, 
there must be an air gap behind the appliance of at least 50mm, but 
be aware that this distance will need to be greater in some cases to 
meet Building Regulation requirements.

The appliance should be installed on a floor with adequate load-
bearing capacity. If an existing construction does not meet this 
requirement then please take suitable measures to achieve this. (e.g. 
load distributing plate.)

CONNECTIONS TO FLUES

The stove must be connected to the flue using flue pipe of 150mm 
(6”) diameter.

This may be stainless steel, cast iron, or thick wall steel pipe. 
Charnwood Pipe to match the stove is available if required. 

The flue spigot can be shieled with starter length flue see fig. 3

Fig. 3 Shielding the flue spigot

There are several ways of connecting the stove to the flue. These are 
illustrated in Figs. 5 to 8.

If the top flue connection or optional vertical rear flue connector is 
used then the chimney may be swept through the appliance. 

Horizontal lengths of flue must be kept to a minimum and should not 
be more in length than the flue diameter.

Flue spigot

Starter length over flue spigot

Top of stove

Содержание Aire 5 low

Страница 1: ... Operating Installation Instructions ...

Страница 2: ......

Страница 3: ...EPING 7 TROUBLE SHOOTING 8 CO ALARM 8 IF YOU NEED FURTHER HELP 8 UNPACKING THE STOVE 9 HEALTH AND SAFETY PRECAUTIONS 9 CO ALARMS 9 SPECIFICATION 9 INSTALLATION INSTRUCTIONS 9 CHIMNEY 10 HEARTH AND FIRE SURROUND 10 CONNECTIONS TO FLUES 10 SOOT DOORS 11 PRE LIGHTING CHECK 11 COMMISSIONING 11 DIMENSIONS 13 AIRE 5 STORE STAND PARTS LIST 14 AIRE 5 LOW PARTS LIST 15 CERTIFICATION 16 Ref aire5 v1 08 19 ...

Страница 4: ...ty deposits into fire CHIMNEY Have chimney swept twice a year Chimney can be swept through stove SERVICING Stove should be serviced by a professional at least once a year Suitable fuels for your Charnwood Wood logs Unsuitable fuels Petroleum coke Liquid fuel Household waste Coal singles Small nuts or coal dust Wet or unseasoned wood Smokeless mineral fuel LIGHTING AND CONTROLLING THE FIRE Add kind...

Страница 5: ...ed outputs The wood should be cut and split and then left to season in a well ventilated dry place for at least one year but preferably two years before use Approximate suitable log sizes are 300mm 11in long and 75mm 3in diameter Log moisture content of less than 20 is recommended PETROLEUM COKE IS NOT SUITABLE FOR USE ON THIS APPLIANCE ITS USE WILL INVALIDATE THE GUARANTEE This stove is not desig...

Страница 6: ...instructions as this can cause excessive smoke ASH CLEARANCE For optimum wood burning it is important to leave a layer of ash around 1cm thick on the base of the ashpan Before removing ash ensure that it has cooled down The ashpan slides out for easy ash removal To make ash removal easier there are ash carriers available These may be purchased from your supplier or in case of difficulty from Charn...

Страница 7: ... then be swept from the throat plate and into the fire To return the lower throat plate to its correct position At an angle insert the throat plate so that it sits on top of either the right or left side of the retaining flange on the side plates Raise the opposite side of the throat plate and slide so that the throat plate is central and supported by both side plates Slide back so that the throat...

Страница 8: ...arning Note Properly installed and operated this appliance will not emit fumes Occasional fumes from de ashing and re fuelling may occur Persistent fume emission is potentially dangerous and must not be tolerated If fume emission does persist then the following immediate actions should be taken a Open doors and windows to ventilate the room and then leave the premises b Let the fire out and safely...

Страница 9: ... may be less The vent must be positioned such that it is not liable to blockage Minimium areas are given in the following table A fixed ducted air supply may be used as an alternative to the traditional method of using a permanent open vent into a room to supply air for combustion External air supply kits are available please contact Charnwood for more information Instruction sheet ref TIS 120 Thi...

Страница 10: ...regulations The hearth must be of fireproof material and at least 12mm 1 2in thick The positioning of the stove and the size of the hearth are governed by building regulations for Class 1 appliances These building regulations state that the hearth must extend in front of the stove by at least 225mm 9 in and to the sides of the stove by at least 150mm 6 in When the fire door is open it extends beyo...

Страница 11: ...ough the stove Soot doors may either be in the actual brickwork of the chimney or in the register plate Various positions of soot doors are shown in Figs 5 to 8 PRE LIGHTING CHECK Ensure that the throat plate and upper baffle is fitted in the roof of the appliance For location and positioning see Fig 2 Check that the front fence is fitted correctly and that the door closes properly COMMISSIONING O...

Страница 12: ...Agriculture Environment and Rural Affairs under Section 16 of the Environmental Better regulation Act Northern Ireland 2016 In Wales appliances are exempted by regulations made by Welsh Ministers Further information on the requirements of the Clean Air Act can be found here https www gov uk smoke control area rules Your local authority is responsible for implementing the Clean Air Act 1993 includi...

Страница 13: ...3 DIMENSIONS FRONT SIDE REAR PLAN VIEW To suit 150mm 6 flue pipe VERTICAL REAR FLUE ADAPTOR WITH HEATSHIELD 178 424 246 463 96 600 470 129 618 755 470 129 774 424 79 645 232 79 489 76 STORE STAND LOW 400 ...

Страница 14: ... 004 BR021 Hinge Shim 15 002 BR020 Hinge 16 008 ST068 2 Hinge Pin Set 17 002 AB001 Door Assembly 18 008 FFW027 M10 Wavy Washer 19 004 AB059 Handle Spacer 20 002 AB012 Handle Boss 21 008 FFP015 M4 x 12 Spring Pin 22 008 FFS093 M8 x 30 Socket Head Screw 23 008 AB026 Door Handle 24 008 FFS086 M4 x 8 Plasfix Screw 25 008 FFM083 Flanged Bearing 26 008 AB110 Air Control Gasket 27 010 AB130 Air Control P...

Страница 15: ... 13 002 CH12B Flue Collar 14 004 BR021 Hinge Shim 15 002 BR020 Hinge 16 008 ST068 2 Hinge Pin Set 17 002 AB001 Door Assembly 18 008 FFW027 M10 Wavy Washer 19 004 AB059 Handle Spacer 20 002 AB012 Handle Boss 21 008 FFP015 M4 x 12 Rollpin 22 008 FFS093 M8 x 30 Socket Head Screw 23 008 AB026 Door Handle 24 008 FFS086 M4 x 8 Plasfix Screw 25 008 FFM083 Flanged Bearing 26 008 AB110 Air Control Gasket 2...

Страница 16: ...2019 ABL11 CPD 2019 Fuel type WOOD LOGS WOOD LOGS Rated space heating thermal output 5kW 5kW Emission of CO in combustion products 0 09 0 09 Mean flue gas temperature 230 230 Energy efficiency 84 84 Particles mg m3 n 27 27 Minimum distance to combustible materials Side Rear with single walll flue Rear with insulated flue heatshield 350 350 100 350 350 100 Fulfilled requirements BStV of the City of...

Страница 17: ... 5 0 5 0 6 7 5 9 8 0 5 0 6 2 12 0 5 0 8 0 5 0 7 3 4 9 5 0 7 6 7 1 8 3 12 3 4 8 8 6 4 1 4 3 8 3 8 0 8 3 12 3 5 0 8 0 8 0 8 4 12 3 11 0 4 8 5 8 8 4 5 2 ENERGY EFFICIENCY INDEX INDICE DE EFICIENCIA ENERGÈTICA INDICE DI EFFICIENZA ENERGETICA WSKAŹNIK EFEKTYWNOŚCI ENERGETYCZNEJ 112 8 109 9 108 5 108 5 108 5 108 5 109 9 109 9 107 0 109 9 109 8 109 9 108 5 112 8 107 7 107 0 114 3 109 9 115 7 107 0 104 5 ...

Страница 18: ......

Страница 19: ......

Страница 20: ...your premier dealer ...

Отзывы: