THERMOSTAT MODEL
HOW
MP-R
MP-A
MP-N
MP-SW
MP-F
MP-T
MP-TM
T ri
±3.0°C
(0°C)
±3.0°C
(0°C)
±3.0°C
(0°C)
±3.0°C
(0°C)
±3.0°C
(0°C)
±3.0°C
(0°C)
±3.0°C
(0°C)
Offset
While OFF press keep pressed
until word “tri”
appear. Adjust the value by pressing up and down
arrows. Leave the device to return to normal
operation.
dt
-0.1°C…-1.0°C
(0.6°C)
-0.1°C…-1.0°C
(0.6°C)
-0.1°C…-1.0°C
(0.6°C)
-0.1°C…-1.0°C
(0.6°C)
-0.1°C…-1.0°C
(0.6°C)
-0.1°C…-10.0°C
(3.0°C)
-1°C…-10°C
(3°C)
Differential
While OFF press keep pressed
until word “dt”
appear. Adjust the value by pressing up and down
arrows. Leave the device to return to normal
operation.
Lo
5.0°C…
Hi
(5.0°C)
5.0°C…
Hi
(5.0°C)
5.0°C…
Hi
(5.0°C)
5.0°C…
Hi
(5.0°C)
5.0°C…
Hi
(5.0°C)
-5.0°C…
Hi
(-5.0°C)
-5.0°C…
Hi
(-5°C)
Hi
Lo
…35.0°C
(35.0°C)
Lo
…35.0°C
(35.0°C)
Lo
…35.0°C
(35.0°C)
Lo
…35.0°C
(35.0°C)
Lo
…35.0°C
(35.0°C)
Lo
…90.0°C
(90.0°C)
Lo
…90.0°C
(90.0°C)
Upper and Lower Adjusting Limits
While OFF press and keep pressed POWER, press
,
release POWER, release
. The word “Lo” appears.
Adjust the lower limit by pressing up and down
arrows. Leave the device to return to continue.
The word “Hi” appears. Adjust the upper limit by
pressing up and down arrows. Leave the device to
return to normal operation.
Flo
20.0°C…-60.0°C
(45.0°C)
Maximum Floor Temperature
While OFF press and keep pressed POWER, press
upper button, release POWER, release upper button.
Adjust the value by pressing up and down arrows.
Leave the device to return to normal operation.