www.charltonandjenrick.co.uk
20
LT4636 (ISS 8)
OPTIONAL CABLE FIXING SYSTEM
It is recommended that the appliance be secured to the fireplace
fascia with screws and wall plugs supplied. The cable fixing should
only be used when fixing to 18" openings or when it is desirable
not to drill the fireplace fascia. It may not be possible to use the
cable fixing system with some pre-cast flues.
Drill 4 holes in the rear of the fireplace opening in the
position shown and fix securely the 4 eye bolt with screws
and wall plugs provided.
Fix the fire casing back into the opening using the cable
fixing system as shown do not cut off loose ends of cable
after fixing, coil and tuck carefully into space to the sides
of the burner unit.
Note: When using the cable fixing kit with the spacer, fix and seal
the spacer to the rear of the appliance flange with the screws
and foam seal provided.
Gas Soundness Test
Turn on the gas supply to the appliance ensuring that the
restrictor elbow is fully open and check for soundness in
accordance with current codes of practice.
260mmCRS.
30mm
460mm
FIX 4 OFF EYE
IN POSITIONS
SHOWN
TENSIONING NUT
CLAMP SCREW