24
LT2505 (ISS 13)
REPLACEMENT OF OXY-PILOT ASSEMBLY
NOTE:
If the pilot assembly is replaced it must be replaced by an identical unit from the same manufacturer and
replaced as a complete unit it is a NON SERVICABLE ITEM.
1.
Repeat operations 1-4 for removal of gas control.
2.
Disconnect the pipe from the gas control to the pilot burner
3.
Disconnect the thermocouple connection from the rear of the gas control.
4.
Remove ignition lead from pilot assembly.
5.
Remove the two screws securing the oxy-pilot to the burner.
6.
Before replacing ensure the code number for Oxy-Pilot replacement is suitable.
7.
Re-assemble the in reverse order and check assembly for gas soundness.
8.
Turn on the gas supply, check for gas soundness and recommission appliance.