Charlton & Jenrick PARAGON 2016 Скачать руководство пользователя страница 1

 

 

 

Owner’s Manual 

INCLUDES 

User, Maintenance, Service, and Installation 

Instructions

 

 

PARAGON 2016 & PARAGON 2016 Hi 

 

Keep this booklet for service log and future reference

 

For use in Great Britain and Ireland.

 

Literature NO 2505 (ISS 13) 

IMPORTANT 

 

 

This appliance is guaranteed for 12 months subject to conditions. The 5 year extended parts 

warranty will only be valid if the annual service recommended in this manual has been 

completed and appliance has been registered online. 

Содержание PARAGON 2016

Страница 1: ...ervicelogandfuturereference For use in Great Britain and Ireland Literature NO 2505 ISS 13 IMPORTANT This appliance is guaranteed for 12 months subject to conditions The 5 year extended parts warranty will only be valid if the annual service recommended in this manual has been completed and appliance has been registered online ...

Страница 2: ...checklist This in no way reduces your statutory rights Your warranty commences from the date of purchase and you must retain your receipt or invoice as proof of a purchase date THIS EXTENDED WARRANTY SPECIFICALLY EXCLUDES GLASS AND SOFT REFRACTORY COMPONENTS THE BULB AND ANY BATTERIES Terms and Conditions 1 The appliance must be installed by a GAS SAFE registeredperson 2 The appliance must be used...

Страница 3: ...les All installations must be notified to Local Area Building Control either directly or through a Competent Persons Scheme A Building Regulations Compliance Certificate will then be issued to the customer who should on receipt write the Notification Number on the Benchmark Checklist This product should be serviced regularly to optimise its safety efficiency and performance The service engineer sh...

Страница 4: ...t as proof of purchase This information may be asked for when you contact the helpdesk MODEL PARAGON 2016 Serial No This information can be found on the label attached to the packaging and on the data badge which is located on the base of the appliance behind the control cover Retailer Name Address Date Of Purchase ...

Страница 5: ...nded that it be of the type fitted with a HEPA filter Disposal of refractory ceramic materials To keep dust to a minimum these materials should be securely wrapped in polythene and be clearly labelled RCF waste These materials are not classified as hazardous waste and should be disposed of at a site licensed for the disposal of industrial waste The PARAGON 2016 16 Hi is decorative fuel effect fire...

Страница 6: ... cool for three to four hours before removing debris Rubbish must not be thrown onto the coal bed under any circumstances The cast fire front must be positioned in front of the fire whilst it is burning Pilot Cleaning Before cleaning ensure that the appliance is turned off and cold In some instances you may experience ignition problems even when the appliance is new This may be due to the aeration...

Страница 7: ... tray cover must be greater than 1365mm2 2 12 sq ins SECTION THREE Operation user instructions The appliance Control Panel is positioned behind the fret and carries the control knob The full lighting procedure is as follows 1 Push control knob in as far as possible on gas controls 2 Turn knob anti clockwise until a click is heard The knob will stop at the position marked and a spark should be seen...

Страница 8: ...er the loose components and moulded shapes have been removed Note Dye is available for touching up coal surfaces where the black colouring may have rubbed off in use FUEL BED LAYOUT COAL OPTION Ensure the BASE MATRIX is in position as shown centrally located against the rear edge of the burner outlet Ensure the LEFT SIDE MATRIX is located into the space between the BASE MATRIX and the left hand si...

Страница 9: ...E MATRIX Note it is most important that they are located in their correct positions They are marked on the rear L for LEFT HAND FRONT COAL and R for RIGHT HAND FRONT COAL Slide front support over front edge of fire where the left right front coals meet see below Note the loose coals consist of 11off shaped as coal A 9 off shaped as coal B RH FRONT COAL LH FRONT COAL ...

Страница 10: ...coals as shown so that they rest on the high projections of the BASE MATRIX behind the previous row Lay third row of loose coal 3 off B and 2 off A coals as shown so that they rest on the high projections of the BASE MATRIX behind the previous row Lay last three loose coal 2 off B and 1 off A coal as shown so that they rest over the last two rows of coals as shown A A B B B A A A B B B B A A B B A...

Страница 11: ...ont Pebbles L R Side Pebbles Front Support Number Pebbles Colours as below Pebble identification Coal Numbers Beige Grey 1 2 1 2 4 2 3 1 4 2 3 5 3 5 Total 12 8 In the following instructions the number identification of the pebbles must be followed but the letter shown in brackets is used to identify the pebble colour b for beige or g for grey and this is for guidance only ...

Страница 12: ...nd the right hand side of the fire back with the marking RH go against the right hand inside face of the fire back Locate the LEFT HAND and RIGHT HAND FRONT PEBBLES as shown so that they sit on the front rail and lean back against the BASE MATRIX Note it is most important that they are located in their correct positions They are marked on the rear L for LEFT HAND FRONT PEBBLE and R for RIGHT HAND ...

Страница 13: ...front of the fire as shown A second row numbers positioned toward the rear of fire is place between the base matrix and the rear of the chairbrick as shown Lay a rows of loose pebbles shown Lay another row of loose pebbles as shown Lay the three remaining loose pebbles as shown ...

Страница 14: ...ated into the space between the BASE MATRIX and the right hand side of the fire back with the marking RH go against the right hand inside face of the fire back Locate the LEFT HAND and RIGHT HAND FRONT PEBBLES as shown so that they sit on the front rail and lean back against the BASE MATRIX Note it is most important that they are located in their correct positions They are marked on the rear L for...

Страница 15: ... The recess in the base should locate over shape no 1 and the arrow marked on the base should point towards the rear of the appliance Place driftwood SHAPE No 3 in position as shown The recess in the base should locate over the RH Front Matrix and the arrow marked on the base should point towards the rear of the appliance Place driftwood SHAPE No 4 in position as shown The arrow marked on the base...

Страница 16: ...hown The arrow marked on the base should point towards the rear of the appliance Place driftwood SHAPE No 7 in position as shown The arrow marked on the base should point towards the rear of the appliance Place driftwood SHAPE No 8 in position as shown The recess in the base should locate over shape no 5 and the arrow marked on the base should point towards the rear of the appliance ...

Страница 17: ...nt towards the left hand side of the appliance Place driftwood SHAPE No 10 in position as shown The arrow marked on the base should point towards the rear of the appliance SECTION FIVE Replacement Parts user instructions The only user removable parts are The loose pebbles coals or driftwood The left hand front pebble or coal shape The right hand front pebble or coal shape The right or left hand si...

Страница 18: ...t fret 7kg Gas type G20 Natural G31 Propane Gas Pressure 20 mbar 37mbar PARAGON 2016 PARAGON 2016Hi PARAGON 2016 Gas input Nat Gas Nat Gas PROPANE Max Gross 7 0kW 9 55 kW 7 0kW Min Gross 2 40kW 2 40 kW 2 40kW Injector Main Marked 460 Marked 580 Marked135 Oxy pilot Marked 9040NG Marked 9040NG Marked 9222LPG Data Label Location Swing tab under appliance Gas Connection 8 mm OD Tube 258 00 174 00 14 0...

Страница 19: ...o so could lead to prosecution The PARAGON 2016 is for use ONLY with the GAS STATED ON THE DATA BADGE this may be G20 for Natural Gas or G31 for Propane Gas CHECK YOU HAVE THE CORRECT APPLIANCE FOR THE GAS YOU ARE USING There is not a propane version of the Paragon 2016Hi A non combustible hearth must be provided to comply with the building regulations or a suitable proprietary fire surround with ...

Страница 20: ...room containing the appliance provded normal adventitious room ventilation exists The installer must satify this point by carrying out a mandatory spillage test In the Republic of Ireland permanent ventilation must comply with the rules in force PARAGON 2016 Hi In the United Kingdom requires 11 25cm2 1 8 ins sq purpose built permanent ventilation In the Republic of Ireland permanent ventilation mu...

Страница 21: ...mm from the front face of the surround This is to ensure that no part of the unit with a luminous flame extends beyond the front face of the opening Site the unit as far back as possible whilst maintaining a central position in the opening establish where the fixing holes are to be Having decided the preferred position mark and drill suitable holes use masonry fixing plugs and screws and secure un...

Страница 22: ...erting a lighted smoke match under the top edge of fire opening after the appliance as been burning 10 minutes All the smoke must be drawn into the flue Should spillage still occur examine the chimney for the fault and rectify The test should be carried out with all doors and windows closed If an extractor fan is situated in the room this test should be repeated with the fan running If there is a ...

Страница 23: ...fret 2 Turn off the gas supply by isolating cock and disconnect from the gas supply at inlet elbow 3 Remove all loose fuel bed components 4 Remove 2 lower screws in the front fascia fixing fire unit into the fire opening 5 Disconnect the pipe from the gas control to the main injector 6 Disconnect the supply pipe to the gas control 7 Disconnect the pipe from the gas control to the pilot burner 8 Di...

Страница 24: ... 2 Disconnect the pipe from the gas control to the pilot burner 3 Disconnect the thermocouple connection from the rear of the gas control 4 Remove ignition lead from pilot assembly 5 Remove the two screws securing the oxy pilot to the burner 6 Before replacing ensure the code number for Oxy Pilot replacement is suitable 7 Re assemble the in reverse order and check assembly for gas soundness 8 Turn...

Страница 25: ...www charltonandjenrick co uk 25 LT2505 ISS 13 Register your appliance online today to active your warranty ...

Страница 26: ...ufacturer s instructions Hearth Requirements where fitted Is the hearth constructed from non combustible material Is the hearth a minimum of 12mm thick with a minimum floor to top surface of 50mm BS5871 or as per manufacturer s instructions Is the hearth for open fronted fires a minimum of 760mm wide and has 300mm projecting from the fire opening BS6871 or to manufacturer s instructions Mounting h...

Страница 27: ...ays use the manufacturer s specified spare part when replacing controls SERVICE 01 Date Engineer name Company name Telephone No Gas safe register No Comments Signature SERVICE 02 Date Engineer name Company name Telephone No Gas safe register No Comments Signature SERVICE 03 Date Engineer name Company name Telephone No Gas safe register No Comments Signature SERVICE 04 Date Engineer name Company na...

Страница 28: ...bble Set 2967 Coal Set 2459 Pebble Set 3066 Restrictor Elbow Restrictor Elbow Front Support Front Support Owners Book Owners Book Warning Label Warning Label Serial No Serial No Inspector Inspector Product ID Label 0628 Serial No Prefix BX 0630 CT Burner Tray Box Assembly Driftwood Set 3346 Pebble Set 3066 Restrictor Elbow Front Support Owners Book Warning Label Serial No Inspector ...