P a g e
|
18
Issue No - 4(11/08/21)
Technical Specification
Note: The efficiency of the appliance has been measured as specified in BS EN613:2001 and the
net efficiency rate is 70.6% for natural gas the gross calorific value of the fuel has been used for
this efficiency calculation. Gastec have certified the test data from which it has been
calculated. The efficiency value may be used in the UK Government’s Standard Assessment
Procedure (SAP) for energy rating of the dwelling.
Model
Gas
CAT
Gas
Type
Working
Pressure
Injector
Gas
Input
NOx
Class
Oxy
Pilot
Country
Panache
8040
I
2H
Natural
Gas
20 mbar
Size 075
6.3 KW
Gross
5
2900A
UK
Packaging Check List
1 x Glass Door Assembly
1 x Boxed Fuel Bed
1 x Transformer Plug
1 x Emergency Power Battery Adaptor
1 x RF Handset
4 x AAA 1.5V Batteries
Flue Closure Plate
Flue Spigot