MAINTAINING THE C-POWER

There are no adjustment or maintenance requirements for the C-Power other than cleaning the outside cabinet
with a dry cloth. Periodically have all connections checked by a qualified service person, especially if the boat is
operated in heavy, pounding seas.

TROUBLESHOOTING THE C-POWER

If there is a problem with the C-Power, first check all connections and retest. If all connections are good, see if
the problem is covered in Table 5. If the problem is not covered in Table 5, or if the C-Power still malfunctions af-
ter performing the solution given, contact Charles Marine Products for technical assistance.

Table 5.  Troubleshooting  Suggestions

#

Problem

Solution

1.

The ammeter deflects
in a counterclockwise
direction.

Disconnect the unit immediately. Examine wiring instructions again to assure proper
connections. A movement in a counterclockwise direction or a full-scale movement
indicates excessive current. A wiring error is suspected. A voltmeter can monitor the
voltage when the C-Power is turned on.

2.

Internal red LED on.

The unit is at half-power because the ambient air is too hot. The unit may be at
half-power because the fan is not working. Full power will be restored when the
temperature returns to normal.

WARRANTY & CUSTOMER SERVICE

Warranty

The CHARLES Marine & Industrial Group warrants the unit will be free from defects in materials and workman-
ship that cause mechanical failure for one (1) year, as set forth in the Limited Warranty. Notice of any alleged de-
fect in material or workmanship must be provided within thirty (30) days of discovering the problem, and within the
warranty period. Follow the procedure outlined below to obtain warranty service.

Service Center and Repair Correspondence

Note:

Do not attempt to service the unit. Contact the Service Center.

To contact the Service Center via telephone directly:

800−830−6523 (Toll Free)
217−932−2317 (Voice)
217−932−2473 (FAX)

Call to obtain a Returned Materials Authorization (RMA) number prior to returning any unit to Charles Industries.

Return the unit for repairs to the Service & Repair Center address below:

Charles Industries, Ltd.
Marine & Industrial Group
503 NE 15th Street
Casey, IL 62420-2054
USA

Correspondence can be sent to Corporate Headquarters via the address below:

Note:

Do not return the unit to this address.

Charles Industries, Ltd.
Marine & Industrial Group

Содержание C-Power

Страница 1: ...sue 1 Print 3 1 Charles Industries Ltd All rights reserved Printed in the United States of America C POWERR INSTALLATION INSTRUCTIONS OWNER S MANUAL 12 VDC 24 VDC 15 30 Amp MARINE ELECTRONIC POWER SUP...

Страница 2: ...leaning Precaution 3 Grounding Precautions 3 INSTALLING THE C POWER 4 Choosing Mounting Hardware 4 Mounting the C Power 4 Mounting the Optional Splash Guard 4 Choosing Electrical Wiring Hardware 4 Cho...

Страница 3: ...ty and operating instructions for the C Power Read the entire manual before usage Environmental Precaution Do not expose the C Power to rain snow or excessive moisture C Power Application Precaution T...

Страница 4: ...one side of the mounting hardware half way into the drilled mounting holes 6 Align the mounting slots on the C Power with the secured hardware and slide the C Power s mounting flange under the washers...

Страница 5: ...0V Access to PCB and TB1 TB2 F1 F2 F3 Fuses DC DC LOAD Note 2 Note 3 F3 Figure 1 C Power 15 30 Amp Block Diagram Choosing Wire Gauge Use Table 2 and Table 3 to determine the appropriate wire gauges Av...

Страница 6: ...2 Route the DC wire through the right side access hole on the bottom of the C Power TB2 has one positive terminal and one negative terminal Closing the Access Door Before closing the access door make...

Страница 7: ...turned on 2 Internal red LED on The unit is at half power because the ambient air is too hot The unit may be at half power because the fan is not working Full power will be restored when the temperat...

Страница 8: ...re U S Metric Weight 9 pounds 4 1 kilograms Height 13 25 inches 33 7 centimeters Width 9 5 inches 24 1 centimeters Depth 3 7 inches 9 4 centimeters AC Input 120 VAC nom 220 VAC nom See the label on th...