background image

LT93–PS1230–1

4

 Charles Industries, Ltd. All rights reserved. Printed in the United States of America.

1.

The C-Power should be connected to a metal, grounded, permanent wiring system. An equipment-
grounding conductor should be run with circuit wiring and connected through the C-Power housing
grommets to the equipment grounding (GRN) terminal on the C-Power.

2.

Connections to the C-Power should comply with all local codes and ordinances.

INSTALLING THE C-POWER

Choosing Mounting Hardware

As with any marine equipment, secure mounting is of utmost importance. The bolts or screws used to secure the
C-Power must be 1/4-inch in diameter, backed with a flat washer, and kept vibration-free with a split-ring lock
washer. If using bolts, they must be long enough to be secured on both sides of the bulkhead. If using screws,
they should be at least 1 inch long. All hardware should be corrosion-resistant.

Mounting the C-Power

All corrosion-resistant mounting hardware should be readily available. Follow the steps below to mount the C-
Power to the bulkhead.

Step

Action

1.

Hold the C-Power vertically flush on the bulkhead.

2.

Mark the mounting holes.

3.

Remove the C-Power.

4.

Drill the mounting holes.

5.

Insert one side of the mounting hardware half-way into the drilled mounting holes.

6.

Align the mounting slots on the C-Power with the secured hardware and slide the C-Power’s mounting
flange under the washers.

7.

Insert the mounting hardware for the other side.

8.

Secure all mounting hardware.

Mounting the Optional Splash Guard

If ordered, position and install the optional splash guard (Figure 1) over the C-Power so that the back flange bot-
tom rests on top of the C-Power. This insures proper vertical spacing for ventilation. For optimum splash protec-
tion, be sure to center the splash guard horizontally over the C-Power. Secure with 1/4 inch diameter screws,
approximately 1/2 inch long.

Do not operate this unit without the green wire connected to the CPower and to suitable ground at

shore connection.

DANGER

Note:

Read this manual and all precautions before installing or making connections!

Choosing Electrical Wiring Hardware

The C-Power is intended for hard-wiring in a permanent application. Conduit or other appropriate marine electrical
installation hardware should be used.

Содержание C-Power 93-PS2415

Страница 1: ...PS1230 1 Page 1 of 8 Charles Industries Ltd All rights reserved Printed in the United States of America C POWER INSTALLATION INSTRUCTIONS OWNER S MANUAL 12 VDC 24 VDC 15 30 Amp MARINE ELECTRONIC POWER...

Страница 2: ...ns 3 INSTALLING THE C POWER 4 Choosing Mounting Hardware 4 Mounting the C Power 4 Mounting the Optional Splash Guard 4 Choosing Electrical Wiring Hardware 4 Choosing Wire Gauge 5 Making AC Connections...

Страница 3: ...first then covers installation operation maintenance troubleshooting and warranty and customer service information IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important...

Страница 4: ...bulkhead Step Action 1 Hold the C Power vertically flush on the bulkhead 2 Mark the mounting holes 3 Remove the C Power 4 Drill the mounting holes 5 Insert one side of the mounting hardware half way...

Страница 5: ...s to PCB and TB1 TB2 F1 F2 F3 Fuses DC DC LOAD Note 2 Note 3 F3 Figure 1 C Power 15 30 Amp Block Diagram Choosing Wire Gauge Use Table 2 and Table 3 to determine the appropriate wire gauges Avoid unne...

Страница 6: ...the DC wire through the right side access hole on the bottom of the C Power TB2 has one positive terminal and one negative terminal Closing the Access Door Before closing the access door make sure tha...

Страница 7: ...ature returns to normal WARRANTY CUSTOMER SERVICE Warranty CHARLES MARINE PRODUCTS warrants the C Power will be free from defects in materials and workmanship which cause mechanical failure for one 1...

Страница 8: ...25 inches 33 7 centimeters Width 9 5 inches 24 1 centimeters Depth 3 7 inches 9 4 centimeters AC Input 120 VAC nom 220 VAC nom See the label on the side of the charger for the operating voltage Table...

Отзывы: