Charles 3653-36 Скачать руководство пользователя страница 4

Section 365–336–202

4

The adjusted VF signal is then routed through transformer T2 which provides dc isolation from the line and a bal-
anced output level. The signal is then fed to the T1 & R1 leads (pins 8 and 7) via the LINE and DROP jacks.

4.3

Sealing Current

Three different configurations of Sealing Current are provided and are selected by option Switch S1.

The SX (Simplex) position supplies ground to leads T and R and –48Vdc, through a 750-ohm thermistor, to leads
T1 and R1. When the module is first plugged in, the current surges to approximately 100mA and decreases
quickly to a steady simplex current of approximately 30mA. This low value of dc current being applied to the 4W
cable pairs, on a simplex basis, will break down any resistance film which may build up at nonsoldered splices.
Continued application of this dc sealing current sustains the normal resistance of the cable pairs and prevents
degradation of transmission performance.

In the LP (Loop) position, the simplex leads  of  T1 and T2 are shorted together. Sealing current from the analog
facility will be looped by the channel unit.

The OPN (Open) position is used when no sealing current is required.

XDATA

4W OUTPUT

RANGE +13

TO

-19.5dBm

R 48

T 50

R1 7

T1 8

T-SIG

S11-1

S1-A

LP

SX

OPN

OPN

LP

S1-B

SX

4W INPUT

RANGE

-19.5 TO

+13dBm

PC board connector pin

NOTES:

XXXX

SEALING 

CURRENT

 GENERATOR

T1

T2

RELAY

LB

LOOPBACK

1.
2.
3.
4.

MLB

LB

LINE

DROP

T1&R1

LINE

DROP

T&R

-48V

XMT LEVEL

CONTROL

S2 & S3

FILTER

ENCODER

LB

LOOPBACK

LEVEL

CONTROL

S6

S7

&

LB

RCV LEVEL

CONTROL

S4 & S5

FILTER

DECODER

RDATA

R-SIG

S11-2

DIS

TO

4

20

DIS

LB

S8-1

S8-2

S8-3

TONE

DETECTOR

CIRCUIT

5.

Ganged switches are indicated by alphabeti

cally suffixed reference. Numerical suffix de

notes discrete switch within a package.

N. O., N. C. Relay contact

Frontpanel marking

Signal flow direction

Figure 3.   3653–36 Block Diagram

Содержание 3653-36

Страница 1: ...otice Page 1 of 12 3653 36 4W Transmission Only with Extended Range and Loopback 4W TO ER LB Channel Unit CONTENTS PAGE Part 1 GENERAL 2 Part 2 INSPECTION 2 Part 3 APPLICATION GUIDELINES 3 Part 4 CIRC...

Страница 2: ...es selectable tone loopback disable Prescription adjustable loopback level of up to 31 5dB of gain attenuation in 0 5dB increments Front panel manual loopback switch Front panel mounted bantam jacks f...

Страница 3: ...4 CIRCUIT DESCRIPTION Refer to Figure 3 the 3653 36 block diagram as needed while reading the following circuit description 4 1 Transmit VF Path VF signals applied to the input T R pins 50 and 48 are...

Страница 4: ...s dc sealing current sustains the normal resistance of the cable pairs and prevents degradation of transmission performance In the LP Loop position the simplex leads of T1 and T2 are shorted together...

Страница 5: ...mentarily operated 4 6 7 5 6 Bit or 8 Bit Encoding Decoding The 3653 36 provides 7 5 6 bit or 8 bit encoding and decoding schemes for the transmit and receive paths to from the facility The 7 5 6 bit...

Страница 6: ...d S7 ELL GAIN ATTN Equal Level Loopback Prescription Gain Attenuation Switch S6 is a 6 section DIP switch that provides up to 31 5dB of equal level loopback in 0 5dB steps S7 is a two position slide s...

Страница 7: ...ansmit Alignment in Part 8 Switches S2 and S3 form a 9 section DIP switch that provides up to 32 5dB of attenuation in 0 1dB steps for adjusting the transmit path to the proper operating level at the...

Страница 8: ...t be obtained XMT ATTN TLP 19 5 Use Table 2 for common TLP values For example for a 0 db transmit TLP set the sum of S2 and S3 to 19 5 by placing the switch sections shown be low in the ON position 2...

Страница 9: ...nsmit TLP Values Desired TLP Set S3 S2 Desired TLP Set S3 S2 13 12 11 10 9 8 7 6 5 4 3 2 1 0 5 0 0 5 1 2 32 5 31 5 30 5 29 5 28 5 27 5 26 5 25 5 24 5 23 5 22 5 21 5 20 5 20 19 5 19 18 5 17 5 3 4 5 6 7...

Страница 10: ...act Charles Industries Ltd for replacement or repair instructions or follow the Repair Service Procedure below 11 3 Advanced Replacement Service In Warranty Units Charles Industries Ltd offers an adva...

Страница 11: ...Underwriters Laboratories Standard 1459 Second Edition Compliance is re stricted to inside plant wiring Field repairs may void compliance b FCC P 15 Class A c Meets Canadian CSA and DOC requirements...

Страница 12: ...back l DETECTOR FREQUENCY Will detect within 2713 7Hz will not detect outside of 2713 35Hz m DETECTOR AMPLITUDE Will detect 0 0 to 30dBm0 will not detect less than 40dBm0 n DETECTOR TIMING Activate 2...

Отзывы: