Section 365–336–202
12
Table 4. Frequency Response
FREQ (Hz)
XMT (dB)
RCV (dB)
60
Less than –14.0
––––––––
200
+0.15 to –2.0
+0.15 to –1.0
300
+0.15 to –0.15
+0.15 to –0.15
1000
0 (REF)
0 (REF)
3000
+0.15 to –0.15
+0.15 to –0.15
3400
0 to –1.5
0 to –1.5
4000
Less than –14.0
Less than –14.0
(j) CROSSTALK: 61dBm0 minimum at 400Hz; 71dBm0 minimum at 700Hz to 1KHz; 70dBm0 minimum
at 3kHz.
(k) LEVEL TRACKING SINGLE-ENDED AT 1020Hz: +0.25dB from +3 to –37dBm0, +0.5dB from –38 to
–50dBm0.
12.2.3. Loopback
(l) DETECTOR FREQUENCY: Will detect within 2713 + 7Hz; will not detect outside of 2713 + 35Hz.
(m) DETECTOR AMPLITUDE: Will detect 0.0 to –30dBm0; will not detect less than –40dBm0.
(n) DETECTOR TIMING: Activate, 2.2 seconds; deactivate, 1.1 seconds.
(o) ELL GAIN/ATTENUATION RANGE: 0.0 to 31.5dB in 0.5dB increments.
12.3
Physical Specifications
The physical characteristics of the 3653–36 4W are shown in Table 5.
Table 5.
Physical Specifications
Feature
U.S.
Metric
Height
4.25 inches
10.8 centimeters
Width
1.31 inches
3.3 centimeters
Depth
10.31 inches
26.2 centimeters
Weight
9.25 ounces
263 grams
Temperature
32 to 122
F
0 to 50
C
Humidity
To 95% (no condensation)