background image

Section 365–262–205

14

Option

Function/Remarks

Position

W
(3652

W1

Condition the E2-lead to go idle then busy after 2.5 seconds during a carrier failure

(3652–
62 only)

W2

Condition the E2-lead to go busy during a carrier failure

62 only)

W3

Condition the E2-lead to go idle during a carrier failure

Y
(3652–

OPEN

Balanced contact closure between the 1-lead and 2-lead

(3652–
68 only) CLOSED

Switched ground output on the 1-lead and a ground on the 2-lead

Z
(3–way
push on
jumper)

Z1

Tandem mode — M-lead conditioning
Busy M-lead:

Battery

Idle M-lead:

Open (screw option ZC open)
Ground (screw option ZC closed)

Z2

E&M mode — E-lead conditioning
Type I/III E&M Signaling Interface (EB grounded)

Z3

E&M mode - E-lead conditioning
Type II Signaling Interface (E and EB dry contact)
Busy E-lead:

E and EB shorted

Idle E-lead: 

E and EB open

ZC

OPEN

Normal mode E-lead signaling (open for idle)

CLOSED

Tandem mode M-lead signaling (ground for idle)

FC
(3652–

OPEN

E2-lead signaling (open for idle)

(3652–
62 only) CLOSED

E2-lead signaling (ground for idle)

8.

ALIGNMENT

8.1

Transmit Alignment

The XMT PRESCRIPTION GAIN switches (half of S4 and half of S5) are used together to provide up to 32.5dB
of prescription gain in increments of 0.1dB to accommodate an input TLP range from +10.0 to –22.5dBm. To ad-
just the transmit path to the proper operating level, the difference b10.0 and the transmit TLP at T&R
must be obtained.

[XMT GAIN = (+10.0) –TLP]

For an input TLP of –22.5dBm, the XMT GAIN = (+10.0) - (–22.5) = 32.5dB. Set the sum of the switch settings on
S4–5 through S4–8 and S5–6 through S5–10 to 32.5.

8.2

Receive Alignment

The RCV PRESCRIPTION GAIN switches (half of S4 and half of S5) are used together to provide up to 32.5dB
of prescription gain in increments of 0.1dB to accommodate an output TLP range from +10.0 to –22.5dBm. To
adjust the receive path to the proper operating level, the difference between the receive TLP at T1&R1 and –22.5
must be obtained.

[RCV GAIN = TLP – (–22.5)]

For an output of TLP of –16.0dBm, the RCV GAIN = (–16.0) - (–22.5) = 6.5dB. Set the sum of the switch settings
on S4–1 through S4–4 and S5–1 through S5–5 to 6.5.

9.

TESTING

After completing Parts 4 through 8, place a call end-to-end through the facility to verify proper operation. If trouble
is encountered, recheck all installer connections, options and alignment settings, and verify that the channel unit
is making positive connection to the backplane connector. If trouble persists, replace the unit with a similar unit
known to be in proper operating order and retest the facility. Channel unit testing for fault diagnosis or verification
of circuit operation is provided in Section 360–001–205.

Содержание 3652-62

Страница 1: ...it 3652 68 4 Wire E M with PLR and ER Channel Unit Complies with UL Standard 1459 Second Edition 3652 68 Only CONTENTS PAGE Part 1 GENERAL 2 Part 2 INSPECTION 3 Part 3 APPLICATION GUIDELINES 3 Part 4...

Страница 2: ...editorial update 1 3 Equipment Function 1 4 Equipment Location Mounting Occupies one channel unit slot of a Charles Industries 360 363 D4 Digital Carrier Terminal 1 5 Equipment Features The 4W E M PLR...

Страница 3: ...protective bags with uncoated cartons for shipping or storage of channel units CAUTION 3 APPLICATION GUIDELINES The 4W E M PLR channel units allow versatility for use in many applications These units...

Страница 4: ...Z Z2 ZC OPEN FC OPEN E2 M2 E2 M2 360 363 D4 TERMINAL 360 363 D4 TERMINAL OPTION SETTINGS OPTION SETTINGS Figure 4 Typical Tandem FX Application DETECTOR M LEAD DETECTOR TRUNK CIRCUIT 4W E M 3652 XX M...

Страница 5: ...TECTOR circuit 4 3 1 E M Signaling Transmit In E M signaling an off hook condition battery on the M lead is applied to the M LEAD DETECTOR circuit via the NORM BUSY switch This causes a logic 1 state...

Страница 6: ...1 N2 NOTE 19 M1 M2 M3 NORM NOTE 21 XMT PRESCRIPTION GAIN 0 T0 32 5dB IN 0 1dB STEPS RCV TLP 5 2dBm NORM BUSY DROP LINE E M DROP LINE BUSY X 1 PC board connector pin 2 Primary transmission path 3 Signa...

Страница 7: ...XMT PRESCRIPTION GAIN 0 T0 32 5dB IN 0 1dB STEPS RCV TLP 5 2dBm NORM BUSY DROP LINE E M DROP LINE BUSY X 1 PC board connector pin 2 Primary transmission path 3 Signal flow direction 4 Front panel mar...

Страница 8: ...owing functions Disconnect M lead E lead in tandem mode from the office equipment Turn on BUSY LED on front edge of units Applies a busy condition on the E lead M lead for tandem mode to the office eq...

Страница 9: ...unit is removed from its mounting slot the E lead Pin 4 and the E2 lead Pin 2 are grounded through a shorting contact in the backplane connector A busy condition is transmitted to both far end E lead...

Страница 10: ...the state of the E lead sent toward the trunk circuit during a carrier failure One of three trunk processing modes can be selected E lead to transmit an idle state then change to a busy state 2 5 sec...

Страница 11: ...umper over the appropriate pins within that option grouping to obtain the desired operation 7 1 Switch S1 NORM BUSY Place the NORM BUSY switch to the NORM position to condition the channel unit for no...

Страница 12: ...e M2 lead and send a busy condition to the far end 7 7 Push On Jumper Option P1 P2 P3 E Lead Conditioning and W1 W2 W3 E2 Lead Conditioning 3652 62 Only Trunk Processing During a Carrier Failure To co...

Страница 13: ...V position S4 ON or OFF Provide up to 1 5dB of gain to the transmit and receive path when all the switches of S4 are ON S5 ON or OFF Provide up to 32 5dB of gain to the transmit and receive path when...

Страница 14: ...ccommodate an input TLP range from 10 0 to 22 5dBm To ad just the transmit path to the proper operating level the difference between 10 0 and the transmit TLP at T R must be obtained XMT GAIN 10 0 TLP...

Страница 15: ...e the unit will be shipped in the fastest manner consistent with the urgency of the situa tion In most cases there are no charges for in warranty repairs except for the transportation charges of the u...

Страница 16: ...LEVELS Transmit fixed 5 2dBm TLP receive fixed 5 2dBm TLP d DROP SIDE LEVELS Transmit input 22 5dBm minimum 10 0dBm maximum receive output 22 5dBm minimum 10 0dBm maximum e 1000Hz GAIN Transmit fixed...

Страница 17: ...ion Ratio dB 0 to 30dBm0 35 minimum 40dBm0 29 minimum 45dBm0 25 minimum r TLP RANGES Transmit 22 5 to 10dBm receive 22 5 to 10dBm s OPERATING ENVIRONMENT Temperature 32 to 122 F 0 to 50 C 12 1 2 Elect...

Отзывы: