background image

Section 365-001-201

11

12.

SPECIFICATIONS

12.1

Electrical (Single-Ended)

(a) Transmit input TLP range: –9.5 to +7 dBm

(b) Receive output TLP range: –10.5 to +6 dBm

(c) Transmit prescription attenuation: 0 to 16.5 dB in increments of 0.1 dB

(d) Receive prescription attenuation: 0 to 16.5 dB in increments of 0.1 dB

(e) Transmit and receive port impedance: 3650–01, 900 ohms + 2.15 uF; 3650–02, 600 ohms + 2.15 uF

(f) Transmit and receive path frequency response (referenced at 1kHz):

Frequency (Hz)

XMT (dB)

RCV (dB)

60

–20 minimum

200

–2.5 to 0

–1.5 to 0

300

–0.49 to +0.24

–0.49 to +0.24

1000

0 (ref)

0 (ref)

3000

–0.49 to +0.24

–0.49 to +0.24

3400

0 to –1.2

0 to –1.2

4000

–14 minimum

–14 minimum

5100

–32 minimum

–32 minimum

(g) Longitudinal balance: –62 dB or less at 200 Hz to 1 kHz; –60 dB or less at 3 kHz

(h) Signal to distortion ratio: 35 dB minimum at 0 to –30 dBm0; 29 dB minimum at –40 dBm0; 25 dB

minimum at –45 dBm0

(i) Trans-hybrid loss: Echo return loss, 36 dB minimum; singing return loss, 25 dB minimum; singing re-

turn loss high, 32 dB minimum

(j) Return loss: Echo return loss, 35 dB minimum; singing return loss, 23 dB minimum; singing return

loss high, 32 dB minimum

(k) Transmit/receive idle channel noise: 20 dBrnC0 maximum

(l) Crosstalk: 61 dBm0 minimum at 400 Hz, 71 dBm0 minimum at 700 Hz to 1 kHz, 70 dBm0 minimum

at 3 kHz

(m) Level tracking (measured single-ended at 1010 Hz): +/–0.25 dB from +3 to –37 dBm0, +/–0.5 dB

from –38 to –50 dBm0

Содержание 3650-01

Страница 1: ...ein subject to change without notice Page 1 of 12 3650 01 03 2 Wire Equalized Transmission Only Channel Units with Lead Conditioning 2W ETO w LC CONTENTS PAGE Part 1 GENERAL 2 Part 2 INSPECTION 2 Part...

Страница 2: ...brid balancing compromise network of 2 15 uF in series with 900 ohms 3650 01 or 600 ohms 3650 03 Built in jack J3 to mount an optional 3690 00 10 compromise network subassembly or an optional 3690 01...

Страница 3: ...n 4 CIRCUIT DESCRIPTION Refer to the block diagram in Figure 3 while reading the following circuit description 4 1 Transmit VF Path VF signals applied to the input tip and ring leads pins 50 and 48 ar...

Страница 4: ...Section 365 001 201 4 Figure 3 Block Diagram...

Страница 5: ...coding close option YC 10 Coil type test point 22 Screw options AC BC and JC are used to provide sealing cur rent Close Option Open Option Function AC BC JC Supply sealing current to the loop JC AC BC...

Страница 6: ...es and connector to verify proper alignment and the absence of foreign material CAUTION Use the following steps to mount the unit Step Action 1 Align the channel unit with the appropriate card guided...

Страница 7: ...acing all of the jumpers in the OUT position results in 0 dB attenuation 7 5 RCV Attenuation push on jumpers Eight push on jumpers select up to 16 5 dB attenuation in 0 1 dB increments for adjusting t...

Страница 8: ...ttenuation when all jumpers are in the IN position See part 7 5 A Set to the OPEN position if jack J3 is equipped or if an external PBN BOC is used Open Closed AC BC JC For external sealing current at...

Страница 9: ...t TLP range from 6 to 10 5 dBm To adjust the receive path to the proper operating level the difference between 6 and the receive TLP at T1 and R1 must be obtained RCV ATTN 6 TLP For an output TLP of 1...

Страница 10: ...n the out of service unit in the carton in which the replacement was shipped using the pre addressed shipping label provided Call your customer service representative at the telephone number above for...

Страница 11: ...0 49 to 0 24 3400 0 to 1 2 0 to 1 2 4000 14 minimum 14 minimum 5100 32 minimum 32 minimum g Longitudinal balance 62 dB or less at 200 Hz to 1 kHz 60 dB or less at 3 kHz h Signal to distortion ratio 3...

Страница 12: ...cifications are shown in Table 3 Table 3 Physical Specifications Feature U S Metric Height 4 2 inches 10 6 centimeters Width 1 35 inches 3 4 centimeters Depth 10 3 inches 26 7 centimeters Weight 16 ou...

Отзывы: