Section 360-880-202

12

1. All channel units are busied or idled

2. A yellow alarm (AY) condition is sent to the WEST transmit facility (if CM2 or CM3 is selected, a yel-

low alarm is not sent)

3. An AIS signal is sent to the EAST transmit facility on all unassigned channels going between EAST

and secondary

4. The alarm relay for the WEST AR and AY is activated

Trunk processing will end approximately 15 seconds (1 second for CM2, immediately for CM3) after detection of

no AR alarm condition.
When the WEST receive facility receives a yellow alarm condition from a distant terminal, the unit will declare a

yellow alarm and illuminate the AY LED after detecting this condition for approximately 480 ms. At this time, the

unit will begin its trunk processing routine that will:

1. Busy or idle all channel units

2. Send AIS code to the EAST transmit facility

3. Activate the alarm relay for the West AR and AY

Trunk processing will end approximately 30 ms after detection of no yellow alarm.
When a red alarm (AR) is detected on the East facility, a yellow alarm (AY) is sent back on the East facility. If a

yellow alarm is detected on the east facility, no other action is taken. Red or yellow alarms detected on the East

facility will illuminate the respective AR and/or AY LEDs. When the red alarm condition no longer exists for

approximately 15 seconds, the yellow alarm signal will stop being sent. If no yellow or red alarm conditions are

detected, the LEDs will turn off.

4.8

Loopbacks

The ST1U provides three different types of loopbacks. All of the far-end loopbacks require a remote control link

between the near-end and far-end 360-80s. The line near-end loops the data back toward the customer of drop-

side. Far-end loopbacks can be either payload or line. The far-end payload loopback will loopback only the time

slots in the T1, but not the framing. The far-end line loopback will loopback all timeslots and the framing of the T1.

The card also responds to all standard CSU and T1 loopback codes.

5.

INSTALLATION

5.1

Installing the Unit

The ST1U installs in the secondary T1 slot of the 360-80. See Figure 14 for a sample of the shelf layout.

Multichannel Unit

Multichannel Unit

Primary T1 Controller (T1-S)

(channels 13−24)

(channels 1−12)

(channels 25

30)

Multichannel Unit

or Secondary T1

Unit

Figure 14.  

360-80 ICB Common Equipment Configuration

5.1.1. Attaching the Rear Panel

The rear panel of the unit should be installed before the unit is installed in the shelf, and before wiring begins.

Содержание 3608-80 Secondary T1

Страница 1: ...subject to change without notice Page 1 of 18 3608 80 Secondary T1 Unit CONTENTS PAGE Part 1 GENERAL 2 Part 2 INSPECTION 3 Part 3 APPLICATION GUIDELINES 4 Part 4 CIRCUIT DESCRIPTION 7 Part 5 INSTALLA...

Страница 2: ...ependent T1 loop timing dual T1 mode only Transport Protection switching protection mode only Drop and re insert operation with bypass normal D RI mode only Front panel status LEDs Front panel T1 moni...

Страница 3: ...tion Red AR Alarm Status LED Yellow AY Alarm Status LED Loss of frame LOF Alarm Status Loss of signal LOS Alarm Status Power status LED T1 framing selected Line code Trunk processing TP status LED Lin...

Страница 4: ...and the T1 of the ST1U to be connected to two different 360 80 ICBs These two T1s run independently of each other and allow the 360 80 system to provide up to 1 5 Mbps to each T1 for a total of over...

Страница 5: ...switch to the protection mode See Figure 4 for a typical configuration Note Both T1 S units should be set for the same error threshold 360 80 Primary T1 360 80 T1 Protection T1 S ST1U T1 S ST1U Figure...

Страница 6: ...Re Insert 8 channels west and 8 channels east Drop Re Insert 16 channels Terminate 360 80 ICB 360 80 ICB 360 80 ICB A B C West East Site 1 Site 2 8 channels west Figure 6 Drop and Re Insert Applicati...

Страница 7: ...lay path for the T1 facility as part of the assembly as shown in Figure 8 When de energized these relays bypass the ICB and connect the WEST primary T1 to the EAST secondary T1 When the ST1U and T1 S...

Страница 8: ...des monitor jacks to monitor this T1 The T1 then goes to the EAST TIMING and FRAMING block where the circuit detects either SF or ESF framing A loss of framing signal will cause the AR LED to light an...

Страница 9: ...stalled card will be allocated to phantom channels These timeslots must be de allocated before they can be allocated to a channel When a different card is inserted into a chassis slot that had timeslo...

Страница 10: ...serted between the channel and the same timeslot of the other T1 Primary Secondary W D I E Time Slot Mode has No Effect on Data in Both Directions Figure 10 Drop at T1 Primary and Secondary for the Sa...

Страница 11: ...ass Through because when both primary and secondary timeslot modes are set to broadcast the data passes through the 360 80 Primary Secondary W D I E Controlled by Secondary TS Mode Controlled by Prima...

Страница 12: ...no other action is taken Red or yellow alarms detected on the East facility will illuminate the respective AR and or AY LEDs When the red alarm condition no longer exists for approximately 15 seconds...

Страница 13: ...tem 6 After the self test is performed check the software provisioning of the unit using either the front panel craft interface on the front of the controller unit or the network management interface...

Страница 14: ...ible indications of present alarm conditions it does NOT clear the alarm If a new alarm occurs the audible indication will re enable Table 1 LED Definitions Label Color Indicates that POWER Green The...

Страница 15: ...ction Line Near End Line Far End Payload Far End None Remote Control Method None Occupy One Channel Facility Data Link ESF Format Only Facility Data Link Bypass Drop and Re insert Only Auto Bypass For...

Страница 16: ...arton in which the replacement was shipped using the pre addressed shipping label provided Call your customer service representative at the telephone number above for more details 9 4 Standard Repair...

Страница 17: ...to monitor the secondary T1 signal both transmit and receive without interference Alarm interface and contacts The system provides visual and audible alarm contact clo sure when the channel bank is i...

Страница 18: ...3 Physical Specifications Feature U S Metric Height 0 75 inch 1 9 centimeters Width 5 64 inches 14 32 centimeters Depth 9 25 inches 23 49 centimeters Weight 0 64 pound 290 grams Temperature 40 to 149...

Отзывы: