26
OCPP 7.4kW
OCPP 22kW
HOME (all)
Rated V/-10%
Rated Current
Connector Type (62196-2)
Configurable Current in Amp
(from app)
Rated Frequency
Protection Rating
Residual Current detection
RCCB
MCB
Temperature Protection
*RCCB type A or B can be required to match local law requirements. ALWAYS verify with your local installer
**A second RCCB CA 30ma must be installed before station even if internal RCCB is installed. Type B residual
current monitor is optional on WB132H/WB332H and inclued in all other models
Remote Power configuration
Scheduled Charging configuration
Locking
Charging Statistics (Weekly and Monthly)
Pause / Restart
Load Balancing / Solar Balancing / live power monitoring
Maximum power settings
Statistics (only if connected via Wi-Fi)
Live Monitoring (Voltages, Temps, Amps)
Work with Bluetooth or Wi-Fi. Only one working mode at time
is possible
220V/240V(1P)-400v(3P)
32A
Type 2
6-8-10-13-16-20-25-32
(from app)
50Hz/60Hz
IP55
Opt (H series) - CC 6ma(P
Series)*/**
(from app)
No (required)
220V/240V
32A
Type2
6-8-10-13-16-20-25-32
(from app)
50Hz/60Hz
IP55
CC 6 mA**
(from app)
No (required)
Yes, stop over 65°
400V
32A
Type2
6-8-10-13-16-20-25-32
(from app)
50Hz/60Hz
IP55
CC 6 mA**
(from app)
No (required)
Yes, stop over 65°
Electrical Specifications
APP Features Android / iOS