Main screen5:PD communication monitor
screen
Menu button
Switch between monitor or sniff mode
Left|Right button
Switch to other main screen
Monitor
Monitor mode(default) only monitor data
packets on CC wires,
if CC wires doesn’t
connect will cause
Intermittent power failure
Sniffer
Sniff mode , automatic sent handshake packet
when press button,
can change SRC Fixed
Supply PDO
CC1、CC2
The CC wire current used for communication,
automatic change
Source Cap
Source or Sink
packet of PD communication
protocol
Request
Upper layer requests to change to a different
power supply from Source.
We send a new REQUEST message to the
Source and the upper layer can start using the
new power supply
5.050V 3.001A
CC1
5.00V 3.0A
9.00V 3.0A
15.0V 2.0A
Monitor
Source Cap
5.050V 3.001A
CC2
5.00V 3.0A
9.00V 3.0A
15.0V 2.0A
20.0V 1.5A
Sniffer
Request
2.00/2.00A
Main screen6:About Logo Help information
Menu button
click enter
System Setting
screen
Left|Right button
Switch to other main screen
Website
My blog website ,can
obtain more help information
Copyright (C) 2017
LYSstudio Vision 1.0
www.chargerlab.com
System setting1:Screen parameters
Menu button
Switch to next screen
Left|Right button
①Change screen brightness level ②Open
screen saver mode ③Standby time
Brightness
Screen brightness, step 5 range from 0 to 100
Saver
Screen saver mode
Sleep
Standby time, for example enter standby
mode 1 hours later, still measure
Screen
Brightness
60
Saver
OFF
Sleep 1 hours
System setting3:Calibration parameters
Menu button
Switch to next screen
Left|Right button
①Adjust reference voltage ②One key
calibrate ③Manual adjust gain
VBUS
Voltage measured
VREF
Reference voltage input , need very precise
voltage source
AUTO CAL
Press right/+ for one key calibrate
ZERO
Press right/+ for one key set current to 0
AMPS
Current of output load
Calibration
VBUS
:
10.0000
VREF
:
10.0002
AUTO CAL
R
GAIN
:
1.00018
Calibration
ZERO
:
0.0000 R
IREF
:
2.4999
AUTO CAL
R
GAIN
:
1.00001
System setting3:FactoryReset parameters
Menu button
Switch to next screen
Left|Right button
Press right/+ restore reference data and
system settings to factory preset
FactoryReset
Warning...
Erase all data
R