background image

WARNING

If 

“growing”

 bubbles appear, do not use or move the LP 

cylinder. Contact an LP gas supplier or your fire department!

2.

Turn all control knobs to the OFF position.

ck

w

o

l

is

C

e

f

f

O

Do not use a POL transport 
plug (plastic part with external 
threads)! It will defeat the 
safety feature of the valve.

6.

Turn the coupling nut clockwise and tighten to a full stop. The

regulator will seal on the back-check feature in the LP cylinder
valve, resulting in some resistance. 

An additional one-half to

three-quarters turn is required to complete the
connection. Tighten by hand only – do not use tools.

NOTE:

If you cannot complete the connection, disconnect regulator
and repeat steps 5 and 6. If you are still unable to complete the
connection, 

do not use this regulator!

DANGER

• Do not insert any tool or foreign object into the valve outlet or

safety relief valve. You may damage the valve and cause a
leak. Leaking propane may result in explosion, fire, severe
personal injury, or death.

LP Cylinder Leak Test

For your safety

Leak test must be repeated each time LP cylinder is

exchanged or refilled.

Do not smoke during leak test.

Do not use an open flame to check for gas leaks.

Grill must be leak tested outdoors in a well-ventilated area,

away from ignition sources such as gas fired or electrical
appliances. During leak test, keep grill away from open flames
or sparks.

•Use a clean paintbrush and a 50/50 mild soap and water

solution. Brush soapy solution onto areas indicated by arrows in
figure below.

Do not use household cleaning agents.

 Damage to gas train

components can result.

5.

Hold regulator and insert nipple into LP

cylinder valve. Hand-tighten the coupling
nut, holding regulator in a straight line with
LP cylinder valve so as not to cross-thread
the connection.

4.

Remove the safety cap from LP cylinder valve. Always use cap

and strap if supplied with valve.

3.

Turn LP cylinder OFF by turning hand-wheel clockwise to a 

full

stop

.

1.

LP cylinder must be properly secured onto grill. (Refer to

assembly section.)

Connecting Regulator to the LP Cylinder

Straig

ht

Hold coupling nut and regulator 
as shown for proper connection 
to LP cylinder valve.

Coupling nut

Nipple has to be 
centered into the LP 
cylinder valve.

Safety Relief 
Valve

OPD Hand 
Wheel

Type 1 outlet 

with thread 

on outside

Strap and Cap

5

Содержание PERFORMANCE 468640017N1

Страница 1: ...as proof of purchase date For customer service in New Zealand contact Aber Holdings Ltd via Telephone 080016116 Email service aber co nz www aber co nz For use with propane gas only For Outdoor Use On...

Страница 2: ...APPLY i AT LEAST 25 OF THE TOTAL WALL AREA IS COMPLETELY OPEN AND ii AT LEAST 30 OF THE REMAINING WALL AREA IS OPEN AND UNRESTRICTED IN THE CASE OF BALCONIES AT LEAST 20 OF THE TOTAL OF THE SIDE BACK...

Страница 3: ...Symbols The symbols and boxes shown below explain what each heading means Read and follow all of the messages found throughout the manual DANGER If you smell gas 1 Shut off gas to the appliance if pos...

Страница 4: ...r barbecue must meet the following requirements Use gas cylinders only with these required measurements 30 5 cm diameter x 45 7 cm tall with 9 kg capacity maximum Gas cylinder must be arranged for vap...

Страница 5: ...ime LP cylinder is exchanged or refilled Do not smoke during leak test Do not use an open flame to check for gas leaks Grill must be leak tested outdoors in a well ventilated area away from ignition s...

Страница 6: ...ls inside the appliance trolley enclosure that would block the flow of combustion air to the underside of either the control panel or the firebox bowl DO NOT disconnect or change gas container within...

Страница 7: ...alves Hose and Regulator Leak test before first use at least once a year and every time the cylinder is changed or disconnected 1 Turn all appliance control knobs to 2 Be sure regulator is tightly con...

Страница 8: ...h use Baked on grease deposits may require the use of an abrasive plastic cleaning pad Use only in direction of brushed finish to avoid damage Do not use abrasive pad on areas with graphics Cooking su...

Страница 9: ...o appliance store outdoors in a well ventilated space and out of reach of children Cover appliance if stored outdoors Store appliance indoors ONLY if gas cylinder is turned off and disconnected remove...

Страница 10: ...Name Gas Barbecue Total Nominal Heat Input 19 0 MJ Hr Gas Category I3B P 30 Model No 468640017NZ Gas Type Gas Pressure 2 75 kPa Injector Size Dia mm Barbecue 0 78 x 2 pcs Destination Countries NZ Elec...

Страница 11: ...se costs themselves 7 Pickup and delivery of your product 8 Repairs to parts or systems resulting from unauthorized modi cations made to the product 9 The removal and or reinstallation of your product...

Страница 12: ...PARTS LIST 468640017N1 12...

Страница 13: ...PARTS DIAGRAM 13 54...

Страница 14: ...J H C B F L E Black Black Black 14...

Страница 15: ...G L L L L L L L 15...

Страница 16: ...K K K K K K K K 16...

Страница 17: ...Note remove the tie wraps x4 L L L L L 4 17...

Страница 18: ...B B B B B B 5 6 18...

Страница 19: ...C J C C J J 7 19...

Страница 20: ...L L L L L L L L L 8 20...

Страница 21: ...9 10 21...

Страница 22: ...35 34 11 12 22...

Страница 23: ...13 14 53 AA Battery Not included 4TH 20 23...

Страница 24: ...F F F 15 24...

Страница 25: ...H H 16 25...

Страница 26: ...Leak test before first use at least once per year and every time the gas cylinder is changed or disconnected 17 26...

Страница 27: ...Inspect your infrared grate before each use to ensure that the openings are not covered with debris See the Grilling Guide for detailed cleaning instructions 27...

Страница 28: ...cylinder and visually inspect rubber seal in cylinder valve for damage If damage or cannot correct leak replace cylinder See LP Cylinder Leak Test and Connecting Regulator to the LP Cylinder Turn off...

Страница 29: ...ng stem match fireplace match See Match Lighting section of Use and Care Check for gas in LP cylinder Turn off control and tank knobs wait 30 seconds turn tank knob on slowly light grill If flames are...

Страница 30: ...lex com Phones 032 245 0550 545 0550 Website www grillex com ua Thailand Parts Store Co Ltd Ph 034 426 403 Email partsstore2012 gmail com 118 55 M 1 Rama2Road Tumbon Ta Jeen Muang Samutsakorn Samutsak...

Страница 31: ...ebsite www aber co nz Brasil Silvano Carlos Duarte ME Ph 19 3573 8899 Email silvano charbroil com br Peru TDP Corp Ph 659 5959 Email servicioalcliente tdpcorp com pe Website www tdpcorp com pe Japan I...

Страница 32: ...For customer service in New Zealand contact Aber Holdings Ltd via Telephone 080016116 Email service aber co nz www aber co nz...

Отзывы: