Problem
Burner(s) will not light
using ignitor.
(See Electronic Ignition
Troubleshooting also)
Burner(s) will not
match light.
Sudden drop in gas
flow or low flame.
Flames blow out.
Flare-up.
Persistent grease fire.
Flashback...
(fire in burner tube(s)).
Unable to fill LP
cylinder.
One burner does not
light from other
burner(s).
Possible Cause
ELECTRONIC IGNITION:
• No spark, no ignition noise.
• No spark, some ignition noise.
• Sparks, but not at electrode or at full
strength.
• See
“GAS ISSUES:”
on previous page.
• Match will not reach.
• Improper method of match-lighting.
• Out of gas.
• Excess flow valve tripped.
• Vapor lock at coupling nut/LP cylinder
connection.
• High or gusting winds.
• Low on LP gas.
• Excess flow valve tripped.
• Grease buildup.
• Excessive fat in meat.
• Excessive cooking temperature.
• Grease trapped by food buildup around
burner system.
• Burner and/or burner tubes are blocked.
• Some dealers have older fill nozzles
with worn threads.
• Grease buildup or food particles in
end(s) of carryover tube(s).
Prevention/Solution
• See Section I of Electronic Ignition System.
• See Section II of Electronic Ignition System.
• See Section III of Electronic Ignition System.
• Use long-stem match (fireplace match).
• See “Match-Lighting” section of Use and Care.
• Check for gas in LP cylinder.
• Turn off knobs, wait 30 seconds and light grill. If flames are still low,
turn off knobs and LP cylinder valve. Disconnect regulator.
Reconnect regulator and leak-test. Turn on LP cylinder valve, wait
30 seconds and then light grill.
• Turn off knobs and LP cylinder valve. Disconnect coupling nut from
cylinder. Reconnect and retry.
• Turn front of grill to face wind or increase flame height.
• Refill LP cylinder.
• Refer to “Sudden drop in gas flow” above.
• Clean burners and inside of grill/firebox.
• Trim fat from meat before grilling.
• Adjust (lower) temperature accordingly.
• Turn knobs to OFF. Turn gas off at LP cylinder. Leave lid in position
and let fire burn out. After grill cools, remove and clean all parts.
• Turn knobs to OFF. Clean burner and/or burner tubes. See burner
cleaning section of Use and Care.
• The worn nozzles don’t have enough “bite” to engage the valve. Try
a second LP dealer.
• Clean carry-over tube(s) with wire brush.
AUTO-CLEAN™
Possible Cause
Prevention/Solution
(If Equipped)
?
Replace Batteries
?
Install batteries correctly.
?
Push Knob in to start the clean cycle. (Green LED should begin to
flash)
Timer does not work
(Green light does not
flash)
?
Dead Battery
?
Batteries installed incorrectly.
?
Knob Position did not start the Clean
Cycle
?
Replace Batteries
No LED’s will illuminate
?
Dead Battery
?
Prepare to replace batteries (NOTE: Clean cycle will operate with a
weak battery.
Red LED next to battery
symbol is illuminated
?
Low Battery Strength
27